Preparing for Insertion
  • Have the client wash her entire arm (one she uses
    less often).
  • Cover the procedure table and arm support with a
    clean cloth.
  • Ask client to lie on her back so that implant arm
    is turned outwards and bent at the elbow and is
    well supported.
  • Prepare clean instrument tray, open sterile
    instrument pack.
  • For Jadelle and Sino-Implant (II), carefully open
    sterile pouch containing implants by pulling
    apart, without touching the rods, allowing them
    to fall into a sterile cup or bowl.
  • For Implanon, remove the sterile applicator with
    the preloaded implant by allowing it to fall on
    the sterile tray.

3
Before Insertion
  • Wash hands with antiseptic soap and water, dry
    with clean towel or air-dry.
  • Put sterile or high-level disinfected (HLD)
    gloves on both hands before procedure.
  • Clean insertion site with a cotton soaked in
    antiseptic solution and held in a sterile or HLD
    forceps.
  • Use sterile surgical drape with a hole to cover
    arm. Hole should be large enough to expose entire
    area where implants will lie.
  • When giving local anesthetic, use a new
    disposable syringe and needle, if available, an
    autodisable syringe is preferable.

4
During Insertion Jadelle and Sino-Implant
  • To minimize risk of infection and/or expulsion,
    make sure ends of rods nearest to the incision
    are not too close (not less than 5 mm) to
    incision. If tip of rod is too close to the
    incision, it should be carefully removed and
    reinserted. To enable easy removal of both rods
    from a single incision, it is important that ends
    of rods closest to the incision are not farther
    apart, than the width (not length) of one
    implant.
  • While inserting implants, try not to remove
    trocar from incision. Keeping trocar in place
    minimizes tissue trauma, decreases chances of
    infection, and minimizes insertion time.

5
During Insertion Implanon
  • After confirming rod is in applicator, remove
    needle shield.
  • Without needle shield, implant can fall out, so
    keep applicator in upright position until
    insertion.
  • If it falls out or if contamination occurs, use a
    new package.

6
After Insertion
  • Clean around insertion site with antiseptic.
  • Cover insertion site with bandage and cover with
    gauze.
  • Dispose of applicator, syringe and needle in
    sharps container. Burn or bury when ¾ full.
  • Decontaminate non-disposable instruments in 0.5
    chlorine for 10 minutes.
  • Dispose of contaminated items like gauze, cotton,
    etc. in leak-proof container or plastic bag.