Prompt GammaRay Imaging Using the GEANT4 Code - PowerPoint PPT Presentation

1 / 22
About This Presentation
Title:

Prompt GammaRay Imaging Using the GEANT4 Code

Description:

Prompt Gamma-Ray Imaging Using the GEANT4 Code. Libai Xu and Robin Gardner ... yields are 1.4 X 1010 (B) and 5.9 X 1010 (Gd) compared to 2.2 X 1010 for SPECT ... – PowerPoint PPT presentation

Number of Views:64
Avg rating:3.0/5.0
Slides: 23
Provided by: neN6
Category:

less

Transcript and Presenter's Notes

Title: Prompt GammaRay Imaging Using the GEANT4 Code


1
Prompt Gamma-Ray Imaging Using the GEANT4 Code
  • Libai Xu and Robin Gardner
  • Center of Engineering Applications of
    Radioisotopes
  • Department of Nuclear Engineering
  • North Carolina State University
  • For Presentation at CEAR Annual Meeting 2007
  • Oct 2, 2007

2
OUTLINE
  • Introduction
  • Prompt Gamma-ray Modeling
  • Prompt Gamma-ray Imaging
  • Conclusions
  • Future work

3
Introduction
  • Prompt Gamma Neutron Activation Analysis
  • Identify elements and their abundance
  • Prompt Gamma-ray Imaging
  • Identify elements, abundances, and positions

4
System Design
5
Potential Application 1
  • NCT (Neutron Capture Therapy) for Cancer
    treatment
  • Selectively deliver 10B or Gd to the tumor
  • Irradiate the tumor region with low energy
    neutrons
  • The short range of the 10B(n,a)7Li reaction
    products restricts most of the dose to the tumor
    cells

?
Coderre, J. A. and Morris, G. M. 1999. The
radiation biology of boron neutron capture
therapy Radiat. Res. 151 1-18
6
Potential Application 2
  • Small animal imaging

7
Prompt Gamma-ray Modeling
  • Currently Available Codes
  • MCNP5
  • CEARCPG
  • GEANT4
  • Requirements for PGI
  • Must be capable of simulating coincident gamma
    rays
  • Must be capable of simulating repeated
    structures
  • 3-D Visualization

8
Neutron Capture Reaction
Prompt Gamma-ray Modeling
12C
13C
9
Prompt Gamma-ray Modeling Geant4 Modification
10
Hg prompt gamma-ray spectrum
Prompt Gamma-ray Modeling
11
Neutron Capture Reaction by Geant4
Prompt Gamma-ray Modeling
  • Prompt gamma rays are produced in coincidence.
  • 2) Prompt gamma-ray intensity information agrees
    with ENSDF

12
Prompt Gamma-Ray Yields
Prompt Gamma-ray Modeling
13
Prompt Gamma-Ray Yields
Prompt Gamma-ray Modeling
Capture reactions for each component in soft
tissue (per 1.E6 thermal neutrons)
14
Neutron Capture Therapy106 thermal neutronsFor
neutron fluence of 1012 yields are 1.4 X 1010 (B)
and 5.9 X 1010 (Gd) compared to 2.2 X 1010 for
SPECT
Prompt Gamma-ray Modeling
15
Prompt Gamma-ray Imaging
  • Physical collimations

sample
Detector plane
Pinhole
Coincident detector
16
Prompt Gamma-ray Imaging
17
Prompt Gamma-ray Imaging
18
Raw Projection Images
Prompt Gamma-ray Imaging
370kev prompt gamma rays
19
Coded Aperture
20
Conclusions
  • PGI is good for H, B, Gd, or Hg
  • Either pinhole or coded aperture may be used for
    imaging coded aperture appears to be the best

21
Future Work
  • Coded Aperture
  • Simulation Code Development
  • Develop and Test a Prototype

22
THANKS
Write a Comment
User Comments (0)
About PowerShow.com