Title: Project Director:
1(No Transcript)
2POLYMER RESEARCH LABORATORY
Project Director Prof. Dr. Tahir
Jamil Researcher (Chemical Engineer) Engr.
Shahzad Maqsood Khan
3POLYMER RESEARCH LABORATORY
EVALUATION OF SOLUBILITY PARAMETER OF LATICES
4SOLUBILITY PARAMETER
POLYMER RESEARCH LABORATORY
-
-
- It explains the solvency behavior of specific
solvent towards polymer in numerical values. - Solubility parameter is the indication of the
total Van der walls forces which is expressed in
the solubility values.
5COHESIVE ENERGY DENSITY
POLYMER RESEARCH LABORATORY
- Ecoh CED ?H - RT/Vm
- Where
- ?H Energy of vaporization
- R Gas constant
- T Temperature
- Vm Molar volume
- Ecoh CED Cohesive Energy Density
6COHESIVE ENERGY DENSITY
POLYMER RESEARCH LABORATORY
Cohesive Energy Density
Energy of vaporization
Indicate
Ecoh CED ?H - RT/Vm
Direct Reflection
Degree of Van der Waals forces
7COHESIVE ENERGY DENSITY
POLYMER RESEARCH LABORATORY
Van der Waals Forces (Inter Molecular Forces)
Vaporization
Solubility
8MISCIBILITY
POLYMER RESEARCH LABORATORY
If C1C2
Material 1 with CHE C1
9SOLUBILITY PARAMETER
POLYMER RESEARCH LABORATORY
- d
- In 1936 Joel H. Hildebrand proposed that the
square root of the cohesive energy density as a
numerical value indicating the solvency behavior
of a specific solvent naming the term as
solubility parameter denoted by d. - d (?Hv-RT)/Vm ½
- ?Ev/Vm 1/2
- CED 1/2
- v c
- Where
- ? Hv Heat of vaporization, R Gas constant, T
Temperature, vm Molar volume, CED Cohesive
Energy Density
10COHESIVE ENERGY DENSITYDIVISION
POLYMER RESEARCH LABORATORY
Ecoh Eh Ep Ed
11SOLUBILITY PARAMETER DIVISION
POLYMER RESEARCH LABORATORY
12SOLUBILITY PARAMETER DETERMINATION
POLYMER RESEARCH LABORATORY
- DETERMINATION OF EQUILIBRIUM SWELLING RATIO
- Q 1 (w2/w1) 1 ?2/?1
- Where
-
- Q Equilibrium swelling ratio of the polymer by
volume - W1 weight of the network before swelling
- W2 Weight of the network after swelling
- ?1 Density of the solvent
- ?2 Density of the Polymer
13SOLUBILITY PARAMETER DETERMINATION
DETERMINATION OF Qmax
Qmax
Qmax
Fig 3 Graph b/w Q and d to find Qmax for
butadiene binder.
14SOLUBILITY PARAMETER DETERMINATION
POLYMER RESEARCH LABORATORY
- Q/Qmax exp -a Q (dsolvent _ dpolymer)2)
- Equation can be rearranged as
-
- Q-1 ln (Qmax/Q)1/2 a1/2(dsolvent _
dpolymer) -
- According to a plot of Q-1 ln (Qmax/Q)1/2
versus the - solubility parameters of a series of solvents
will give a1/2 - and d polymer values from the slope and
intersection of the - horizontal axis of obtained line respectively.
15POLYMER RESEARCH LABORATORY
SOLUBILITY PARAMETER DETERMINATION
a x-axis value of maximum last point b
y-axis value of maximum last point below origin
(zero). c y-axis value of first point above
origin (zero) d x-axis value of first point
above origin (zero). z a (b c) / d y
z b a 1/2 (b c ) / d d y / a ½
16DETERMINATION OF EQUILIBRIUM VOLUME SWELLING
POLYMER RESEARCH LABORATORY
Veq (w2-w1/?1)/w1/?2
17DETERMINATION OF SOLVENT ABSORBENCY
POLYMER RESEARCH LABORATORY
Sab (w2-w1)/w1
18DETERMINATION OF EQUILIBRIUM SOLVENT CONTENTS
POLYMER RESEARCH LABORATORY
Seq (w2-w1)/w2 x 100
19EXPERIMENTAL WORK
POLYMER RESEARCH LABORATORY
- Study the effects of using different initiators
for latex synthesis. - Study the effects of using different emulsifier
for latex synthesis. - Study the effects of using different
concentration of the emulsifier for latex
synthesis. - Study the effect of different concentration of
co-monomer for latex synthesis. - Study the effect of solvent extraction on monomer
and the products. - Comparison of the industrial latex with the one
manufactured in the lab. - Study the change in the solid contents of the
product. - Determination of equilibrium swelling ratio.
- Determination of solubility parameter of the
binder, latex and the polymer prepared. - Determination of solubility parameter due to
dispersion, polarity, and hydrogen bonding of the
binder, latex and the polymers prepared. - Determination of equilibrium volume swelling.
- Determination of solvent absorbency.
- Determination of equilibrium solvent contents.
20GRAPHICAL RESULTS
POLYMER RESEARCH LABORATORY
Fig 1 graph for comparison of solid contents of
butadiene binder, commercial latex and styrene
butadiene binder latex synthesized.
21POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 3 Graph b/w Q and d to find Qmax for
butadiene binder.
22POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 4 Graph b/w Q-1ln (Q max/Q) ½ and d of
solvents to find d of butadiene binder.
23POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 5 Graph b/w solvents vs Q, Veq, Sab Seq
for each solvent to compare effect of each
solvent on Q, Veq, Sab Seq for butadiene
binder.
24POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 6 Comparison for Qmax values of Butadiene
Binder, Styrene Butadiene Binder Latex and
Commercial Latex.
25POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 7 Comparison for d values of Butadiene
Binder, Styrene Butadiene Binder Latex and
Commercial Latex. (Batch 2 4 coagulated).
Fig 7 Comparison for dh values of Butadiene
Binder, Styrene Butadiene Binder Latex and
Commercial Latex. (Batch 2 4 coagulated).
26POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 7 Comparison for dd values of Butadiene
Binder, Styrene Butadiene Binder Latex and
Commercial Latex. (Batch 2 4 coagulated).
Fig 7 Comparison for dp values of Butadiene
Binder, Styrene Butadiene Binder Latex and
Commercial Latex. (Batch 2 4 coagulated).
27POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 10 Effect of change in Styrene concentration
on d values and comparison with d values of
Butadiene Binder and Commercial Latex.
Fig 10 Effect of change in Styrene concentration
on dh values and comparison with dh values of
Butadiene Binder and Commercial Latex.
28POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 10 Effect of change in Styrene concentration
on dp values and comparison with dp values of
Butadiene Binder and Commercial Latex.
Fig 10 Effect of change in Styrene concentration
on dd values and comparison with dd values of
Butadiene Binder and Commercial Latex.
29POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 14 Effect of change in initiator type on d
values and comparison with d values of Butadiene
Binder and Commercial Latex.
Fig 14 Effect of change in initiator type on dh
values and comparison with dh values of
Butadiene Binder and Commercial Latex.
30POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 14 Effect of change in initiator type on dd
values and comparison with dd values of
Butadiene Binder and Commercial Latex.
Fig 14 Effect of change in initiator type on dp
values and comparison with dp values of
Butadiene Binder and Commercial Latex.
31POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 18 Effect of change in emulsifier type on dd
values and comparison with dd values of
Butadiene Binder and Commercial Latex.
Fig 18 Effect of change in emulsifier type on dh
values and comparison with dh values of
Butadiene Binder and Commercial Latex.
32POLYMER RESEARCH LABORATORY
GRAPHICAL RESULTS
Fig 18 Effect of change in emulsifier type on dd
values and comparison with dd values of
Butadiene Binder and Commercial Latex.
Fig 18 Effect of change in emulsifier type on dp
values and comparison with dp values of
Butadiene Binder and Commercial Latex.
33CONCLUSIONS
POLYMER RESEARCH LABORATORY
- Solid contents of the polymer increase after
copolymerization reaction. - Densities of the polymer also increase after
copolymerization reaction. - In case of binder the major contribution is of
solubility parameter due to dispersion. - In case of Commercial Latex the major
contribution in solubility parameter is the
hydrogen bonding. - In case of styrene binder Commercial Latex the
major contribution in solubility parameter is the
hydrogen bonding. - Change in initiator type does not affect the
solubility parameter values of synthesized latex
in comparison with Binder and Commercial Latex. - Increase in the concentration of the emulsifier
increase the polymerization rate.
34FUTURE RECOMMENDATIONS
POLYMER RESEARCH LABORATORY
- Cross-link density (Ve)
- Average molecular weight of the polymer chains
between cross-linked points (Mc) - v ln (1 v2,s ) v2,s X v22,s Ve
- Mc V1 (v1/32,s v 2,s/2)
-
- Mc - ( 1 2 / F ) V1 v2/32r v1/32m
- v ln(1 v2m) v2m Xv22m
-
- Mc - V1 dp v1/3s vs/2
- ln ( 1 vs ) vs X v2s
- X Xs XH 0.34 V1/ RT ( dpolymer -
dsolvent)2
35POLYMER RESEARCH LABORATORY
CHRACRTERIZATION INSTRUMENTS
- Fourier Transform Infra Red Spectroscopy (FTIR)
- Gel Permeation Chromatograph (GPC)
- Themomechanical Analyzer (TMA)
- Thermogravimitric Analyzer (TGA)
- Diffrential Scanning Calorimeter (DSC)
- Rheometer
36POLYMER RESEARCH LABORATORY
- Polymer Synthesis Pilot Plant
- Injection Moulding
- Blow Moulding
- Pipe Extruder
- Sheet Extruder
- Film Extruder
END PRODUCT FORMATION
37ACKNOWLEDGEMENTS
POLYMER RESEARCH LABORATORY
- This work is supported by HEC, Pakistan.
- Miss Saba Bahzad Khan (ICET PU LHR)
- Mr. Muhammad Aslam Butt of Reliance Polymer
Industries Lahore - Dr. Khurram Khawaja and Mr. Muhammad Tahir Butt
of Anwar Khawaja Industries Sialkot - Mr. Ibrar Mr. Naveed of Shafi Reso Chem Lahore
38THE END WITH THANKS TO ALL PARTICIPANTS