ACTIVA ROOFTOP 45-90kW - PowerPoint PPT Presentation

1 / 25
About This Presentation
Title:

ACTIVA ROOFTOP 45-90kW

Description:

ELECTRICAL BOX. AIR FILTERS. EVAPORATING SECTION. Outdoor Air. ReturnAir. Upper. View. SupplyAir. ... ACCESSORIES . available. Product Deployment Introduction ... – PowerPoint PPT presentation

Number of Views:99
Avg rating:3.0/5.0
Slides: 26
Provided by: bul45
Category:

less

Transcript and Presenter's Notes

Title: ACTIVA ROOFTOP 45-90kW


1
ACTIVA ROOFTOP 45-90kW
Product Presentation
2
Contents
  • Customer Value Proposition
  • ACTIVA rooftops at a glance
  • Construction Details
  • Features benefits
  • New Option Accessories
  • Competition Comparison
  • Documentation
  • Future Strategy

3
Customer value proposition
  • The new ACTIVA rooftops come to cover our
    customer needs, as they use R410A refrigerant,
    are better performing than existing units, and
    incorporate many new features which are more and
    more demanded in the market.

4
ACTIVA rooftops at a glance
  • Main Advantages Features
  • R410A Refrigerant
  • Improved efficiency and low noise level
  • Tandem configuration (up to 52ºC with 1 comp.)
  • New models HP Gas
  • Sizes 45 -60-75-90 kW
  • New PCB YKN2Open (JCI protocol)
  • New options and accessories
  • Energy recovery
  • Return fan
  • F6, F7 filters as options G4 as std pre-filter

100 Compatible with existing roofcurbs(suituable
for JCI Rooftop replacement)
5
Construction Details
Upper View
Isometric View
ELECTRICAL BOX
AR_ 45/60
EVAPORATING SECTION
CONDENSING SECTION
AIR FILTERS
  • AR_ 75/90

Outdoor Air
ReturnAir
SupplyAir
6
Construction Details
  • Serviceability

Pressure gauges
Charge valves
7
Features Benefits
  • TANDEM CIRCUIT
  • Possibility to work at partial load
  • Higher efficiencies when working at partial load
  • Higher lock-out temperatures (up to 52º
    whenworking at partial load)
  • Less piping components
  • Cost Saving

8
Features Benefits
New Board and control YKN2Open
  • Auto restart and Random start
  • Last 10 lockouts stored in a non-volatile memory
  • Compressors runtime priority
  • Lockout and Incident level of protections
  • Reset the lockout from thermostat
  • Unique defrost strategy with coil dry cycle
    included
  • 4 stages Hot water coil with minimum supply air
    temp

9
Features Benefits
  • New quiet outdoor fan with external bell to
    reduce air turbulences and sound level while
    increasing efficiency

10
Features Benefits
  • SAFETY FEATURES

- Liquid line filter-dryer - Discharge
temperature cut-off switch - - Suction
accumulator (on heat pumps) - Liquid sight
glasses - Crankcase heater
- High and low pressure switches - Suction line
antifreeze thermostat
11
Features Benefits
  • DPC-1 Sensors

12
Features Benefits
Full range of OPTIONS ACCESSORIES available
13
New Options AccessoriesENERGY RECOVERY
  • Energy Recovery The concept

14
New Options AccessoriesENERGY RECOVERY
Energy Recovery in ACTIVA
15
New Options AccessoriesENERGY RECOVERY
  • Energy Recovery in ACTIVA
  • Enthalpy wheel
  • Energy recover for sensible and latent heat (?
    75)
  • Wheel material imbedded in matrix (Silica gel)
  • Casing made in stainless steel.
  • Permanently lubricated bearings 20 years
    lifetime min!
  • Easy to clean
  • Airflow adjustment in installation

16
New Options AccessoriesENERGY RECOVERY
  • Energy Recovery Most commonly used technologies

Total energy recovered (kWh)
Heat Pipe
Active Recovery
Energy needs
Entalphy Wheel
Plate ex-changer
Water Glycol
17
New Options AccessoriesRETURN FAN
  • Return Fan EC plug technology with backguard
    blades
  • Automatic fan speed control through EC
    Technology
  • More efficient
  • Quiet operation (no magnetic noise)
  • Differential pressure sensors to automatically
    adjust the airflow to the setting point
  • Compact design
  • Easy installation and set up
  • Soft start
  • Motor protection included
  • Counterrotating flaps to release excess of
    pressure

18
New Options AccessoriesRETURN FAN
Return fan Why EC?
19
New Options AccessoriesAIR FILTERING
Gravimetric efficiencyAm()
Filter Class
Opacimetric efficiencyEm()
As per EN 779
Delivered as standard
Available as Option for Rooftop and Heat Recovery
20
Competitors Comparison
  • Source Eurovent

21
Competitors Comparison
Source Eurovent
22
Documentation
  • Technical Documentation
  • New look, easy to read, with more detailed user
    information, installation instructions and tech
    specs, supported by more pictures, Warnings,
    potential risks and safety advices.
  • Delivered wit the unit 4 separate documents
    CD
  • Generalities Describes a short Introduction to
    the product, unit identification, Plate
    descriptions (serial number and rating plate), CE
    Declaration and manufacturer contact.
  • User Guide Description of the unit, operation
    instructions, troubleshooting, maintenanceAvaila
    ble in 6 languages.
  • Quick Installation Guide Detailed information
    that will drive you through the installation
    process (placement, duct connection and
    electrical wiring)Available in 6 languages
  • CD ROM Installation Contains info on how to
    install the CD.
  • CD ROM Contains above mentioned information
    Full
    installation guide (including technical data)

    All options and accessories
    instructions in all 6 languages
  • Available languages EN ES FR GR IT - NL

23
Documentation
  • Technical Documentation
  • Quick installation guide includes 4 pages to be
    used as a checklist for commissioning and write
    down installed data.

24
Future and Strategy
  • Current ACTIVA models will be complemented with
    the rest of Rooftop product family, upgraded to
    R410 Refrigerant
  • Small rooftops (up to 40kW) will be launched end
    of 2010. Same features as ACTIVA and
  • 1 new size 17 kW
  • Compact design
  • Inverter supply fan
  • IP54 as an option
  • Large Rooftops (up to 180 kW) will be launched
    summer 2011 with same features as ACTIVA and
  • 2 new sizes 100 180 kW (Range 100, 120, 150
    180 kW)
  • Complete new cabinet new distribution
  • Inverter supply fan

25
THANKS FOR YOUR ATTENTION