NEXTChem Process Analyzers, Inc.
2
NEXTChem Process Analyzers, Inc.
  • NEXTChem is located in Chicago, IL U.S.A.
  • Our Mission is to build, support and continuously
    improve the Best Process Analyzers in the World!

3
NEXTChem Process Analyzers, Inc.
What makes NEXTChem Analyzers different?
  • Sampling never requires a filter, decreasing
    maintenance and increasing reliability
  • Modern electronics makes programming through the
    User-Interface very simple
  • Using the latest innovations in stepper motor
    control for precise chemical analyses
  • Combining Multiple Chemical Analyses with
    Multiple Sample Streams within a single unit
  • Chemical Measurements with Process Control in a
    single unit

4
Types of Measurement Techniques
NEXTChem Process Analyzers, Inc.
  • Titration Endpoint Determination
  • (sulfite in sea water)
  • Standard Addition Ion Selective Electrodes
  • (ammonia in wastewater)

5
Titration Curve Response vs. Concentration
At the point of maximum change in sensor response
(endpoint) the sample concentration is zero!
6
Typical Titration Curve
The reagent additions are controlled by distance
from endpoint for maximum accuracy.
7
Types of Titrations
NEXTChem Process Analyzers, Inc.
  • Acid / Base -Acetic Acid
  • Redox -Sulfide
  • Complexation -Cyanide
  • Precipitation -Chloride
  • Color -Hardness

8
Three Types of Ion Selective Electrodes
Solid State Membrane The membrane is an
insoluble crystal of the ion to be
determined. Example Fluoride, Silver/Sulfide,
Chlorine Gas Permeable Membrane A gas permeable
membrane separates the sample from the sensor,
commonly pH electrode. Example Ammonia, Carbon
Dioxide Neutral Carrier Membrane The membrane
contains an ion specific complexing
agent. Example Nitrate, Potassium
9
The characteristics of the ISE are described by
the Nernst equation
The Nernst equation
E E0 RT ln(10) log (c) nF
E Offset Slope . log (c)
10
Example of Standard Addition Curve
Response due to Sample
Response due To Spike
Calibration
11
Color Measurements
Color Dip Probe is used for the measurement 630
nm Red, 590 nm Yellow, 520 nm Green, and 470 nm
Blue The following analyses can be done with the
color measurements Total Hardness, Calcium
Hardness, Phosphate, Manganese (II) and Zinc
12
NEXTChem Process Analyzers, Inc.
OMNIChem Advanced 12 Chemical Analyses / 8
Sample Points (industrial) OMNIChem Basic 8
Chemical Analyses / 4 Sample Points
(industrial) MINIChem Plus 4 Chemical Analyses /
4 Sample Points (industrial/municipal) MINIChem 2
Chemical Analyses / 2 Sample Points
(municipal)
13
NEXTChem Process Analyzers, Inc.
HANDYChem 4 Chemical Analyses / 4 Sample Points
(industrial/municipal) ECOChem 2 Chemical
Analyses / 2 Sample Points (municipal)
14
Many Analyses Available
Ammonia (NH3), Nitrate (NO3-), Sulfide
(H2S) (Wastewater) Sulfite (SO3-2), Chlorine
(Cl2) (Petroleum) Acetic Acid (CH3COOH),
Nitric Acid (HNO3) (Chemical) Hardness (Mg2
Ca2), Fluoride (F-) (Drinking Water) Hydroxide
Peroxide (H2O2), Caustic (NaOH) (Textile) F/T
Acid (H3PO4), F/T Alkalinity (H2CO3) (Metal
Finishing) Copper (Cu2), Silver (Ag), Cyanide
(CN-) (Mining) Ozone (O3), ABC Analysis
(S-2/NaOH/CO3-2) (Pulp/Paper) NEXTChem
specializes in automating Wet Chemical Analyses!
15
Examples of some Industrial Experiences
City of Fort Wayne alkalinity / pH Clean Water
Services ammonia / alkalinity China
Petroleum cyanide Eastman Chemical acetic acid
hardness Procter Gamble alkalinity /
hardness Bosch high level chlorine Medtronic
low level cyanide Duke Energy high level
hardness Saudi Aramco sulfite/pH in sea
water
16
Industrial Experiences
Robert Bosch Wiper Systems Tienen,
Belgium Customers Sample 2.40 g/L chlorine
(Cl2) in water (very corrosive) Measurement
every 10 minutes Accuracy 0.2 relative
standard deviation
17
Industrial Experiences
Saudi Aramco Dammam, Saudi Arabia Customers
Sample 50 ppm Sulfite (SO3-) in sea water
Measurement every 10 minutes Accuracy 0.2
relative standard deviation
18
Measurement Cell
Non Dilution Measurement Cell
Dilution Measurement Cell
19
Sample Systems
Sample Systems Micro Dilution 0.25 mL - 2.00
mL (lt0.1mm particles) Standard Dilution 5.0 mL
- 30.0 mL (lt2mm particles) Standard
Non-Dilution 90 / 140 mL (lt3mm
particles) Self-Cleaning Non-Dilution 90 / 140
mL (lt6mm particles) All Sample Systems are
available for all OMNIChem/MINIChem and
HANDYChem/ECOChem series analyzers.
20
Self-Cleaning Sample Valve
This valve makes sampling lt 6mm particles
possible. Most common use is in sewage plants.
21
Standard Non-Dilution Sample System
  • Used with Clean and Low Concentration Samples
  • Commonly used in Drinking Water/Final Effluent
    Applications

