Periodontal Instrumentation (II) - PowerPoint PPT Presentation

1 / 69
About This Presentation
Title:

Periodontal Instrumentation (II)

Description:

Periodontal Instrumentation (II) General principles of instrumentation * Accessibility (position of operator & patient) * Visibility, illumination and retraction ... – PowerPoint PPT presentation

Number of Views:987
Avg rating:3.0/5.0
Slides: 70
Provided by: kmuEduTw9
Category:

less

Transcript and Presenter's Notes

Title: Periodontal Instrumentation (II)


1
  • Periodontal Instrumentation (II)

2
  • General principles of instrumentation
  • Accessibility (position of operator patient)
  • Visibility, illumination and retraction
  • Condition of instruments
  • Maintaining a clean field
  • Instrument stability
  • Instrument activation

3
  • Position
  • Operator--- feet are flat on the floor and
    thighs parallel to floor, keeping back straight
    and back erect

4
  • Neutral seated position Neutral neck position

5
  • Neutral back position--- forward slightly
  • from waist or hip

6
  • Supine Patient position
  • Patients heels should be slightly higher than
    tip of his nose, good blood flow to the head
  • Mouth is close to resting elbow of operator

7
  • Patient
  • Instrumentation of maxi. arch, raise the chin
  • slightly to provide optimal visibility and
  • accessibility
  • Instrumentation of mand. arch, lower the
  • chin until mandible is parallel to floor

8
  • Position of operator patient

9
  • Optimum Visibility
  • The following methods are effective for
    retraction
  • 1) Use of mirror to deflect the cheek while
    the finger
  • of non-operating hands retract the lip
    and protect
  • the angle of mouth from
  • irritation by the mirror
  • handle

10
  • 2) Use the mirror alone to retract lip and cheek
  • 3) Use the mirror to retract tongue
  • 4) Use the fingers of non-operating hand to
    retract
  • the lip
  • 5) Combination of the preceding

11
  • Illumination
  • Direct vision
  • and
  • illumination

indirect vision and illumination
12
  • Illumination (dental light position)
  • Mand. Tx. areas Max. Tx areas

13
  • General principles of instrumentation
  • Accessibility (position of operator patient)
  • Visibility, illumination and retraction
  • Condition of instruments
  • Maintaining a clean field
  • Instrument stability
  • Instrument activation

14
  • Condition of instruments (sharpness)
  • Sharp instruments enhance tactile sensation
    and allow the clinician to work more precisely
    and
  • efficiently
  • Maintaining a clean field
  • Saliva and gingival bleeding interfere
    visibility and impede (??)control

15
  • General principles of instrumentation
  • Accessibility (position of operator patient)
  • Visibility, illumination and retraction
  • Condition of instruments
  • Maintaining a clean field
  • Instrument stability
  • Instrument activation

16
  • Instrument stability
  • Two factors of major importance in providing
  • stability are the instrument grasp and finger
    rest
  • a. Instrument grasp
  • A proper grasp is essential for precise
    control
  • of movements made during periodontal
  • instrumentation

17
  • a. Instrument grasp
  • (1) Modified pen grasp
  • (2) Palm and thumb grasp

18
  • Modified pen grasp
  • The middle finger is positioned so that the side
    the
  • pad next to the fingernail is resting on the
  • instrument shank. The index finger is bent at
    second
  • joint from the finger tip and is positioned well
    above
  • the middle finger on the same
  • side of the handle

19
  • Modified pen grasp

20
  • b. Finger rest
  • Serves to stabilize the hand and instrument
    by
  • providing a firm fulcrum as movement are made
  • to activate the instrument. Generally be
    classified
  • as intraoral finger or extraoral fulcrum
  • Intraoral finger rests
  • (1) Conventional
  • (2) Cross arch
  • (3) Opposite arch
  • (4) Finger on finger

21
  • Intraoral finger rests
  • (1) Conventional
  • (2) Cross arch
  • (3) Opposite arch
  • (4) Finger on finger

22
  • b. Finger rest
  • May be generally be classified as intraoral
    finger
  • or extraoral fulcrum
  • Extraoral fulcrum
  • (1) Palm up
  • (2) Palm down

