Title: 4100 Presentation
1PReasy 4100
A New Beginning
24100 Series
- A Universal, Front programmable and
Cost-effective series of products for Signal
Conditioning and Still High Quality (Namur NE-21,
PR-Precision and 5 year Warranty) - Thus Dedicated for Installers, Panel builders,
machine Builders and of course all types of End
Users.
34100 Series
- The Interface
- Input
- Output
- Relay Function
- Error Handling and Diagnostics
- Advanced Features
44100 Universal transmitters / trip amplifier
- Universal Input
- Analogue Output Voltage and Current
- Universal supply 21,6-253 VAC / 19,2 300 VDC
- 2 relays with programmable functions
- Sensor error indication via Display Front or LED
- And Programmable via display front 4501
- No Manual Needed Menu Structure PR Guided!
- Approvals CE, LVD, UL-508 (Autumn 2005)
- Safety Fulfilling the requirements for SIL-2
INPUT OUTPUT
X
54100 The Programming Interface
- Run Mode
- Display of Input value in eng. Units
- Display Output Value or TAG
- Programming Mode
- Change value with Arrows
- Validate with OK
- The Menu Guides you to the Next Item gt Thats
PReasy - Error Mode
- All error indications will be shown in the 2nd
line together with a Flashing Backlight. The
Flashing backlight can be turned off by pressing
OK.
249.0
VOLT
SE.BR
Both Arrows TAG / Ana.Out Toogle
Flashing BacklightWith Errors
C
INTYPE
Error TEXT
15.2 mA
HELP TEXT
Prog-Mode
Error-Mode
Run-Mode
64100 The Programming Interface Status Line
- The Status Line has 4 symbols
- 1 Indicates the status of the Relay 1 Contact
Open or Closed - The 1 can be flashing, if the relay is in the
Delay period - 2 Indicates the status of the Relay 2 Contact
Open or Closed - The 2 can be flashing, if the relay is in the
Delay period - The arrow shows the tendancy of the Input Signal
- The Com-symbol indicates if the 4501 is running
correctly
249.0
C
15.2 mA
Run-Mode
74100 The Display Engineering Units
- C in/s bar kV F ft/s mbar
- mV K in/min kJ Ohm m ft/min
- Wh S cm in/h MWh uS mm
- ft/h kWh ft rpm W m3/min
- in Hz GW m3/h yd t MWL/s
- m3 kg kW L/minL g hp L/h
- s N A gal/min min Pa kA
- gal/h m/s MPa mA t/h m/min kPa
- uA mol m/h hPa V pH
Run-Mode
84100 The Programming Interface - The PR Guided
Menu
PR GUIDED Menu Structure 4100 3 Lines 5714 1
Line
Traditional Menu Structure Often 1 Line
Short Cut to fastset Short Cut to Advanced
Features
Start
Start
Type
Range
Input
Type
Range
Input
Relays
Setp
Hyst
Relays
Value
Output
Thats PReasy!
Output
- User Problems
- Where am I?
- Whats Next?
- What do I need to do now? What do I miss?
- User Advantages
- No need to Know where You are!
- Only 1 way Through (Fwd or Bwd)
- PR Guided makes sure You will get through all
Necessary Items!
94100 Universal Input
- Current 0-20 mA 4-20 mA
- Voltage 0-1V 0,2-1V 0-5V 1-5V 0-10V 2-10V
- Lin.R. 0-10.000 Ohm (2,3 and 4 wire )
- Potentiometer 10 O 100 kO (3 wire)
- Loop Supply 16V for 2-wire Transmitter
INPUT OUTPUT
X
104100 Universal Input - Temperature
- Pt x and Ni X
- 2,3 and 4 wire connections
- Pt 10, 20, 50, 100, 200, 400, 500, 1000
- Ni 50, 100, 120, 1000
- TC
- 13 Types, including Russian L (LR)
- Internal CJC (Always Mounted)
INPUT OUTPUT
X
114100 TC- Input Cold Junction Compensation
- Internal CJC Always Mounted
- Precision
- Max lt/-1,0 C (-20 C - 60 C)
- Max Error (0,0053 C x Amb.Temp)0,68 C
- Safety
- The unit will make max. comp. of -20 C and 80
C respectively, even though the CJC sensor
element should indicate a higher or lower
temperature.
INPUT OUTPUT
X
124100 Analogue Output
- Current
- 0-20 mA 20-0 mA
- 4-20 mA 20-4 mA
- Max Charge 800 O
- Over/Under Range Limits 3,8 mA / 20,5 mA
- Sensor Error Indication 0/3,5mA or 23mA
- Voltage (calibrated with Internal Shunt)
- 0/0,2-1V 1-0,2/0V 0/1-5V 5-1/0V 0/2-10V 10-2/0V
- Sensor Error Indication No
INPUT OUTPUT
X
134100 Two Independant Relay Outputs
- Relay Functions (The 2 relays can have different
functions) - Setpoint (SETP) (Fastset Possibility)
- Window (WIND)
- Input Error (ERR)
- Power (POW)
- OFF
INPUT OUTPUT
X
144100 Relay Units
- For all Functions
- For Temp Inputs the unit is C or F
- For other inputs, you can choose between
- DISP Display Units
- PERC Percentage
INPUT OUTPUT
X
154100 Relay Output SETP function
- FUNCTION SETP Setpoint
- Function N.O. / N.C.
