LCLS Ultrafast Science Instruments (LUSI) - PowerPoint PPT Presentation

About This Presentation
Title:

LCLS Ultrafast Science Instruments (LUSI)

Description:

... details in break outs Hazards Analysis cont d The purpose of this HAR is to identify hazards associated with the design ... Thermal/Cryogenic ... – PowerPoint PPT presentation

Number of Views:60
Avg rating:3.0/5.0
Slides: 16
Provided by: AMUE5
Category:

less

Transcript and Presenter's Notes

Title: LCLS Ultrafast Science Instruments (LUSI)


1
LCLS Ultrafast Science Instruments (LUSI)
Environment Safety and Health
M. Scharfenstein ESH Coordinator August 19-21,
2008
2
Integrated Safety and Environmental Management
  • SLAC Integrated Safety and Environmental
    Management
  • SLAC ESH Manual
  • LCLS Directorate Plan
  • LCLS ESH management practices
  • LCLS Requirement, Specification and Interface
    Documents
  • Physics Requirements Documents , Engineering
    Specification Documents , Interface Control
    Documents , etc
  • LCLS Work Authorization
  • SOC Reviews
  • ESH Reviews
  • PMT sign-off
  • The HAR reflects that LUSI is being developed
    following
  • DOE O 413.3A / Program and Project Management
  • DOE O 420.2A / Accelerator Safety
  • DOE O 450.1 / Safety Management System

3
Hazards Analysis
  • Living document subject to an annual review,
    following LCLS QA protocols
  • Hazards Analysis Report
  • Reviewed and Approved by the DOE Stanford Site
    Office
  • DOE O 413.3A / Program and Project Management
  • DOE O 420.2A / Accelerator Safety
  • DOE O 450.1 / Safety Management System
  • Peer Review
  • Hazards Analysis Report
  • R. Hislop
  • SME, Author Reviewer
  • APS
  • F. ONeil
  • SME, Author of GLAST HAR

4
Hazards Analysis contd
  • The purpose of this HAR is to identify hazards
    associated with the design and operation of the
    LUSI project assess risk and establish controls
  • Hazards capable of causing injury to personnel,
    harm to the environment, or damage to critical
    hardware have been considered in the analysis
  • This HAR documents the safety analysis of the
    LUSI instrument design/build/install test
  • A separate Operating and Support Hazard Analysis
    (OSHA) will be developed for LCLS experiments.
    The OSHA will evaluate activities for hazards
    introduced into the system by operational and
    support procedures

5
Hazards Analysis contd
  • The Environmental Assessment developed for the
    LCLS resulted in a Finding of No Significant
    Impact encompassed the physical space occupied by
    LUSI and its operations.
  • LUSI instruments are being designed so that they
    will not pose hazards to people or the
    environment.
  • The most significant potential hazard associated
    with LUSI instruments is that associated with
    ionizing radiation.
  • The LUSI instruments are designed to 10CFR 835
  • defines radiation protection regulations for the
    protection of individuals from ionizing radiation
  • LUSI will design, build, install and test
    instruments within parameters of LCLS SAD
  • The instruments will comply with the approved
    Accelerator Safety Envelope (ASE)

6
Overview of Hazards
  • The results of the Hazards Analysis Report were
    consistent with those of the LCLS analysis that
    resulted in a low hazard facility determination
    following the criteria defined in DOE-O 420.2B,
    Safety of Accelerator Facilities, based on the
    following
  • LCLS requirements for SLAC Linac operations are
    well within existing safety and operating
    envelopes of the facility.
  • The average power of the LCLS x-ray beam, the
    energy and power of the electron beam, and hence
    the radiation hazard they pose are all well
    within the range of applicability for SLAC
    shielding and safety systems
  • The risk (probability consequences) of all
    hazards will be similar in nature and magnitude
    to those already found in the present accelerator
    storage ring experimental programs
  • Existing and mature programs (citizen safety
    committees, ESH division, Work Authorization)
    will be engaged to ensure that all aspects of the
    design, installation, and testing phases of LUSI
    will be properly managed

