Title: BPM and Profile Monitor Alignment and Calibration
1BPM and Profile Monitor Alignment and Calibration
- Debbie Harris in consultation with
- Wes Smart
- Peter Prieto
- Virgil Bocean
- Zarko Pavlovich
2NuMI Beamline Convention
- A Device should report the signed distance of the
actual beam with respect to the ideal beam. - For NUMI Beam left positive x (as you look
downstream) - For NUMI Beam Up positive y
- Note This is not a universal convention!!!
3Profile Monitor Alignment
- Correction needed to get from center of foil
plane (half-way between the middle two files,
defined as monitor center) to the ideal beam
position - Profile Monitors in MI area (PM101-PM112) havent
moved since December - Others may have
- moved
- February Alignment
- constants
- ADD these numbers to
- position relative to monitor
- center to get position w/rt
- ideal beam position
4BPM Alignment
- Remember how BPM works beam goes through BPM,
induces charge on two plates
- BPM Offsets that need to be applied
- Electronic Offsets
- Electric Center Offset
- Alignment Offset
5Electric Center Measurement
- Electric center location where when particle
goes through, charge induced on two plates are
equal - Measured by Jim Fitzpatrick on test stand4
orientations, take the average - This average is relative to physical center as
defined by alignment holes - So imagine to induce equal charge, beam is 1mm in
positive direction want that to be zero! - Have to subtract this offset but they are usually
very small usually lt.1mm, 5 are .1-.3mm
6Physical Offset w/rt Ideal Beam
- BPMs have 4 alignment holes, know electric cener
w/rt center defined by these holes - SAG aligns cylinders of BPMs relative to ideal
beam position - SAG measures in beamine positions of cylinders
w/rt Ideal Beam - SAG measures (in village) center w/rt cylinder
- If beam goes through center w/rt holes of BPM,
want it to tell you how far that center is from
ideal beam ADD this correction! (same as PMs)
7Electronic Offset
- Forget the BPM what happens if you put equal
charge into the cables that go the electronics,
what position does electronics read back? This
can be due to phase differences, cable lengths,
etc. - You want electronics to return 0mm if it gets
equal charge as input subtract what you measure
when you put in equal charge! - These can be large (up to 1.5mm!)
8What offsets were on when?
- In December and January, electronic offsets were
in, but not the others. The others (summarized in
table at right) are to be added - BUT only MI area ones are sure to be exactly
correct
9What happens when you have 2 measurements of the
same thing
- Although there are 23 BPMs (1 view each) and 10
profile monitors (1 view each) there are only 13
positions where we have two measurements of the
same quantity - Note 4 downstream BPMs, right before target,
are all redundant with profile monitors
Next Slides consider only the 13 redundant
pairs of measurements
10Comparison of Corrections
BPM True value measured value electronic
offset BPM Offset (BPM offset
includes electric center correction) Profile
Monitor True Value measured value PM Offset
11With all known corrections in, how well do BPM
and PMs Agree?
12What could be wrong here?
- Virgil has done other measurements of the
electric centers which disagree with Jim
Fitzgeralds electric center measurements by a
factor of 10!
Mount If BPM is up or down
13Still to do
- Understand how Virgils measurements could be
discrepant by such a huge factor - Keep going through various offsets and
corrections with fine-toothed comb
14What happened for most of Feb. Run?
- Physical and Electric offsets were in right, but
electronic offsets were in with the wrong sign
(added, not subtracted). So to get to the right
position for up to 2PM Feb.22, have to subtract
2 electronic offset
HPTGT correction -1.4mm!
15So what did the beam look like for stable running
at that point?
- PM105 off by many wires!
- HTGT also off from 0
- (from E-log, 20 Feb)
16What happened when BPM entries were corrected
(2/22, 1300-1400)?
- Autotune was run, which tries to set all bpm
readbacks to 0. BUT cant change position at
injection, so not all BPMs did read back 0. - PMs much closer to 0 than they were before, and
also much closer to BPMs than previously.