23
  • General principles of instrumentation
  • Accessibility (position of operator patient)
  • Visibility, illumination and retraction
  • Condition of instruments
  • Maintaining a clean field
  • Instrument stability
  • Instrument activation

24
  • Instrument activation
  • 1. Adaptation
  • 2. Angulation ---Different angulation position
  • will cause different effective
  • 3. Lateral pressure
  • 4. Strokes

25
  • Adaptation the manner in which the working
  • end of a periodontal instrument is placed
    against
  • the surface of a tooth
  • ? To make the working end of instrument
  • conform to the contour of tooth surface
  • ? To avoid trauma to soft tissues and root
  • surface, to ensure maximum effectiveness
  • of instrumentation

26
  • Adaptation
  • The lower third of the working end must be
    kept
  • in constant contact with the tooth while it
    is moving over varying tooth contours

27
  • Adaptation
  • If only the toe or tip is in adapted, the soft
  • tissue can be distended or compressed by
  • the back of the working end, also causing
    trauma and discomfort, the toe can gouge
  • or groove the root surface

28
  • Angulation the angle between the face of a
    bladed instrument and tooth surface, also called
    tooth-blade relationship

29
  • The working-end is inserted at an angle
  • between 0- and 40-degrees.
  • The 0-to40o angle is referred
  • to as a closed angle

30
  • During S/RP, optimal angulation is between 45 to
    90 degrees.
  • The exact angulation depends on the amount and
    nature of calculus, the procedure being
    performed, and the condition of the tissue

31
  • Lateral pressure the pressure created when
  • force is applied against the surface of a
    tooth
  • with the cutting edge of a blade instrument
  • ?The exact amount of pressure applied
  • must be varied according to the nature
  • of the calculus and according to the
    stroke
  • is intended

32
  • Strokes exploratory, scaling root planing
  • Exploratory stroke--- the instrument is
    grasped
  • lightly and adapted with light pressure
    against the
  • tooth to achieve maximum tactile sensation

33
  • Scaling stroke is a short, powerful pull stroke
  • The scaling motion should be initiated
  • in the forearm and transmitted from
  • the wrist to the hand with a slight flexing
  • of the fingers

34
  • Wrist and forearm motion, finger flexing both are
  • necessary for complete instrumentation
  • The wrist and forearm motion, pivoting in an arc
    on the finger rest, produce a more powerful
    stroke --- preferred for scaling
  • Finger flexing --- for precise control over
    stroke length in areas such as line angles and
    when horizontal strokes are used on the lingual
    or facial aspects narrow-rooted teeth

35
  • Root planing stroke a moderate to light pull
  • stroke for final smoothing and planing of root
  • surface
  • A continuous series of long, overlapping shaving
    stroke is achieved

36
Periodontal therapy
Non-surgical
Surgical
Subgingival curettage, gingivectomy, Flap,
Osseous surgery, Guided tissue regeneration
Chemotherapy
Topical
Systemic
Mechanical debridement S/RP, OHI
37
  • Scaling instrumentation to remove all
  • supragingival uncalcified and
  • calcified accretions and all
  • gross subgingival accretion

38
  • Root planing instrumentation to remove
  • the microbial flora on the root surface or
  • lying free in the pocket, all fleck of
    calculus
  • and all contaminated cementum and dentin

39
  • Detection skills
  • Visual examination--- good light and a clean
    field.
  • Compressed air ?supragingival calculus
  • chalky white subgingival calculus dark shadow
  • Tactile sensation--- light exploratory strokes
    are activated vertically up and down on root
    surface

40
  • Detection skills
  • Tactile sensation--- the distance between
    apical edge of calculus and bottom of the pocket
    is 0.2 1.0 mm
  • Illumination

41
  • The rationale for root planing
  • Assumption that a smooth root surface will be
    less plaque retentive and therefore the danger
    of re-infection and recurrence of disease should
    be less
  • Reattachment of epithelial and connective tissue
    would be likely on a smooth root surface than on
    a rough one

