Title: An extensive aging study of bakelite RPC
1An extensive aging study of bakelite RPC
- Danilo Domenici
- University of Rome
- Tor Vergata and INFN
2Overview
- Historical review of detector characteristics
and performances - Test setup at Gamma Irradiation Facility (CERN)
- Measuring the bakelite resistivity
- Effects of aging on resistivity
- Flowing of humid gas
- Effects of aging on rate capability
Pisa Meeting May 27, 2003
Danilo Domenici
2
3Some history
- In 1998 RPCs were proposed for LHCb Muon
Detector, in the regions with a maximum flux
density of 750 Hz/cm2 - In 1999 2 RPCs prototypes were built with
identical characteristics - bakelite electrodes with bulk resisistivity ?
1010 Ocm - 50 x 50 cm2 sensitive area
- The rate capability of these detector was
initially measured to be gt 3
kHz/cm2 (NIM A 456 (2000) 95) - In 2001 an extensive test started at GIF to
study aging effects on rate
capability
Pisa Meeting May 27, 2003
Danilo Domenici
3
4Test setup at GIF
Source characteristics 662 KeV ? from
740 GBq 137Cs Counting rate 1?3 kHz/cm2 at
1 m from the source
2001 A in pos 1, B in pos 2002-2003 both in
pos 1
1 aging position 2 reference position 3
testbeam position
- The irradiation is measured by the accumulated
charge per cm2 (Qacc) we had previously shown
that the resistivity of bakelite slabs is not
affected by pure irradiation up to doses of 20
kGy - Since the rate capability is inversely
proportional to ?, this has been the monitored
quantity
Pisa Meeting May 27, 2003
Danilo Domenici
4
5Measurement of resistivity
- We have developed a simple method to measure ?
continuously at the GIF - It requires the detector to be exposed to large
flux of radiation - The model is described in G. Carboni et al. NIM
A 498 (2003) 135 - It is based on the hypothesis that all the
physical properties of an RPC
must depend on
Vgap V0 - RI
S
d
- R depends exponentially on the temperature
- For bakelite we measured the value a 0.12
0.01
Danilo Domenici
5
Pisa Meeting May 27, 2003
6Measurement of resistivity
Current saturation with flux
Current linearity with HV
- For fixed V0 the current depends exponentially
on the
temperature through R
Danilo Domenici
6
Pisa Meeting May 27, 2003
7Current vs time
Current drawn at 10800 V corrected by temperature
8 months of irradiation 0.4 C/cm2 acc. charge
(RPC A) In the same period RPC B was used as
reference and accumulated only 0.05 C/cm2
- I decrease by a factor 6
- ? increase by the same factor
Qacc0.4 C/cm2
jan 01
aug 01
Danilo Domenici
7
Pisa Meeting May 27, 2003
8? vs time 1999-2001
irradiating
- Remarks
- Large increase for RPC A
- Evidence of increase not related to irradiation
for both
Danilo Domenici
8
Pisa Meeting May 27, 2003
9? vs time 2002
- Test both detectors now installed close to the
source to measure ?
continuously - Only 0.05 C/cm2 accumulated charge (large ? ?
low current) - Both detectors show a steady increase of ? with
time - Hypothesis drying up of bakelite (see also I.
Crotty et al., NIM A 346, 1994)
Danilo Domenici
9
Pisa Meeting May 27, 2003
10? vs time 2003 humid gas
no flow
humid flow
- 1.2 of vapor H2O added to the usual gas mixture
- Clear effect of humid gas, (see also ALICE 2002
results) but - on RPC B there is a sharp decrease of ?
- on RPC A the effect is much reduced
- ? rapidly resume to old values when dry gas flow
is restored
Danilo Domenici
10
Pisa Meeting May 27, 2003
11Effects on rate capability
- We define a RPC detector capable to stand a
given rate if - efficiency gt 95 (trigger requirement)
- at least 400 V plateau (safety requirement)
- HV lt 11000 (streamer limitation)
The detectors were tested at GIF by means of X5
muon beam
Danilo Domenici
11
Pisa Meeting May 27, 2003
12GIF test August 2001
Resistivity at 20 ºC ?A 39 x 1010 Ocm Rate
capability at 20ºC 640 Hz/cm2
Danilo Domenici
12
Pisa Meeting May 27, 2003
13GIF test July 2002
Resistivity at 20 ºC ?A 110 x 1010 Ocm Rate
capability at 20ºC 200 Hz/cm2
Danilo Domenici
13
Pisa Meeting May 27, 2003
14Testbeam summary
- Except for the 1999 data (affected by large
uncertainties) the values are in agreement with
the 1/? dependence of rate capability
Danilo Domenici
14
Pisa Meeting May 27, 2003
15Conclusions
- A method has been developed and applied to
measure RPC bakelite resistivity on-line, during
chamber operation - Aging effects on bakelite RPCs have been
extensively studied for 3 years on two
identical detectors with building resistivities
around 1010Ocm - After 2 years operation ? had already increased
to 100 x 1010Ocm reaching the value of 200 x
1010Ocm at the end of the third year - Although irradiation contributes to the
resistivity increase, we
believe the effect is mainly related to dry gas
flow - Humid gas has been flowed with different
response RPC B
shows a sharp decrease of resistivity, whereas in
RPC A the effect is very much
reduced - Restoring dry gas flow has resulted again in
fast resistivity increase - Flow of humid gas doesnt appear to be a
practical method to recover detector
performances - Rate capability dropped from few kHz/cm2
to
about 200 Hz/cm2 ? no RPCs in LHCb!
Danilo Domenici
15
Pisa Meeting May 27, 2003