The Opportunity
3
  • Percentage of Annual Electricity Usage
  • within Office Building Environments

25 to 56 for Lighting
4
State Adoption of Energy Codes that Require
Automated Lighting Controls
38 STATES NOW REQUIRE AUTOMATED CONTROLS
5
The Dilemma
6
The Lighting Dilemma
How can you address energy savings, meet energy
codes, maximize lighting performance and deliver
a quality customer experience?
Flexible space usage
Different work schedules
Lighting quality
New renovations
Daylight integration
Load shedding
Cost effective
Lower energy cost
Easy to use
7
The Lighting Dilemma
Whats the best current solution?
Advantages
Solutions
Disadvantages
Occupancy Sensors
  • Lower cost
  • No programming
  • No load shed capabilities
  • Application-specific technologies
  • Overrides are difficult
  • Requires programming
  • Complicated to specify and install
  • Extra wiring required
  • Well-known technology
  • Requires entire building
  • control

Relay System
Dimming System
  • Complicated to operate
  • Not used often for energy mgmt.
  • Higher cost for ballast and system
  • Occupant comfort
  • Flexible space usage
  • Load shed capable

8
The Lighting Dilemma
Typical examples
  • Intelligence is concentrated at the
  • central panel
  • Requires wiring to Home Run to the
    central panel for every zone
  • Line voltage and low voltage must be
    kept separate per NEC
  • Wall controllers must be wired directly
    back to the panel or daisy chained back to
  • the panel with special network cable
  • Occupancy sensors and photocells are wired
    back to the panel
  • All must be assigned and programmed
    after installation

9
The Lighting Dilemma
Conclusion Current lighting controls systems
are not ready for the mass market of typical
customer and installers
  • Complicated to design or install
  • Difficult to operate
  • Often expensive
  • Offer only a partial or limited solution

10
The SIMPLY5 Solution
11
The SIMPLY5 Solution
  • A New Approach
  • Current systems address energy management
  • strictly from a controls viewpoint.
  • SIMPLY5 functions as a whole system, adding
  • intelligence to highly efficient lighting
    fixtures and
  • controls components to offer a complete solution
  • that is easy for everyone.

12
The SIMPLY5 Solution
SIMPLY5 is a new approach that required new
thinking
Strategic Industry Partnership
13
The SIMPLY5 Solution
  • What does this New Approach offer?
  • Simple installation and operation
  • Greater occupancy flexibility
  • Energy savings made easy
  • - Local and state energy code compliance

14
Components
15
The SIMPLY5 Solution
  • Intelligent Junction Box
  • Coordinates lighting demand, load shedding,
    auto-configuration of lights, wall stations,
    and sensors
  • Routes power to room
  • Communication with Light Energy Manager for
    revised settings, time synchronization

16
The SIMPLY5 Solution
  • Intelligent Junction Box
  • Two Main Models
  • S5JB Controls S5 fixtures only
  • S5JBS Controls S5 fixtures and Non-dim loads
    up to 20A _at_ 277V.

S5JB
S5JBS
17
The SIMPLY5 Solution
  • Simple Wall Controls
  • Intuitive user interface
  • Easily gangable for multi-zone control
  • Low voltage device
  • Class 1 or Class 2 wiring
  • Includes Tee connector for easy connection at any
    junction point within a zone
  • Architectural finish

LED Brightness Display
DIM/Bright Rocker Bar
Locator Light
On/Off Push Pad
18
The SIMPLY5 Solution
  • Light Energy Manager (LEM)
  • Controls up to 42 lighting circuits
  • Incorporates adaptive time clock control
  • Interfaces with building automation
  • Contains on board modem
  • Enables advanced system features
  • Interfaces with Synergy

19
The SIMPLY5 Solution
  • Sensor Connector
  • Use to connect low voltage photocell and/or
    occupancy sensors
  • Includes Tee connector for easy connection at any
    junction point within a zone
  • Allows for auto-configuration with intelligent
    junction box

20
RELOC Wiring System
The SIMPLY5 Solution
  • Reduces overall labor cost
  • Includes all power and control wiring
  • All connections are keyed, labeled, and
    color-coded
  • Greatly reduces opportunity for installation
    errors
  • Offers plug-and-play technology

