Title: DA?NE Upgrade DA Optimization
1DA?NE Upgrade DA Optimization
- December 12, 2006
- E.Levichev, P.Piminov, P.Raimondi, M.Zobov
2Optimization algorithm
- chromaticity vector
- sextupole pair
- N small steps for chromaticity correction by
every sextupole pair along the chromaticity
vector - The pair providing the largest DA at the step is
fixed - The procedure is repeated until the chromaticity
is corrected - 6D aperture optimization is available
- Harmonic sextupole (zero dispersion) is included
by the gradient search.
3Starting point DA?NE Siddharta
Lattice from Manuela Boscolo
Betatron tunes Qx/Qy 5.103/5.179
Compaction factor a 0.0193
Damping times (ms) tx/ ty/ ts 39.8/34.5/16.1
Horiz emittance (nm-rad) ?x 390
Energy spread ?E/E 3.9?10-4
Natural chromaticity ?x/ ?y -3.2/-25.9)
IP1 betas (m) ßx/ ßy 0.2/0.006
Beam size at IP1 (?m) ?x/?y 284/3.4
) With sextupole term in the wiggler end
pole Corrected chromaticity
4Optics of DA?NE Siddharta
5Optimization scenario
- Original DA
- Optimization of the original DA
- DA tune scan and tune point choosing together
with the luminosity scan - Checking of other nonlinear elements octupole
magnets, wiggler end poles, etc.
6DA at the original tune point
Original sextupoles Sextupoles optimized by the
best pair method
7Luminosity tune scan
8DA tune scan
9Optimized tune and DA
Original 5.103, 5.179/non optimized Point from
region 1 5.105, 5.160/optimized Point from
region 2 5.131, 5.116/optimized
10Summary table
Tune Point N?x N?y Comments
5.103, 5.179 13/-16 180 Original
5.103, 5.179 16/-23 250 Original, optimized
5.105, 5.160 20/-26 300
5.131, 5.116 20/-23 270 Coupling resonance
11Off energy DA
12Other nonlinearities adjustment
- Influence of octupoles to the optimized sextupole
set is negligible - Wiggler end pole sextupole including in the
optimization process gives practically the same
value (10-15 less) as it is now. It seems there
is no necessity to modify it.
13Summary
- Best sextupole pair optimization provides
increasing of the DA?NE Upgrade DA - Tune point with high luminosity and large DA is
chosen - No necessity to modify mechanically the wiggler
pole