7
LUSI Configuration
  • Workplace Hazards Analysis
  • Radiation
  • Fire Protection
  • Electrical
  • Seismic
  • Chemical
  • Thermal/Cryogenic
  • Mechanical
  • Environmental Insults
  • Air Emissions
  • Waste Material Disposal
  • Magnetic
  • Oxygen Deficiency
  • Vacuum / Pressure
  • Laser
  • Hardware Design Hazards
  • Pinch points
  • Sharp corners

X-RAY PUMP/PROBE
8
Hazard Assessment Process
  • The hazard assessment process is a principal
    factor in the understanding and management of
    technical risk. System Safety is an integral
    part of the overall program risk management
    decision process
  • Hazard severity is an assessment of the worst
    potential consequence, defined by degree of
    injury or property damage, which could occur
  • Probability is the likelihood that an identified
    hazard will result in a mishap, based on an
    assessment of such factors as location, exposure
    in terms of cycles or hours of operation, and
    affected population.
  • These levels are derived from MIL-STD-882D,
    Standard Practices for System Safety.
  • Defense Standards are also used by other
    non-Defense government organizations, technical
    organizations, and industry

9
System Safety
  • System Safety is an integral part of the overall
    program risk management decision process
  • Design to Eliminate Hazards
  • Design to Control Hazards
  • Provide Safety Devices
  • Provide Warning Devices
  • Provide Procedures or Training
  • Hazard Acceptance or Terminate System

10
Occupational Safety Requirements
  • The LUSI equipment shall be designed and
    constructed in such a manner to protect the
    safety of workers, the public and the environment
    following 29CFR1910. The safety philosophy and
    practice to be followed on the LUSI project will
    include the following elements
  • DOE P 450.4 Safety Management System Policy
  • Adherence to SLAC Work Smart Standards
  • 10CFR835 Occupational Radiation Protection /
    ALARA
  • Controlling hazards by eliminating them whenever
    possible
  • Implementing safety programs to ensure worker
    safety during construction and testing
  • Performing independent design reviews

11
Installation Phase Hazards
  • Radiation there is no source of radiation
    during the fabrication and installation phases
    of the project
  • Fire Protection - LUSI is protected by a
    conventional fire sprinkler system and a Very
    Early Smoke Detection Apparatus (VESDA) system.
  • Electrical hazards will be controlled by
    adhering to NFPA 70E standards
  • Thermal/Cryogenic Handling of cryogens shall be
    compliant with SLAC ESH Manual Chapter 36,
    Cryogenic Oxygen Deficiency Hazard Safety
  • Oxygen Deficiency hazard potential is minimal
    due the small quantities of gases in liquid state
    that will be used within the facility
  • The requirement for air monitoring will be
    included in the evaluation of the hutches.
  • Vacuum / Pressure - LUSI consists of numerous
    vacuum components and the vacuum chambers will
    have burst disk that are compliant with 10CFR851.
  • Pressure relief valves are integral to the vacuum
    system to prevent them from being
    over-pressurized while venting.  
  • Others Chemical, Environmental Insults,
    Magnetic, Mechanical, Seismic
  • Identified and addressed

12
Operations Safety
  • Workplace Hazards Analysis
  • Radiation
  • Fire Protection
  • Electrical
  • Seismic
  • Chemical
  • Thermal/Cryogenic
  • Mechanical
  • Environmental Compliance
  • Control of Effluents
  • Oxygen Deficiency
  • Vacuum / Pressure
  • Robot Arm
  • Laser
  • Occupational Safety
  • Radiation Exposure Control
  • Personnel training
  • Shielding configuration control
  • Monitoring
  • Safety Interlocks
  • Beam Loss Control
  • Radiation monitors
  • TLDs for personnel and areas
  • Waste Minimization
  • Experiment review
  • Quantities minimized
  • Less hazardous substitutions
  • Disposal process

13
Hazard Consequence Rating
14
Conclusion
  • Integrated Safety and Environmental Management
  • Following SLAC ISEMS Plan
  • LCLS Directorate Plan
  • Following SLAC ESH Manual
  • Following LCLS ESH management practices
  • Work Authorization
  • Hazard Analysis Report
  • Approved by DOE SS0
  • ESH requirements met for CD-2

15
ESH
  • Thank you
Write a Comment
User Comments (0)
About PowerShow.com