LEGIONELLA - PowerPoint PPT Presentation

1 / 33
About This Presentation
Title:

LEGIONELLA

Description:

Legionella = water-borne bacteria. Naturally widespread in ... Quarterly shower head de-scaling. 6 monthly storage inspections. Annual review of risk assessment ... – PowerPoint PPT presentation

Number of Views:2323
Avg rating:3.0/5.0
Slides: 34
Provided by: ntnwb
Category:
Tags: legionella

less

Transcript and Presenter's Notes

Title: LEGIONELLA


1
LEGIONELLA
  • MANAGEMENT CONTROL

Nemco
U T I L I T I E S
2
LEGIONELLOSIS
  • Legionella water-borne bacteria
  • Naturally widespread in the environment
  • Over 50 different species identified
  • 20 known to cause disease in man
  • Legionella pneumophila
  • Legionnaires Disease
  • Pontiac Fever / Lochgoilhead Fever

3
LEGIONELLA
  • Temperature range 20 - 50C
  • Proliferates at 37 C
  • Requires nutrients
  • Slow moving / stagnant water
  • Poorly managed water system
  • perfect environment

4
LEGIONNAIRES DISEASE
  • American Legion Convention, July 1976
  • 182 cases - 29 died
  • 38 cases in passers by (5 died)
  • 200-300 cases/year - England Wales
  • 10-12 mortality rate
  • Respiratory disease

5
SYMPTOMS
  • Head muscle ache
  • Tightness in chest
  • Dry cough
  • Sickness diarrhoea
  • Confusion / delirium
  • Coma
  • Death

6
AT RISK GROUPS
7
CHAIN OF EVENTS
  • Bacteria present in water system
  • Slow moving / stagnant water
  • Adequate food source
  • Temperature range 20-50C
  • Aerosol formed
  • People present

8
RISK AREAS
  • Hot cold water systems
  • Cooling Towers Air Conditioning
  • Storage Cisterns
  • Calorifiers
  • Deadlegs
  • Showers
  • Spa pools

9
SHOWERS
Operate at desired temps Poor hygiene Infrequently
used Prone to scaling Create aerosol
10
DEAD LEGS
Stagnant water Ambient temps Breeding ground
11
STORAGE TANKS
Over capacity Stagnation Out of sight Poor
flow Ambient temps
12
(No Transcript)
13
(No Transcript)
14
(No Transcript)
15
CALORIFIERS
Can run at critical temps Thermal
stratification Sludge build up
16
COOLING TOWERS
Run at ideal temps Open to elements Contamination
via water supply Intermittent use Drift affects
wide area
17
RISK MANAGEMENT
  • Risk assessment
  • Regular monitoring
  • Temperature control
  • Water Treatment
  • Maintenance Cleaning
  • Annual review
  • Awareness

18
CASE HISTORY
  • Hospital outbreak - Glasgow 1992
  • 1 patient died
  • Source fire hose
  • Deadleg
  • Need for awareness

19
CASE HISTORY
  • Flower Show - The Netherlands 1999
  • 242 Cases - 28 died
  • Source - Whirlpool Spa exhibit
  • Fed from hose
  • Where could it strike next?

20
THE LAW
  • Health Safety at Work Act (1974)
  • COSHH Regulations (1999)
  • Notification of Cooling Towers Regulations (1992)
  • Approved Code of Practice (1992)
  • Revised ACOP January 2001

21
RESPONSIBILITY - ACOP
  • Identify assess sources of risk
  • Prepare scheme to prevent/control the risk
  • Implement manage control programme
  • Keep Records
  • Appoint a responsible person

22
Responsible Person
  • Managerially responsible for implementation
    supervision
  • Ensure all those involved are trained and
    competent
  • Manage contractors and suppliers
  • Maintain records
  • Ensure regular reviews are carried out

23
PROSECUTIONS
  • 1988 - BBC London
  • 70 reported cases
  • 2 people died
  • Source of bacteria cooling tower
  • Fined 3,600 / Costs 3,200
  • 26,400 in compensation to taxi driver

24
CORPORATE MANSLAUGHTER
  • Local Authorities Individuals
  • Barrow-in-Furness Manager charged
  • 7 counts of manslaughter could have got life
    for gross negligence (actually fined 15,000)
  • Council could have received unlimited fine
    (actually fined 125,000 with costs of 90,000
  • Service contract lapse cooling tower
  • 172 cases, 7 people died (Aug 2002)

25
THE CASE SUMMARY
  • May 01 Streamline contract cancelled
  • Jun 01 council H S mgr asked to do checks but
    refuses
  • Jul 01 GB appoints Interserve but contract
    omits dosing and dipslides
  • Jan-Jun 02 Engineer warns of danger
  • Aug 02 Outbreak declared

26
KEY FACTORS
  • Poor communication (internally)
  • Responsibilities not defined
  • Lack of training
  • Failure to record meetings / conversations
  • Insufficient contract documentation
  • Poor advice / management
  • Risk assessment not carried out

27
COST TO BUSINESS
  • Sick pay
  • Loss of production / skills
  • Cost of an investigation
  • Prosecution Civil Action
  • Bad publicity - loss of business
  • Employee de-motivation

28
LEGIONELLA MONITORING
  • Programme for continual risk assessment
  • Identification of problem areas
  • Demonstrate effective temperature control
  • Visual inspection - cleanliness
  • Compliance with current guidance

29
SCHEME FOR CONTROL
  • DOMESTIC WATER SYSTEMS
  • Weekly flushing - infrequent use services
  • Monthly temperature monitoring - sentinel taps
    calorifiers
  • Quarterly shower head de-scaling
  • 6 monthly storage inspections
  • Annual review of risk assessment
  • Cleaning and disinfection as required

30
LOGBOOK RECORDS
  • Lines of communication responsibility
  • Original risk assessment
  • Asset list - uniquely identified water services
  • Schematic drawings of water system
  • Scheme for control
  • Monitoring flushing records
  • Records of remedial or maintenance work
  • Emergency procedures

31
CONTRACT MANAGEMENT
  • Use registered suppliers - Code of Conduct
  • Check training records / CVs
  • Ask for references
  • Agree document levels of service
  • Agree document areas of responsibility
  • Review contract at agreed intervals
  • Check log book records regularly

32
FUTURE TRENDS
  • Rise in susceptible individuals
  • Increased installation of TMVs
  • (new building regs required on all baths /
    showers)
  • MRSA increased use of alcohol gel
  • Office water coolers / boilers
  • IR no touch taps (low flow areas)
  • Increase in solar heating installations
  • Global warming
  • Rapid detection techniques are improving

33
HELP ADVICE
  • For any help or advice
  • HELPLINE 0800 0741237
Write a Comment