Title: Total HVAC Control from anywhere
1Total HVAC Control from anywhere Easy control
that can save a fortune
2General
Maxinet is a web based, Mini BMS application for
controlling Central HVAC System. It enables a
secured monitoring control of the HVAC system
at site by multi-users from anywhere in the
world, via access to the intranet/internet.
Maxinet is suitable for small to medium size
buildings and can save 20-30 of HVAC
electricity costs.
3General
- Energy saving solution
- Reduces HVAC electricity costs by 20-30
- Simple, generic and affordable Software
- Suitable for small to medium applications
- Allows gradual expansion of your network
additional thermostats can be
added later - Compatible with standard 220Vac/24Vac Thermostats
with built in communication - Routers include display buttons to control
network - Controls also other energy consuming
devices/systems by I/O Card (CTU1601)
4Features
- Works with all HVAC applications F/C, DX, VAV,
Multi Zone
- End-users have limited control by
- Programming set point limits
- Locking end units
- Different weekly programs for each unit or zones
- Cost usage reports and graphs
- General purpose I/O card with 8 digital outputs,
8 digital inputs and 3 Temperature readings, to
control other energy consuming systems thru the
software
- Easy to operate and manage. Last operation
rules end user or system
- Access Control from a remote location
5Basic HVAC control structure Layout 1 / 2 / 3
Floor X
Floor 2
Floor 2
Up to 60 units
MCU
CTUPanel (ETN-X500)
CTUPanel (FMH-X500)
Floor 1
Floor 1
Up to 60 units
MCU
PS1601 I/O card
ETNC
FMHC
Adaptor RS232/ RS485
WWW
Firewall
6Control Structure
Accessibility Permissions
Floor 1
MCU
Floor 2
MCU
End User - View and change properties of one unit
Manager - View and change properties of all units
Administrator - View and change properties of all
units. Assign
privileges to end users.
7Controlling the units
remote computer
WWW
Wall Mount MCU Master Unit Control
Local computer
Panel / Remote control
8Installation Options
Option 1
Option 2
Option 3
Local server/ computer in customers Ethernet
Easy CD installation
Remote installation at customers site via
the Internet by Meitav-tecs technician
Remote hosting server - (option)
Requires permission for internet access
9MaxiNet Software Log in Screen
http//www.maxineto.com/Demo/
Guest
Guest
10MaxiNet Software Main Screen
11Friendly Software
Graphic Display of Units
Easy change of settings in thermostats
One Thermostat, One Icon
Unit number or name
Set point
Room temp.
Mode
Fan speed
Enlarge unit
Select unit
12Enlarge Unit
Seen by Maintenance Controller or Administrator
ONLY
Tset 22C
Tset 21C
Tset 23C
Amb 28C
13Software Weekly Program
14Software Temp Per Time Graph
15Software Cost Per Time Graph
16Software Exceptions Per Unit Graph
17Software Energy Control
18Components for Software
- CD install
- Adaptor RS232-RS485
- Cable for Com connection
- Transformer for Adaptor
- All components are supplied with the software
Easy to install and connect Plug Play
2 wires to thermostats
19- Maxinet is an
- advanced,
- user friendly,
- web based program
- for cost effective easy
- HVAC control monitoring
20MCU - Master Control Unit
- Optional unit for networks, up to 60 units
- Perfect solution for FLOOR applications
- to view locally the units in the sub network
- Easy to view and make changes
- - Mode
- - Fan speeds
- - Set temperature
- - Set temperature limit
- - On/Off
- Broadcast for all sub network
- Emergency weekly program is activated
- automatically when software is not working
- The most simple router to use in the market
21Network Thermostats Controllers
Different choices for Thermostats
Controller PS 1800-FC-Super (Commercial)
Controller PS 1800-AC-Super (Commercial)
Wall-mount
Flush-mount
Controller CTU X500-FC-Super (Commercial)
22Wall Flush Mount Panels
Wall-mount - ETN
Flush-mount - FMH
or
23Wall-Mount Thermostat 24VAC
- Wall-mount, 24VAC thermostat
- Communication Built-in
- Dip switch for physical address
- Set point limits password protected
- Easy to install and use
- Pre-programmed at factory
- (no field programming required)
- Option for External or Average sensors
24Flush-Mount Thermostat 220VAC
- Flush-mount - 220VAC thermostat
- Communication built-in
- Dip switch for physical address
- Set point limits password
- protected
- Easy to install and use
- Pre-programmed at factory
- (no field programming required)
- External sensor option
- Fits into Standard Gewiss Box
- (GW00001481VR)
25Controller PS1800-AC-Super
- A robust, energy saving controller with Maxinet
communication protocol - Offers various A/C applications field
selectable - Heat/Cool or Heat Pump, 3 speeds 1 speed
- Wall or Flush mount thermostats - complete
optional - Enables viewing temperature sensors in Software
Indoor/Outdoor coil - Includes cost efficient capabilities, such as
occupancy sensor cooling stages - Pre-programmed at factory (no field programming
required)
220VAC input
220VAC outputs
RS-485 Communication
26Controller PS1800-Fan Coil-Super
- A robust, energy saving controller with Maxinet
communication protocol - Offers various configurations for Fan Coil
applications field selectable - 4-pipe, 2-pipe No Valves and change over
sensor - Includes cost efficient capabilities, such as
occupancy sensor window contact - View temperature sensors in Software Indoor
coil and change-over-sensor - Wall or Flush mount thermostats - complete
optional - Pre-programmed at factory (no field programming
required)
220VAC input
220VAC Outputs
RS-485 Communication
27Thermostats for Controllers
FMH-X500
ETN-X500
Temperature Sensors
TS01
RS02
RS01
Temp. Sensor
Average Sensor
Decorative Sensor
28I/O Card CTU1601
Controls through software other devices, such
as Extractors, Fan, Fresh Air Dampers, Chiller,
Lights, Air compressors, etc.
- 8 Outputs 220 Volts 0.5A Controlled through
the software - 8 Inputs Dry Contact Voltage Free Viewed
in the software - 3 Temperature readings Viewed in the software
29Input/Output card - Control
30Schematic Installation Layout 1
- Network with MCU
- Up to 60 units
Up to 60 units
MCU
PS1601 I/O card
ETNC
FMHC
31Schematic Installation Layout 2
- Network with Software
- Up to 60 units
32Schematic Installation Layout 3
- Network with MCU and Software
- Controlling the network from software or from