1Automation and Asset Tracking in Surgical
Pathology Barcoding, Tracking, Chain of Custody
in a Small System
Edward P. Fody, MD, Chief of Pathology, Holland
Hospital Holland, Michigan
Foundation.cap.org
2(No Transcript)
3Advanced Materials Processing (AMP) throughout
the pathology lab
- Accessioning
- Gross Examination
- Histology
- Microscopic Examination
4Accessioning
- Specimen labels and cassettes are printed with
barcodes
5Specimen label on container
6Accessioning
- Specimen labels and cassettes are printed with
barcodes - Label is placed on specimen container(s) and
requisition
7Accessioning
- Specimen labels and cassettes are printed with
barcodes - Label is placed on specimen container(s) and
requisition - Cassettes go with container in their own bin
compartment
8Specimen bins, individual compartments for each
case
9Gross examination
- Bar code on container is scanned and case opens
up in Powerpath
10Gross examination
- Bar code on container is scanned and case opens
up in Powerpath - Using Voicebrook dictation system, case is
dictated and sections are submitted within
barcoded cassettes
11Gross examination
- Bar code on container is scanned and case opens
up in Powerpath - Using Voicebrook dictation system, case is
dictated and sections are submitted within
barcoded cassettes - If additional orders are produced (e.g. special
stains, frozen sections), the barcode will now
have this information attached
12Histology
- Embedding
- Computer at embedding station for embedder to
easily mark each case as completed
13Histology
- Embedding
- Microtomy
- Cassette is scanned at the bench and slide labels
automatically print - Each station has its own computer, barcode
scanner and label printer - AMP system automatically marks each cassette as
completed and each slide as in process
14Histology
- Embedding
- Microtomy
- Slide check out
- Each slide is scanned at our check out station
and the AMP system marks it as completed in
Powerpath
15Microscopic examination
- The pathologist scans a slide and the correct
case opens up in Powerpath - Case is dictated using Voicebrook dictation
system - Case is either signed out or additional tests can
be ordered - If additional tests are ordered, a new order
appears in histology worklist and the histotech
can rescan the block all new labels will now
print
16Pathologist orders additional stains
- Ordering Special Stains/Immunohistochemical
stains - Ventana stainer is interfaced with Powerpath
- Case is highlighted in Ventana and labels are
printed - Histotech sees order in Powerpath worklist, scans
block for Powerpath labels (which are placed over
Ventana label after staining)
17Advantages to barcoding and AMP
- Barcoded specimen containers ensure correct case
is being dictated - No need to handwrite slides/cassettes, eliminates
human error of mislabeling and smudging - Each slide label individually prints and each
case is handled separately, thus no mislabeling
amongst cases - Cassettes and slides can be followed through
histology with AMP simply look into a case to
see what step they are at and where to find a
case if needed
18Internet Module
- Clinicians and their staff can easily view
patients results via our internet module - Website is customized
- http//pathology.hollandhospital.org
19Internet Module
- Clinicians and/or their staff can easily view
patients results via our internet module - With a protected user ID and password, this site
can be accessed anywhere internet access is
available.
20Internet Module Summary
- The internet module allows a physician to quickly
and easily access patients pathology results
from any computer and to view the photographs in
color and enlarged
21Additional features of AMP since we went live
with our system
- Grossing station
- Embedding station
- Diagnostician station
- Specimen Discard Station
- Slide/Block Storage Station
22Grossing Station
- Scan cassettes to verify info matches with
container - Order/print additional cassettes remove unused
extras - Add number of pieces and special embedding
instructions to a cassette
23Embedding Station
- Track cassettes arriving at embedding
- Verify number of pieces in cassettes
- View embedding instructions
24Diagnostician Station
- Scan a slide to receive all slides for case
- Auto load case in Powerpath
25Specimen Discard Station
- Scan a container to check if specimen can be
discarded
26Storage
- File blocks and slides
- Check for availability from file storage
- Check out/Check in materials
27Barcodes and Patient Safety
- Right Patient
- Right Test
- Right Time
28Whats Next For Barcoding?
- Wristbands
- Lab Tests
- Blood Bank
- Pharmacy