1
  • CASE STUDY
  • NAVAL WEAPONS CENTER ROCKET FUEL LOADER

2
  • REQUIREMENT
  • LOAD ROCKET FUEL MODULES REMOTELY IN CLASS I
    DIV II ENVIRONMENT, ALL ELEMENTS REQUIRED TO BE
    INTRINSICALLY SAFE/EXPLOSION PROOF.

3
  • PRESSURE NEMA 4X ENCLOSURE AND SAFETY
    BARRIER.  REMOTE KEYPAD OUTSIDE ROOM OPERATES
    SYSTEM. CONTAINERS ARE INDEXED INTO POSITION,
    FILLED, INDEXED OUT.
  • ACTIONPAC DESIGNED
  • SYSTEM TO RIGHT ANGLE INDEX SS LOADING
    CONTAINERS FOR 1000g FILLS OF RED PHOSPHORUS WITH
    /- 200mg PRECISION.  ALL FEEDERS, CONTROLS,
    INDEXING EXPLOSION PROOF/INTRINSICALLY SAFE WITH
    POSITIVE

4
  • ALSO EQUIPPED WITH ZERO VERIFY FEATURE,
    ITEM/FILL RECORDER WITH STRIP PRINTER AND
    RECORDING SOFTWARE.  ZERO VERIFY, SIMPLY PUT,
    MEANS THAT DROPPED WEIGHTS ARE VERIFIED
    ABSOLUTELY.  IF THE EMPTY WEIGH BUCKET CAN BE
    SHOWN TO BE AT
  •  

5
  • ZERO, THEN THE PREVIOUS WEIGHT BY EXTENSION
    MUST CONFORM TO THE TARGET.  VALIDATION TEST
    RESULTS ZERO ERRORS IN 1000 CYCLES.