Housing Policy - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

Housing Policy

Description:

Car parking width - Where car parking is adjacent to the home, it should be ... space for turning a wheelchair in dining areas and living rooms and adequate ... – PowerPoint PPT presentation

Number of Views:25
Avg rating:3.0/5.0
Slides: 13
Provided by: lcc18
Category:
Tags: housing | policy

less

Transcript and Presenter's Notes

Title: Housing Policy


1
Housing Policy Meeting the needs of all of the
community.
  • Michael Kirby
  • Chief Planning Officer
  • Lancashire County Council

2
Background to Policy
  • Government Policy.
  • Regional policy.
  • Local (District Policies).

3
The Policy Framework
  • Influencing the development of policy
  • How the RSS has developed.
  • Relevant regional policies

4
Policy L4 Regional Housing Provision
  • Local authorities should monitor and manage the
    availability of land released in plans and
    strategies and through development control
    decisionsin doing so they should
  • Work in partnership with developers and other
    housing providers to address the housing
    requirements of different groups
  • Ensure that all new homes are built to the
    Lifetime Homes and code for sustainable homes
    standards

5
So what is the Standard?
  • 16 Criteria
  • Car parking width - Where car parking is adjacent
    to the home, it should be capable of enlargement
    to attain 3.3m width
  • Access from car parking - The distance from the
    car parking space to the home should be kept to a
    minimum and should be level or gently sloping.
  • Approach Gradients - The approach to all
    entrances should be level or gently sloping.

6
The Lifetime Homes Standard (Cont)
  • External entrances - All entrances should be
    illuminated, have level access over the threshold
    and have a covered main entrance.
  • Communal Stairs and Lifts - Communal stairs
    should provide easy access and, where homes are
    reached by a lift, it should be fully accessible.

7
The Lifetime Homes Standard (Cont)
  • Doorways and hallways - The width of internal
    doorways and hallways should conform to Part M,
    except that when the approach is not head on and
    the hallway width is 900mm, the clear opening
    width should be 900mm rather than 800mm. There
    should be a 300mm nib or wall space to the side
    of the leading edge of the doors on entrance
    level.

8
The Lifetime Homes Standard (Cont)
  • Wheelchair Accessibility - There should be space
    for turning a wheelchair in dining areas and
    living rooms and adequate circulation space for
    wheelchairs elsewhere.
  • Living Room - The living room should be at
    entrance level.
  • Entrance Level Bed space - In houses of two or
    more storeys, there should be space on the
    entrance level that could be used as a convenient
    bed space.

9
The Lifetime Homes Standard (Cont)
  • Entrance Level WC and Shower Drainage - In
    houses with three or more bedrooms, and all
    dwellings on one level, there should be a
    wheelchair accessible toilet at entrance level
    with drainage provision enabling a shower to be
    fitted in the future. In houses with two bedrooms
    the downstairs toilet should conform at least to
    Part M.
  • Bathroom and WC walls - Walls in the bathroom and
    WC should be capable of taking adaptations such
    as handrails.

10
The Lifetime Homes Standard (Cont)
  • Stair Lift/Through Floor Lift - The design should
    incorporate provision for a future stair lift and
    a suitably identified space for a through the
    floor lift from the ground floor to the first
    floor, for example to a bedroom next to the
    bathroom.
  • Tracking Hoist Route - The design and
    specification should provide a reasonable route
    for a potential hoist from a main bedroom to the
    bathroom.

11
The Lifetime Homes Standard (Cont)
  • Bathroom Layout - The bathroom should be designed
    for ease of access to the bath, WC and wash
    basin.
  • Window Specification - Living room window glazing
    should begin no higher than 800mm from the floor
    level and windows should be easy to open/operate.
  • Controls/Fixtures and Fittings - Switches,
    sockets, ventilation and service controls should
    be at a height usable by all (i.e. between 450mm
    and 1200mm from the floor).

12
LDFs and Community Involvement
  • All Councils will produce a Local Development
    Framework.
  • We need to ensure the evidence base is sound.
  • We need to ensure that the plans meet the needs
    of all sectors of the community.
  • There is a need to get involved in the process.
Write a Comment
User Comments (0)
About PowerShow.com