- Setpoint
- Action Increase or Decrease
- Hysteresis 0,1 to 25 of span or 1 count to 3000
counts (max 25) - On-Delay in Seconds (0- 3600s)
- Off-Delay in Seconds (0- 3600s)
- Error action Hold,Open,Close, None
INPUT OUTPUT
X
164100 Relay Output WIND function
- FUNCTION WIND Window
- Contact
- O.I.W. Open In Window
- C.I.W Closed in Window
- Setpoint Low
- Setpoint High
- Hysteresis 0,1 to 25 of span or 1 count to 3000
counts (max 25)
INPUT OUTPUT
X
174100 Relay Output ERR function
- FUNCTION ERR Error
- Action in case of Error
- Hold,Open,Close, None
INPUT OUTPUT
X
184100 Relay Output POW function
- Function POW Power
- The Relay will be CLOSED when the module is
powered. - The Relay will be OPEN when the module is NOT
powered
INPUT OUTPUT
X
194100 Relay Output OFF function
- Function OFF
- The Relay will be deactivated!
INPUT OUTPUT
X
204100 Series
- Error Indication, Detection
- Auto Diagnostics
214100 Error Detection Out of A/D converter range
- Indicated by IN.LO or IN.HI
- Voltage Input1 lt-25 mV or gt1,2V
- Voltage Input2 lt-25 mV or gt12V
- Current Input lt-1,05mA or gt25,05mA
- POTM Input lt-0,5 or gt100,5
- LIN.R input1 lt-10O or gt1075O
- LIN.R input2 lt-10O or gt110kO
- TEMP ltPoly-2 C or gtPoly2 C
224100 Error Detection Sensor Error
- Indicated by SE.BR (break) or SE.SH (shortage)
- Voltage None
- 4-20mA SE.BR - Input lt3,6mA or gt 21mA
- POTM SE.BR - Input gt126k O (Each Wire)
- LIN.R1 SE.BR gt 875 O
- LIN.R2 SE.BR gt 11 kO
- TC SE.BR gt 750 kO
- Pt and Ni SE.BR gt 15 kO
- SE.SH lt 15 O (Not for
Pt10, Pt20 and Pt50)
234100 Error Detection Display Over/Under Range
- Display over/under range, indicated by -1.9.9.9
or 9.9.9.9 - NB the minimum/maximum values on the Display is
-1999, 9999 respectively.
244100 Error Indication Resumed With 4501
- Out of A/D converters Range
- Flashing IN.LO or IN.HI
- Display Over/Und range indication
- Flashing -1.9.9.9 or 9.9.9.9
- Sensor Break
- Flashing SE.BR
- Sensor Shortage
- Flashing SE.SH
254100 Error Indication With LED
- The unit is continuously verifying its own State
of Health, thus Increasing Safety. - Error Indication with 1 Green/Red LED on Front
- Green Flashing 13 Hz Normal
- Green Flashing 1 Hz Sensor Error
- Green On not Flashing Internal Error
- Red On not Flashing Fatal Error
- Return Product to PR
264100 Auto Diagnostics With 4501 Display
- The unit is continuously verifying its own State
of Health, thus Increasing Safety. - Error Indication with Display Mounted
- HW.ER Permanent error in uC/AD converter
- CJ.ER CJC sensor Failure
- RA.ER error in RAM (Memory)
- FL.ER Error in Flash Memory
- AO.ER Error in analogue Measurement
- TY.ER Trying to Load a configuration from for
example a 4114 to a 4116. - CO.ER Com Error between 4501 and 41xx
- PW.ER Error in Internal Power
274100 Series
284100 Advanced Features
- It is possible to enter Advanced Setting in
Beginning of the Menu structure - Memory
- Display
- Calibration
- Simulation
- Password
- Language
294100 Advanced Features MEMORY (MEM)
- With this feature you can easily copy a
configuration from one module to another. - Memory (MEM)
- SAVE or LOAD
- Save, saves the Product Configuration in the
Front - Load, uploads the configuration in the front to
the next Product - NB Process Calibrations are not copied.
304100 Advanced Features DISPLAY (DISP)
- Contrast (CONTRA)
- 0 to 9
- Light (LIGHT)
- 0 to 9
- TAG (Exception 1st and 2nd line swithced)
- 6 characters Alpha Numerique
- LINE 3 (Selection of Indication in 3rd Line)
- TAG or A.OUT
314100 Advanced Features CALIBRATION (CAL)
- 2 Point Process Calibration for ALL input Types
- CAL.LO (not necessarily 0)
- Yes or No, if Yes then
- Affect the LOW value you want to calibrate to the
Input of the Product. - Preset the Correct Value in Display Units.
- CAL.HI (not necessarily 100)
- Yes or No, if Yes then
- Affect the HIGH value you want to calibrate to
the Input of the Product. - Preset the Correct HIGH Value in Display Units.
- NB A new Process Calibration will not consider
an eventual previous process calibration.
324100 Advanced Features SIMULATION (SIM)
- Simulate the Input value in Display Units
- Enable Simulation (EN.SIM)
- Yes or No
- If Yes, then Simulate the Input value in Display
Units - And see what happens to the Output and the Relays
- Relay Simulation (REL.SIM)
- Use the arrows to toggle the two relays
independently
334100 Advanced Features PASSWORD (PASS)
- Enable Password (EN.PASS)
- Yes or No
- If Yes, then enter Password
- Enable Fastset (EN.FAST)
- Yes or No
344100 Advanced Features LANGUAGE (LANG)
- Select the Language of the Help Texts
- Language (LANGUA)
- DE,DK,ES,FR,IT,SE,UK
354100 Compared to 5000 and 2200 Series Whats New?
- Same As 2202, 2204, 2231, 2237, 2238, 2241,
2271, 2284 - But which Functionality can be found in he 4000
but not in the 2200 series? - Pt100 with 2 Relays
- TC transmitter
- TC transmitter with 2 Relays
- Relay with Loop Supply
- ReadOut of Input and Output Values (in
Engineering Units) - 2-Point Process Calibration (w.Buttons not
Potentiometers) - And Much more