A better understanding of Solar SSR - PowerPoint PPT Presentation

1 / 26
About This Presentation
Title:

A better understanding of Solar SSR

Description:

A better understanding of Solar SSR Solar Building Integrated Photovoltaic (BIPV) for Standing Seam AND Exposed Fastener Roof Systems – PowerPoint PPT presentation

Number of Views:180
Avg rating:3.0/5.0
Slides: 27
Provided by: employee
Category:

less

Transcript and Presenter's Notes

Title: A better understanding of Solar SSR


1
A better understanding of Solar SSR
Solar Building Integrated Photovoltaic (BIPV)
for Standing Seam AND Exposed Fastener Roof
Systems
2
  • The Solar SSR System
  • Total system working together to harvest power
  • Standing seam applications
  • Exposed fastener applications
  • System sizes
  • System costs
  • Fabrals offering

3
Total System
On grid system is shown Off grid systems
require battery storage between DC Disconnect and
Inverter
4
The Total System Working together to harvest
power.
  • Triple-junction technology captures three wave
    lengths (red, green/yellow and blue) of sunlight
  • Panels are electrically daisy-chained together to
    maximize output
  • Power is converted from DC to AC and is
    returned to the grid
  • Optional Data Acquisition System provides
    real-time analysis of energy production

5
The Total System
  • The Solar SSR panels are
  • Highly flexible, lightweight and durable
  • More efficient at producing electricity than
    alternative polycrystalline solar technology,
    especially in shadows and/or low light
  • Efficient up to 185F
  • A peel and stick back

6
The Total System
  • No roof penetrations to install
  • Eliminates additional structural support
    requirements
  • Maintains serviceability and walkability of the
    roof
  • Roof slopes between 112 and 2112
  • Curving is permitted
  • Tested to very high hail and wind resistance
    ratings extremely durable
  • Extremely light weight at 0.75 psf

7
Standing Seam Applications
  • Can be applied to existing metal roofs or new
    standing seam panels
  • Standing Seam panels must be at least 16 seam to
    seam
  • Fabral Enduracote and Flurobond paint systems
    are approved
  • Solar SSR panels are field installed can be
    adhered prior or post to installing standing seam
    panels

8
Standing Seam Panel profile options
Architectural/Commercial
Post Frame/Residential
9
Exposed Fastener Applications -A PATENT PENDING
APPLICATION -
  • BIVP solar thin film laminates can be adhered to
    hemmed flat sheets that are one foot longer than
    the solar panels
  • Flat sheets are then attached over exposed
    fastener systems

10
Solar Panels on Grandrib 3Note panels shown
much shorter than actual length to get all
details on drawing
11
Solar Panels on Grandrib 3 PV Wires Under Ridge
Cap
12
Transparent Drawing Showing Wires Under Ridge Cap
Solar Panels on Grandrib 3
13
Baffling Material Under Flat Plate
Solar Panels on Grandrib 3
14
System Sizes
  • Wide range of power sizes to choose from,
    depending upon budget and building requirements.
  • Standard system sizes 1.5, 3, 5, 10, 15, 30, 60,
    120 and 240 Kw
  • The system requires approximately 600 s.f. for 3
    kW

15
Watts?
Watt Unit of power Volt x Amp Watt Hour
Unit of energy equal to 1 watt of power operating
for one hour. 1,000 W (watt) 1 kW (Kilowatt)
5kW system x 1hour 5 kW-h Average 3.5-4 hours
a day of 100 efficiency Average day5kW system
x 3.8 hours 18 kW-h / Day
18kW-h will light 7.5 100w light bulbs for 24
hours
16
Typical Power Production Percentages
  • Commercial buildings 11.7 17.4 kWh per sq.ft.
    floor area
  • Residential buildings Average house uses 11,000
    kWh per year
  • 5kW system produces approximately 5,000 8,000
    kWh per year
  • 1.5kW Pennsylvania 2,020 kWh / yr
  • 3kW Virginia 4,077 kWh / yr
  • 5kW Washington 6,389 kWh / yr
  • 5kW N. Carolina 6,939 kWh / yr
  • 5kW N. Carolina 7,201 kWh / yr
  • 5kW Pennsylvania 6,753 kWh / yr
  • 10kW Wisconsin 12,155 kWh / yr
  • 15kw Wisconsin 18,215 kWh / yr

17
Solar SSR
Other Factors
  • Azimuth angle (direction the roof faces, SE, S,
    SW, etc)
  • South or SW is often considered the best
  • Sunlight
  • Shade
  • Snow cover
  • Module/Panel Width 15.5 PV width
  • 16 SSR most efficient
  • 18 20 SSR wasted space

18
What Fabral Sells
  • Fabral sells
  • Solar SSR panels
  • Cable Trays
  • Cable Tray Covers
  • Rubber Grommets
  • S-5! Mini Clamps
  • Our customers must obtain the other components
    themselves
  • We provide suggested manufacturers and contacts
    to call

19
System Costs
  • Total estimated system price
  • (less the metal roof)
  • 3kw (rated DC, 3.264kw) 25,786
  • 5kw (rated DC, 5.44kw) 41,344

20
Installation
  • Metal panels must be clean and smooth with no
    stiffening ribs, striations or embossing
  • Thin-film solar laminate is adhered directly onto
    the exposed face of the SSR panel in the field or
    shop in temperatures between 50 and 100F before
    roof installation
  • Video available online

21
Installation
  • Fabral specifications clearly outline the scope
    of work and installation responsibilities
  • Fabral manufactures and delivers the entire
    system to specification
  • The system is installed in two steps
  • The BIPV roofing panels by the trained roofing
    contractor
  • The electrical system by the electrical
    subcontractor

22
Warranty
  • The Fabral Solar SSR system comes with a
    Fabral/EnergyPeak 25-year manufacturers
    warranty
  • 25 Years

23
ROI
  • The perfect start
  • Can be processed via paper or online at
    www.fabral.com/ROI.php
  • Calculations are available for all power size
    options
  • All current federal rebates, state and local
    incentives, utility provider incentives,
    renewable energy credits and depreciation are
    shown
  • ROI well under 10 years is common
  • About 7 days for results

24
Tax Credit Advantages
30 Solar IRS tax credit is available on PV
systems - Extended through 2016 - Previous cap
on residential PV systems has been REMOVED,
significantly increasing the tax incentives for
residential applications - Many state and local
utility rebates exist PLUS dont forget -
Homeowner Energy Credit of 30 for projects using
metal roofing meeting ENERGY STAR (cool colors)
requirements - Maximum credit is 1500 - Does
not include installation costs - Must be
installed during 2009 or 2010
25
Drawings Specifications
  • Fabral will supply all required AutoCad drawings,
    electrical schematics and Masterspec
    specifications for both the electrical and
    roofing sections
  • Electrical schematics and specifications should
    be given to the electrical engineer for review

26
A better understanding of Solar SSR
Solar Building Integrated Photovoltaic (BIPV)
for Standing Seam AND Exposed Fastener Roof
Systems
Write a Comment
User Comments (0)
About PowerShow.com