Title: The Opportunity
1(No Transcript)
2The Opportunity
3- Percentage of Annual Electricity Usage
- within Office Building Environments
25 to 56 for Lighting
4State Adoption of Energy Codes that Require
Automated Lighting Controls
38 STATES NOW REQUIRE AUTOMATED CONTROLS
5The Dilemma
6The Lighting Dilemma
How can you address energy savings, meet energy
codes, maximize lighting performance and deliver
a quality customer experience?
Flexible space usage
Different work schedules
Lighting quality
New renovations
Daylight integration
Load shedding
Cost effective
Lower energy cost
Easy to use
7The Lighting Dilemma
Whats the best current solution?
Advantages
Solutions
Disadvantages
Occupancy Sensors
- Lower cost
- No programming
- No load shed capabilities
- Application-specific technologies
- Overrides are difficult
- Requires programming
- Complicated to specify and install
- Extra wiring required
- Well-known technology
- Requires entire building
- control
Relay System
Dimming System
- Complicated to operate
- Not used often for energy mgmt.
- Higher cost for ballast and system
- Occupant comfort
- Flexible space usage
- Load shed capable
8The Lighting Dilemma
Typical examples
- Intelligence is concentrated at the
- central panel
- Requires wiring to Home Run to the
central panel for every zone - Line voltage and low voltage must be
kept separate per NEC - Wall controllers must be wired directly
back to the panel or daisy chained back to - the panel with special network cable
- Occupancy sensors and photocells are wired
back to the panel - All must be assigned and programmed
after installation
9The Lighting Dilemma
Conclusion Current lighting controls systems
are not ready for the mass market of typical
customer and installers
- Complicated to design or install
- Difficult to operate
- Often expensive
- Offer only a partial or limited solution
10The SIMPLY5 Solution
11The SIMPLY5 Solution
- A New Approach
- Current systems address energy management
- strictly from a controls viewpoint.
- SIMPLY5 functions as a whole system, adding
- intelligence to highly efficient lighting
fixtures and - controls components to offer a complete solution
- that is easy for everyone.
12The SIMPLY5 Solution
SIMPLY5 is a new approach that required new
thinking
Strategic Industry Partnership
13The SIMPLY5 Solution
- What does this New Approach offer?
- Simple installation and operation
- Greater occupancy flexibility
- Energy savings made easy
- - Local and state energy code compliance
14Components
15The SIMPLY5 Solution
- Intelligent Junction Box
- Coordinates lighting demand, load shedding,
auto-configuration of lights, wall stations,
and sensors - Routes power to room
- Communication with Light Energy Manager for
revised settings, time synchronization
16The SIMPLY5 Solution
- Intelligent Junction Box
- Two Main Models
- S5JB Controls S5 fixtures only
- S5JBS Controls S5 fixtures and Non-dim loads
up to 20A _at_ 277V.
S5JB
S5JBS
17The SIMPLY5 Solution
- Simple Wall Controls
- Intuitive user interface
- Easily gangable for multi-zone control
- Low voltage device
- Class 1 or Class 2 wiring
- Includes Tee connector for easy connection at any
junction point within a zone - Architectural finish
LED Brightness Display
DIM/Bright Rocker Bar
Locator Light
On/Off Push Pad
18The SIMPLY5 Solution
- Light Energy Manager (LEM)
- Controls up to 42 lighting circuits
- Incorporates adaptive time clock control
- Interfaces with building automation
- Contains on board modem
- Enables advanced system features
- Interfaces with Synergy
19The SIMPLY5 Solution
- Sensor Connector
- Use to connect low voltage photocell and/or
occupancy sensors - Includes Tee connector for easy connection at any
junction point within a zone - Allows for auto-configuration with intelligent
junction box
20 RELOC Wiring System
The SIMPLY5 Solution
- Reduces overall labor cost
- Includes all power and control wiring
- All connections are keyed, labeled, and
color-coded - Greatly reduces opportunity for installation
errors - Offers plug-and-play technology
21The SIMPLY5 Premium Warranty will be 5 years on
the ballast and three years on all other
components. Thiswarranty will be offered when
all SIMPLY5 components (fixtures controls
Reloc) are being used on project.
