Title: Salient Green features of Benchmark
1Infinity Benchmark A LEED Green Building
- Salient Green features of Benchmark
- High performance glass
- Rain water harvesting
- Eco friendly Energy efficient equipment
- systems
- Consumes 25 less energy
- Water efficient flow flush fixtures
- Consumes 40 less water
- Insulated roof
- Roof garden Under deck insulation
- Building Management System
- Better controls monitoring
- Enhanced fresh air quantity
- Better comfort productivity
Infinity Benchmark - Kolkata
2Building Envelope
- External walls and roof have high insulation
property - External walls made of brick wall block with 4
inch expanded polystyrene insulation ACP
cladding - U-factor 0.073 Btu/hr.ft2
- Roof has under deck insulation with 30 mm of
rigid polyurethane foam - Terrace garden on roof top reduces heat island
effect - Use of overhangs on selected facades reduces the
direct solar gains through glazing. - High performance glazing catering to 36 of
total building facade
Infinity Benchmark - Kolkata
3High Performance Glazing
- Double glazed glass units increase energy
efficiency of building - Less heat ingress into the building
- Better transmission of day light into occupied
spaces - Provides external connectivity to occupants
- Use of overhangs on selected facades reduced
direct solar gain through glazing - Glass characteristics
- 1. U Value 2.64 W/m2 K
- 2. Solar heat gain coefficient 0.2
- 3.Visual Light transmittance-0.23
Infinity Benchmark - Kolkata
4Eco-Friendly Energy Efficient Equipment
- Consume 25 less energy
- CFC free refrigerant to avoid ozone depletion
- HVAC equipment has been designed with no
compromise on human comfort levels - Energy efficient water cooled chillers with CoP
value of 6.3 - Primary secondary chilled water pumps with
variable speed drive to economize pump energy
Infinity Benchmark - Kolkata
5Building Management System
- Optimized energy consumption resulting in
operational energy savings of 15-20 - Typical examples of energy saving through BMS
integration - Night time purging to cool the building
- Chiller management
- Controlling AHU fan speed and chilled water pumps
based on heat loads - Temperature, humidity and lighting control
- Monitors and controls indoor comfort condition
- Automatically monitors amount of fresh air that
enters the spaces - Can also track occupancy status of each zone and
accordingly adjust fresh air flow - Provides alarm systems so as to take corrective
actions
BMS Screen
Infinity Benchmark - Kolkata
6Efficient Lighting
- Use of energy efficient fluorescent lamps (T5s)
and luminaries with high coefficient of
utilization - The interior lighting designed with overall
lighting power density less than 1.0 Watts per sq
ft - Minimized light trespass from the site to
increase night sky access and improve night time
visibility - External lighting designed to reduce the
development impact on nocturnal environments
Infinity Benchmark - Kolkata
7Water Efficient Fixtures
- Consume 40 less water
- Water efficient flow flush fixtures are used in
the entire building - Reduces burden on municipal water supply and
waste water systems - Reuse of storm water and
- treated grey water for non-potable applications
such as toilet, flushing and irrigation
Infinity Benchmark - Kolkata
8Eco-Friendly Vehicle Charging
- Provision of 13 electric car charging points
- Reduces pollution and land development impacts
from automobile use - Costeffective and environment friendly means for
commuting to work
Infinity Benchmark - Kolkata
9 Indoor Environmental Quality
- Occupants provided with superior indoor air
quality through energy efficient HVAC equipment - Air conditioned spaces are maintained at 24 oC
and 50 - 60 relative humidity through out the
operation of building - CO2 levels and fresh air quantities are
continuously monitored and maintained at a
pre-determined value to enhance the productivity
of the occupants - Adhesives, sealants, paints, resins used in the
common areas have low volatile organic compound
(VOC) content - Day lighting views enhance productivity of
occupants
Infinity Benchmark - Kolkata
10Building Materials
- Use of construction materials having 20 recycled
content and 20 locally available - Use of recycled materials reduced the impacts
resulting from extraction and processing of new
virgin materials - Illustrative list of materials with recycled
content - 1. False ceiling material made of industrial
waste - gypsum - 2. Door panels made of bagasse
- 3. Aluminium door and window frames have high
recycled Aluminium content - Use of 100 FSC certified wood for all wooden
components
Infinity Benchmark - Kolkata
11Waste Collection Segregation
- Reduction of building waste diversion to
landfills - An easily accessible area in each floor is
dedicated to the collection and storage of non
hazardous materials - Separation of dry waste and wet waste materials
at source - Segregation and storage of dry wastes such as
paper, cardboard, glass, plastics and metals to
facilitate recycling
Infinity Benchmark - Kolkata