BPM and Profile Monitor Alignment - PowerPoint PPT Presentation

1 / 11
About This Presentation
Title:

BPM and Profile Monitor Alignment

Description:

Profile Monitor Alignment ... BPM's have 4 alignment holes, know electric cener w/rt center defined by these holes. SAG aligns cylinders of BPM's relative to ... – PowerPoint PPT presentation

Number of Views:136
Avg rating:3.0/5.0
Slides: 12
Provided by: dha143
Category:

less

Transcript and Presenter's Notes

Title: BPM and Profile Monitor Alignment


1
BPM and Profile Monitor Alignment
  • Debbie Harris in consultation with
  • Wes Smart
  • Peter Prieto
  • Virgil Bocean

2
NuMI Beamline Convention
  • A Device should report the signed distance of the
    actual beam with respect to the ideal beam.
  • For NUMI Beam left positive x (as you look
    downstream)
  • For NUMI Beam Up positive y
  • Note This is not a universal convention!!!

3
Profile Monitor Alignment
  • Correction needed to get from center of foil
    plane (half-way between the middle two files,
    defined as monitor center) to the ideal beam
    position
  • Profile Monitors in MI area (PM101-PM112) havent
    moved since December
  • Others may have
  • moved
  • February Alignment
  • constants
  • ADD these numbers to
  • position relative to monitor
  • center to get position w/rt
  • ideal beam position

4
BPM Alignment
  • Remember how BPM works beam goes through BPM,
    induces charge on two plates

5
Electric Center Measurement
  • Electric center location where when particle
    goes through, charge induced on two plates are
    equal
  • Measured by Jim Fitzpatrick on test stand4
    orientations, take the sum
  • This offset is measured relative to physical
    center as defined by alignment holes
  • So imagine to induce equal charge, beam is 1mm in
    positive direction want that to be zero!
  • Have to subtract this offset but they are usually
    very small usually lt.1mm, 5 are .1-.3mm

6
Physical Offset w/rt Ideal Beam
  • BPMs have 4 alignment holes, know electric cener
    w/rt center defined by these holes
  • SAG aligns cylinders of BPMs relative to ideal
    beam position
  • SAG measures in beamine positions of cylinders
    w/rt Ideal Beam
  • SAG measures (in village) center w/rt cylinder
  • If beam goes through center w/rt holes of BPM,
    want it to tell you how far that center is from
    ideal beam ADD this correction! (same as PMs)

7
Electronic Offset
  • Forget the BPM what happens if you put equal
    charge into the cables that go the electronics,
    what position does electronics read back? This
    can be due to phase differences, cable lengths,
    etc.
  • You want electronics to return 0mm if it gets
    equal charge as input subtract what you measure
    when you put in equal charge!
  • These can be large (up to 1.5mm!)

8
What offsets were on when?
  • In December and January, electronic offsets were
    in, but not the others. The others (summarized in
    table at right) are to be added
  • BUT only MI area ones are sure to be exactly
    correct

9
What happened for most of Feb. Run?
  • Physical and Electric offsets were in right, but
    electronic offsets were in with the wrong sign
    (added, not subtracted). So to get to the right
    position for up to 2PM Feb.22, have to subtract
    2 electronic offset

HPTGT correction -1.4mm!
10
So what did the beam look like for stable running
at that point?
  • PM105 off by many wires!
  • HTGT also off from 0
  • (from E-log, 20 Feb)

11
What happened when BPM entries were corrected
(2/22, 1300-1400)?
  • Autotune was run, which tries to set all bpm
    readbacks to 0. BUT cant change position at
    injection, so not all BPMs did read back 0.
  • PMs much closer to 0 than they were before, and
    also much closer to BPMs than previously.
Write a Comment
User Comments (0)
About PowerShow.com