Posted CASfor DDR-II SDRAM
Posted CAS
  • Bill Gervasi
  • Technology Analyst
  • October, 2002

2
Traditional DDR-I SDRAM
CK
RAS
CAS
Data
tRCD
CAS Latency
  • RAS and CAS (read/write) issued independently
  • Controllers must insure the command bus is free
  • If collisions would occur, next command is
    delayed
  • Command streams and arbitration are complex

3
DDR-I Command Stream
Command Gap
CK
RAS
CAS
RAS
CAS
CAS
RAS
1
0
-1
0
1
2
Data
D
D
D
D
D
D
D
D
-1
-1
-1
-1
0
0
0
0
  • Shows string of commands to one DRAM extent
  • RAS2 delay of 1 clock results in a delay of 2
    clocks (to avoid landing on top of CAS1)
  • Data gap after D1 data caused by command gap
  • Assumed Page closed policy, tRCD3, CL2, BL4

4
DDR-II Posted CAS for Reads
CK
RAS
CAS
Data
CAS Latency
tRCD
Additive Latency
READ
Read Latency AL CL
  • Delay the internal execution of the CAS command
  • RAS/CAS commands can be issued back to back

5
DDR-II Posted CAS for Writes
CK
RAS
CAS
Data
CL - 1
tRCD
WRITE
Additive Latency
Write Latency RL - 1
  • Delay from write command to data tied to CAS
    Latency
  • Maintains write-to-read read-to-write timing
    relationship

6
DDR-II Command Stream
CK
CAS
RAS
CAS
RAS
CAS
RAS
0
1
0
1
2
2
Data
D
D
D
D
D
1
0
0
0
0
  • Shows string of commands to one DRAM extent
  • RAS2 delay of 1 clock results in a delay of 1
    clock (no collision to avoid, no additional
    delay)
  • Data gap of 1 command clock between RAS1/CAS1 and
    RAS2/CAS2 occurs later in time
  • Assumed Page closed policy, tRCD3, AL2, CL2,
    BL4

7
Open Versus Closed Page
RAS
CAS/AP
RAS
CAS/AP
RAS
CAS/AP
  • Closed page systems Auto Precharge
  • Requires RAS and tRCD to reopen same row
  • Open page systems do not issue Precharge if
    there is a good chance the same page will be
    accessed again
  • Avoids need for RAS and tRCD

RAS
CAS
CAS
CAS
CAS
CAS
PRE
8
Posted CAS with Open Page
Data would appear here without Posted CAS
CK
RAS
CAS
CAS
Data
CASLatency
AdditiveLatency
CASLatency
AdditiveLatency
Read Latency
Read Latency
  • Additive latency still included though not
    needed
  • In this case, Posted CAS reduces performance

9
Posted CAS Summary
  • Closed Page Policy
  • Allows RAS CAS to be issued back to back
  • No impacts to latency (from RAS)
  • No command collisions
  • Longer write recovery
  • Open Page Policy
  • Not likely to be used due to increased latency
    (from CAS)
  • Disable Posted CAS via programming register

10
DDR-II Read to Read, Posted CAS
Internal bank to internal bank
CK

RAS
CAS
RAS
CAS
0
1
0
1
Data
D
D
D
D
D
D
D
1
0
0
0
0
1
1
RL
Device to device, same databus
CK
RAS
CAS
RAS
CAS
0
1
0
1
Data
D
D
D
D
0
0
0
0
RL
Device Handoff Gap
11
DDR-II Read to Write, Posted CAS
Minimum interleave, bus limited, applies to all
situations
CK
RAS
CAS
RAS
CAS
0
1
0
1
Data
D
D
D
D
D
D
D
0
0
0
0
1
1
1
RL
WL

12
DDR-II Write to Read, Posted CAS
Internal bank to internal bank
CK
RAS
CAS
RAS
CAS
1
0
0
1
(CL 1 tWTR)
Data
D
D
D
D
0
0
0
0
WL
Device to device, same databus
CLK
RAS
CAS
RAS
CAS
0
1
0
1
Data
D
D
D
D
D
D
0
0
0
0
1
1
WL
W/R Turnaround Gap
13
DDR-II Write to Write, Posted CAS
Internal bank to internal bank or device to
device with MBT
CK
RAS
CAS
RAS
CAS
0
1
0
1
Data
D
D
D
D
D
D
D
1
0
0
0
0
1
1
WL
Device to device, same data bus with ODT
CK
CAS1
RAS1
RAS
CAS
0
0
Data
D
D
D
D
D
0
0
0
0
1
WL
ODT Shift Gap
MBT Motherboard Termination ODT On-Die
Termination
14
Conclusions
  • Posted CAS reduces command bus collisions
  • Results in higher data throughput
  • Optimized with WL RL - 1 for maximum data bus
    utilization
  • Can be disabled for open page systems
  • Simple concept, easy control, great benefit
Write a Comment
User Comments (0)
About PowerShow.com