Title: Material Property R
1Material Property RD Review of remaining tests
- Single conductor torsion tests
- Transverse compression at LN2
- 4 turn racetrack fatigue tests
-
- Multi-turn beam bending and torsion tests,
including fatigue - Mod coil casting material fatigue property tests-
2 welded, 9 non-welded from EIO - - 2-D glass/epoxy tests (for TF,PF coils only) and
need for 3-D - Compile material property database
Kozub, Chrzanowski Kozub, Chrzanowski Nelson,
Cole Heitzenroeder Kalish HM Fan
2Material Property RD Review of remaining tests
- Single conductor torsion tests 40 hours 2 wks
cal. time - Transverse compression at LN2 8 hours couple
days - Dogbone test - 8 hours _at_RT, can we do LN2?
not easy - 4 turn racetrack fatigue tests 200 hours left
- - pull long coil to failure, find out max load,
resistance vs strain at room temperature week
or two, done by Oct 15 - Increase cyclic load in 1st short coil to 20000
lbs at LN2 and run to appropriate number for 33
load increase, start by Oct 19 - Increase cyclic load in short coil to 25000 lbs
at LN2 and run appropriate number of cycles for
67 load increase - Increase load to 30000 lbs and run to failure,
end by Nov 10 - Review plan, then run 2nd coil (e.g. max load not
to exceed failure strain at RT, or some other
test, must end by Nov 24 or start after Dec 15
3Full scale beam bending and torsion test
- 3-point bend / torsion test in 4-column MTS load
frame - RT or LN2 temp
- 5 extensiometers
- Left, right ends,
- Left, right midpts
- Center
- Tests for
- Load / deflection
- Fatigue
- 3 specimens
- Original 18 turn beam
- 40 turn beam
- 40 turn beam with crossovers
4Full scale beam bending and torsion test - Status
- Complete
- Beams on site and prepped for test (cut to 42 in
long) - All fixtures completed (except insulation)
- 5 extensiometers on hand
- FEA of original beam completed for bending only
- Original beam loaded for testing
- To Do
- Write test / safety procedure for LN2 operation
(part of 1403-42F, 24k total in plan) - Procure approved insulation system (part of
1403-42F) - Perform deflection and fatigue tests 2 wks from
start (part of1403-42F) - Perform FEA analysis of new beams, incl leads (in
plan 22k-1403-42G)
5Beam FEA model 18 turn sample 1
- ½ of beam (one side 9 turns) modeled
- E-cable/epoxy 9.5 e6 psi
- E-epoxy/glass insulation 1.5 e6 psi
- Supported at ends and loaded in center
- Loads and supports through small pads
6Vertical Deflection, 2000 lb load 0.05 inches
7Von Mises stress, 2000 lb load peaks at load point
8XX (lateral) Stress, 2000 lb load, 0 except load
pt
9YY(vertical) Stress, 2000 lb load, 0 except
load pt.
10ZZ (axial) Stress, 2000 lb load, 7.5 ksi tension
11YZ (Shear) stress, 2000 lb load
12Hand calculation E effective for .05 in.
defl6.3 Msi