ATLAS Muon Detector Description - PowerPoint PPT Presentation

About This Presentation
Title:

ATLAS Muon Detector Description

Description:

alignment Tool event display geometry DB Lo spettrometro a muoni di ATLAS Nuova versione della Geometria Il confronto con i dati (cosmici) forza a migliorare il ... – PowerPoint PPT presentation

Number of Views:33
Avg rating:3.0/5.0
Slides: 8
Provided by: fisicaUni
Category:

less

Transcript and Presenter's Notes

Title: ATLAS Muon Detector Description


1
ATLAS Muon Detector Description sviluppi
nellultimo anno
  • MuonGeoModel sw che descrive la geometria dello
    spettrometro a muoni di ATLAS nel framework
    offline generale dellesperimento
  • implementato a Lecce a partire dal 2003
    condiviso da simulazione e ricostruzione
  • S.Spagnolo and L.Chevalier Muon Detector
    Description task leaders da Sett. 2007

condition DB
Il tool di allineamento fornisce run-time
costanti che consentono di descrivere in
MuonGeoModel spostamenti, rotazioni e
deformazioni delle camere GOAL 30-40mm
risoluzione dellallineamento globale
alignment Tool
event display
geometry DB
2
Lo spettrometro a muoni di ATLAS
display del barrel
1700 alignable detector stations, 1200 MDT
chambers consisting of two arrays of staggered
aluminium drift tubes, 1-6 m long, 3 cm diameter,
400 mm thin Al wall, 1000 RPC units 1500 TGC
units 32 CSC chambers complex inert materials
(barrel toroid coils, ec toroids, feet, support
structures, shielding materials, calorimeter
saddle)
3
Nuova versione della Geometria
  • Il confronto con i dati (cosmici) forza a
    migliorare il realismo della descrizione della
    geometria
  • ATLAS-GEO-00-00-00
  • Moving from Layout R in tech. drawings to the MS
    layout as installed (amdb version R03)
  • Active Geometry
  • MDT HV-RO side checked and fixed for a few
    chambers
  • station positions fixed for a few stations
  • RPC layout in Small Sectors RPC positioning in
    the stations with single RPC units RPC chambers
    with cutouts RPC special chambers heavily
    revisited
  • CSC position fixed (layer 2 installed not layer
    1)
  • Dead Matter
  • In the XML description fixes to MDT Big Wheel,
    Calorimeter Saddle, TGC support pos. of ID Patch
    Panels PP2 Muon Barrel sect. 13) Access
    Platforms, Feet Struts, pos., BOL Support, Tie
    road, ECT cryostat fix
  • Status of R03
  • ready for production / currently in validation

4
RPC layout in R03
  • As shown also from hit residuals studies
    with cosmic ray data, the RPC layout in the small
    sectors does not correspond to the nominal layout

see B. Liberti et al http//indico.cern.ch/getFil
e.py/access?contribId0resId0materialIdslides
confId32282
ATLAS-CSC-01-00-00
ATLAS-GEO-00-00-00
Layout as installed
Nominal Layout
5
RPC layout in R03
BOG as an example of chamber with single RPC
unit in some cases inverted position of gas
gaps and thick support panel
  • changed w.r.t. R01 in
  • position in the station
  • of eta strips
  • cutouts

s3 RPC chambers
s2 RPC chambers
BMS5 BMS2A/CX
BMS4 BMS3A/CX
BMS6 BMS4A/CX
6
Riorganizzazione del decoding dei dati
Il caso RPC struttura dei dati online molto
diversa dalla struttura dei dati offline
  • h.w. duplicated hits due to cabling overlap
  • s.w. duplicated hits due to wired-or and
    logical-or
  • 3 types of trigger hits in the readout

Al Filtro (ultimo passo del trigger di alto
livello), lalgoritmo di muon-identification deve
accedere solo ad una frazione dei dati (nella
regione di interesse) per ridurre il tempo
richiesto per la decodifica dei dati e
minimizzare la combinatoria nel track finding
7
La proposta RPC
HLT applications or offline selective mode
LIST OF data collection IDENTIFIERS
Offline event dump mode
overall data request empty list
RDO to PRD Tool new
  • allows to share logic (and implementation)
    between HLT and offline

LIST OF PADS new
  • avanzata da Lecce
  • adottata da tutti i sottorivelatori del MS
  • in funzione per la prima release destinata
  • alla presa dati

TRANSIENT EVENT STORE
Bytestream RDO standard Converter
RDO
Data clean-up existing logic
PRD
Write a Comment
User Comments (0)
About PowerShow.com