42
  • Objectives of root planing
  • Securing biologically acceptable root surface
  • 2. Resolving inflammation
  • 3. Reducing probing depth
  • 4. Facilitating oral hygiene procedure
  • 5. Improving or maintaining attachment level
  • 6. Preparing tissue for surgical procedure

43
  • Principles for Gracey curettes usage
  • 1. Determine the correct cutting edge
  • 2. Make sure the lower shank is parallel to
  • root surface to be instrumented
  • 3. Using finger rest
  • 4. Concentrate on using lower third of
  • cutting edge for calculus remove
  • 5. Moderate lateral pressure

44
  • Determine cutting edge of Gracey curette
  • 1. Hold face of curette blade parallel with
  • floor and looking down on the face
  • 2. Notice the blade curve
  • 3. Larger, outer curve is
  • the correct cutting edge

45
  • The face of blade be close against the
  • tooth so it can only be partially seen

46
  • Make sure lower shank is parallel with
  • root surface

47
  • The functional shank extends from the first bend
    in the shank up to working-end
  • The lower shank is the bent section of the
  • shank nearest to the working-end

48
  • To avoid over-instrumentation, a delicate
  • transition from short, powerful scaling strokes
  • to longer, lighter root planing strokes must be
  • made as soon as calculus and initial roughness
  • have been eliminated

49
  • Hoe, files and ultrasonic instruments are
  • also used for subgingival scaling of heavy
  • calculus but not recommended for root planing
  • Curette is preferred for subgingival scaling and
    root planing

50
  • A common error in proximal instrumentation
  • is failing to reach mid-proximal region apical
  • to the contact point because this area is
  • relatively inaccessible and this technique
  • require more skill

51
  • The relationship between location of finger
  • rest and working area is important
  • 1. The finger rest or fulcrum must be position
  • to allow lower shank of instrument to be
  • parallel or nearly parallel with tooth
    surface
  • being treated

52
  • The relationship between location of
  • finger rest and working area is important

53
  • 2. Finger rest must be positioned enable the
  • operator to use wrist-arm motion to
  • activate strokes

54
  • Modes of calculus attachment reported by
  • Zander in 1953
  • Attachment by means of secondary cuticle
  • Attachment of calculus matrix to irregularities
  • of cementum surface corresponding
  • to previous insertion location of
  • Sharpeys fibers

55
  • 3. Penetration of microorganisms of calculus
  • into cementum
  • 4. Attachment in areas of cementum resorption
  • via mechanical locking into undercuts

56
  • Limitation of the effectiveness of scaling and
  • root planing
  • Anatomy of roots
  • Depth of pockets
  • Areas of mouth being treatment
  • Inadequate instruments for diagnosis
  • Inadequate instruments for treatment
  • Range of mouth opening
  • Dexterity of operator

57
  • Palato-gingival groove
  • Developmental abnormality
  • A funnel for the accumulation of plaque
  • and calculus in the depth of groove
  • Prevalence on incisors ranges from 1.9
  • to 4.4

58
  • Cervical enamel projections
  • Rapid progression of pocket formation
    (precluding
  • an organic connective tissue attachment)
  • Hemidesmosome attachment in CEJ ? less
  • resistant to breakdown by bacterial plaque ?
    rapid
  • progression of disease

59
(No Transcript)
60
(No Transcript)
61
(No Transcript)
62
(No Transcript)
63
(No Transcript)
64
(No Transcript)
65
(No Transcript)
66
  • Complications of scaling root planing
  • 1. Gingival bleeding
  • 2. Bacteremias
  • 3. Root sensitivity

67
  • Information to pt with root sensitivity
  • Sensitivity usually temporary
  • Through plaque control
  • Not discourage if desensitizing agent does not
    produce immediate effect
  • 4. Avoid foods that heighten sensitivity

68
  • Root desensitization agents
  • Silver nitrate, 10 strontium chloride, NaF,
  • formaldehyde, stannous fluoride, 5 KNO3
  • Ionotophoresis

69
  • ThankS for Your Attention
Write a Comment
User Comments (0)
About PowerShow.com