Warranty Statement
The Reloc Advantage
22 The SIMPLY5 Solution
- Efficient Lighting Fixtures
- Low power density easily achieved
- Smart ballast technology
- 7 preset user levels
- Contractor friendly design
Current Fixture Offering
Future Fixture Offering
23The SIMPLY5 Solution
Distributed Intelligence
RT5 Fixture
Sensor Connector
Intelligent Junction Box
Wall Station
Light Energy Manager
RELOC
24The SIMPLY5 Solution
Traditional Systems
SIMPLY5
25Meets Control Energy Codes
YES
Meets Power Density Codes
YES
Override Stations
PLUG PLAY
SIMPLY5 vs. Traditional Systems
Power Wiring
DISTRIBUTED CONTROLS
YES
Progressive Load Shed
RELOC Optimized
YES
Timeclock
ADAPTIVE OR MANUAL
Automatic Configuration
YES
Signal Wiring
EASY
Modem
STANDARD
BACnet
STANDARD
Emergency Lighting
EASY
26SIMPLY5 vs. Other Lithonia Controls Solutions
NO
Conditional Programming
NO
Architectural Preset Dimming
NO
Ballast Control
NO
DMX
or what does SIMPLY5 not do?
PC Control
NO
27 SIMPLY for Everyone
SIMPLY5 is a sustainable solution
28Application Example
29Application Story
School Application Example
- SIMPLY5 Fixture Layout
- 2RT5 28T5 MVOLT
- Other comparison system layout
- 2GT8 3 32 A12
- LB 2 32 MVOLT
- EJ 2 32 MVOLT
30Application Story
School Application Example
- Classroom, Conference Room
- and Private Offices
- - 39 areas with 178 fixtures
- - Fixture Spacing 8 x 10 centers
- Total Square Footage 12,989
31Application Story
School Application Example
32Application Story
School Application Example
- Energy Saving with RT5 SIMPLY5
- Layering SIMPLY5 technology allows for even
greater overall energy savings
33Application Story
School Application Example
- Fixtures on 10 x 10 Centers
- Use 20 less fixtures
- Require 10 less connections
- Save More Energy
- RT5 Only - 48
- RT5 w/ S5 Timeclock - 60
- RT5 w/ S5 Timeclock and occupancy
sensors/photocells 75
SIMPLY5 is 20 less than Occupancy Sensors
34Questions?
35Demo Case Demonstration
36(No Transcript)
37 SIMPLY for Everyone
Simple to Comply
- Meets automated control requirements
- for ASHRAE, IECC, Title 24 and EPAct
- Meets power density requirements
- Incorporates time clock control, occupancy
- sensing and daylight harvesting
38 SIMPLY for Everyone
Simple to Specify
- Lays out similarly to ordinary manual
switching - Involves no complicated wiring
- Needs no completion of relay or dimmer
schedules - Requires no occupancy sensor layouts
39 SIMPLY for Everyone
Simple to Install
- Fast and error-free connections
- No complex Class 2 wiring requirements
- Special communication cables not required
- No large control panels to install or panel
schedules to update - Commissioning is not required to meet code
40 SIMPLY for Everyone
Simple to Expand
- Plug and play components can be added at
- any time
- Easily reconfigured to accommodate changes
- Scalable architecture from single rooms to
- multiple buildings
41 SIMPLY for Everyone
Simple to Use
- Intuitive user interface allows occupants to
adjust - light
- Seven dimming levels available
- Adaptive schedules maximize energy savings
- while minimizing the hassle
42 SIMPLY for Everyone
Simple to Maintain
- Multi-step electronic ballasts with program-
- start features maximize lamp life
- Adaptive electronics stay calibrated
- Commissioning is not necessary when adding
- or replacing components
- Adaptive scheduling accommodates
- occupants usage automatically without
- reprogramming
43 SIMPLY for Everyone
Summary of Benefits
- Empowered components
- Distributed intelligence
- Plug play connectivity
- Simple installation and maintenance
- Greater occupancy flexibility
- Energy savings and sustainable design made easy
- Meets local and state energy codes
44Product Folder Review
45The SIMPLY5 Solution
Why does this new approach make more sense?
- Intelligence distributed throughout the system
- No special wiring requirements and plug-in
connections allow quick and error-free
installation - No complicated commissioning required to meet
codes all thats needed is to set the time. - Advanced features can be configured quickly via
wall stations Light Energy Manager with no
knowledge of installation details