22
Sample Panel Materials
Standard Dilution Sample System
  • Teflon FEP tubing used in sample panel
    construction
  • PVDF is be used for the valve bodies and fittings
  • Commonly used in Metal Finishing Plants

23
Sample Panel Materials
Micro-Dilution Sample System
Used with very clean and very high concentration
samples. All wetted surfaces PEEK or
Teflon Commonly used in the Semiconductor
Industry and Chemical Plants
24
Modern Electronics
Why use 1980s electronics found in most on-line
analyzers, when you can have modern electronics?
25
Modern Electronics
100 MHz CPU - Hitachi SH3 Series 7708 PC / 32
bit processor 4 MB ROM 2 MB RAM Modbus
RTU Touchscreen Interface Unicode/ASCII Up to
57K baud serial communication
26
Modern Electronics
Modbus is standard on all NEXTChem
Analyzers. Additional Industrial Networks
Available Profibus DP DeviceNet CANopen Control
Net LonWorks CC Link FIPIO Phone Modems and
Radio Modems can also be added
27
What does E-Automation Really Mean?
The analyzer is assigned an IP address and
connected to the plant network. All the screens
on the touch screen are available and
interactive, making remote changes
possible. Installed at Eastman Chemical in
Kingsport, TN USA.
28
International Considerations
Multi-Language HMI Universal Power Supply
110/220VAC 50/60Hz
29
Touchscreen Languages Available
  • English is the Primary Language
  • The customer selects the second language
  • Spanish español
  • Portuguese portuguese
  • French français
  • Dutch nederlands
  • Arabic ????????
  • Russian ??????
  • Italian italiano
  • Chinese ?
  • Only MINIChem/OMNIChem Interfaces are Bi-Lingual
  • Spanish is the default second language

30
Easy to use touchscreen !
  • NO MORE PUSH BUTTONS!
  • Bright Backlight makes the User Interface easy to
    read

31
Precision Reagent Pump
  • 7.500 mL stroke volume
  • Accuracy 0.001 mL
  • Kalrez Seal for long life (1 year)
  • Communications confirmed with each movement
  • Pump failures detected within one refill cycle
  • Stepper Motor with 8335 steps/mL or
  • 0.00012 mL/step

32
Corrosive Environments
  • NEMA 4X (IP66) Fiberglass
  • Enclosure
  • Either a Z-Purge, X-Purge, or
  • ATEX-Purge can be supplied
  • Z-Purge (Class 1 Div 2)
  • X-Purge (Class 1 Div 1)
  • ATEX-Purge (Zone 2)

33
Rugged Electronics
  • Circuit Breaker for the Power Inlet
  • Power Filter for the main power in 110 VAC or
    220 VAC
  • Fuses 5mm x 20mm for all internal/external
    devices
  • All analog inputs have 1.5 kV isolation
  • All analog outputs can have 1.5 kV isolation
  • Industrial Relays with diode protection and easy
    to replace

34
Dynamic Electrode Output Display
  • Electrode measurements are displayed during each
  • analysis
  • This information is invaluable in determining if
    the
  • analyzer is operating correctly at a glance