Title: Regulation on Industrial Discharge to Public Sewer
1 Regulation on Industrial Discharge to Public
Sewer
Kinji YAMADA JSWA
2Objective
- Protection of structural integrity drainage
performance of public sewer - Permit compliance of effluent from WWTP to Water
Pollution Control Law
3Demarcation of regulation
Factory
Responsibility of wastewater utility
Sewer (ex, chemical effect)
WWTP.
Effluent (ex, negative impact)
4Regulates for factories
- Water pollution control law and Sewage law
- 1.Notification
- 2.Pretreatment to meet discharge permit to sewer
5Regulates for factories
- Notification
- Type of designated factories
- Installation of pretreatment
- Water quality control administrator
- Emergency Reporting
6Types of designated factories
- Designation in WPCL
- mining, livestock, drink food production
- laundry, paper industry, fertilizer
manufacture - organic-chemical industry, petrochemical-
industry, leather business, metal working
industry, plating industry - WTP, WWTP, Solid waste disposal
7Notifications
Designated factories
Registration as designated factories
Undesignated factories
Registration by pretreatment
8Discharge permit to public sewer
- Discharge quality need to comply to permit
stimulated by sewage law and local ordinance - If violation is expected, installation of
pretreatment facility mandatory at factories - If violations are found, warning letters are
issued before penalty.
942 Quality parameters for permit
Classification Substance
Heavy metals Cd Pb As Hg Cr Cu Zn Fe, etc
Organics DXN PCB TCE PCE, etc
Inorganics CN F B, etc
general BOD n-hex SS N P pH Temp, etc
10Monitoring and supervision
- Among registered factories, inspection priority
is given to factories using harmful substances. - If violation found, instruction given for
correction
11Record of Monitoring Supervision in Tokyo, 2011
Notification 8,770
Inspection 5,982
Sampling 2,985
Warning letters 387
12Certificated water quality control administrator
- Improve self-control of factories
- Awareness
- Technology
- Leading to better factory discharge quality
- Certification by seminar attendance
- Nationally certification pollution control
administrator
13Afterword
- This presentation was made to visitors from St.
Petersburg. - The content is based on the authors work
experience at Tokyo Metropolitan Gov. and its
publication. - For more information, email info_at_gcus.jp