21
The SIMPLY5 Premium Warranty will be 5 years on
the ballast and three years on all other
components. Thiswarranty will be offered when
all SIMPLY5 components (fixtures controls
Reloc) are being used on project.
Warranty Statement
The Reloc Advantage
22
The SIMPLY5 Solution
  • Efficient Lighting Fixtures
  • Low power density easily achieved
  • Smart ballast technology
  • 7 preset user levels
  • Contractor friendly design

Current Fixture Offering
Future Fixture Offering
23
The SIMPLY5 Solution
Distributed Intelligence

RT5 Fixture
Sensor Connector
Intelligent Junction Box
Wall Station
Light Energy Manager
RELOC
24
The SIMPLY5 Solution
Traditional Systems
SIMPLY5
25
Meets Control Energy Codes
YES
Meets Power Density Codes
YES
Override Stations
PLUG PLAY
SIMPLY5 vs. Traditional Systems
Power Wiring
DISTRIBUTED CONTROLS
YES
Progressive Load Shed
RELOC Optimized
YES
Timeclock
ADAPTIVE OR MANUAL
Automatic Configuration
YES
Signal Wiring
EASY
Modem
STANDARD
BACnet
STANDARD
Emergency Lighting
EASY
26
SIMPLY5 vs. Other Lithonia Controls Solutions
NO
Conditional Programming
NO
Architectural Preset Dimming
NO
Ballast Control
NO
DMX
or what does SIMPLY5 not do?
PC Control
NO
27
SIMPLY for Everyone
SIMPLY5 is a sustainable solution
28
Application Example
29
Application Story
School Application Example
  • SIMPLY5 Fixture Layout
  • 2RT5 28T5 MVOLT
  • Other comparison system layout
  • 2GT8 3 32 A12
  • LB 2 32 MVOLT
  • EJ 2 32 MVOLT

30
Application Story
School Application Example
  • Classroom, Conference Room
  • and Private Offices
  • - 39 areas with 178 fixtures
  • - Fixture Spacing 8 x 10 centers
  • Total Square Footage 12,989

31
Application Story
School Application Example
32
Application Story
School Application Example
  • Energy Saving with RT5 SIMPLY5
  • Layering SIMPLY5 technology allows for even
    greater overall energy savings

33
Application Story
School Application Example
  • Fixtures on 10 x 10 Centers
  • Use 20 less fixtures
  • Require 10 less connections
  • Save More Energy
  • RT5 Only - 48
  • RT5 w/ S5 Timeclock - 60
  • RT5 w/ S5 Timeclock and occupancy
    sensors/photocells 75

SIMPLY5 is 20 less than Occupancy Sensors
34
Questions?
35
Demo Case Demonstration
36
(No Transcript)
37
SIMPLY for Everyone
Simple to Comply
  • Meets automated control requirements
  • for ASHRAE, IECC, Title 24 and EPAct
  • Meets power density requirements
  • Incorporates time clock control, occupancy
  • sensing and daylight harvesting

38
SIMPLY for Everyone
Simple to Specify
  • Lays out similarly to ordinary manual
    switching
  • Involves no complicated wiring
  • Needs no completion of relay or dimmer
    schedules
  • Requires no occupancy sensor layouts

39
SIMPLY for Everyone
Simple to Install
  • Fast and error-free connections
  • No complex Class 2 wiring requirements
  • Special communication cables not required
  • No large control panels to install or panel
    schedules to update
  • Commissioning is not required to meet code

40
SIMPLY for Everyone
Simple to Expand
  • Plug and play components can be added at
  • any time
  • Easily reconfigured to accommodate changes
  • Scalable architecture from single rooms to
  • multiple buildings

41
SIMPLY for Everyone
Simple to Use
  • Intuitive user interface allows occupants to
    adjust
  • light
  • Seven dimming levels available
  • Adaptive schedules maximize energy savings
  • while minimizing the hassle

42
SIMPLY for Everyone
Simple to Maintain
  • Multi-step electronic ballasts with program-
  • start features maximize lamp life
  • Adaptive electronics stay calibrated
  • Commissioning is not necessary when adding
  • or replacing components
  • Adaptive scheduling accommodates
  • occupants usage automatically without
  • reprogramming

43
SIMPLY for Everyone
Summary of Benefits
  • Empowered components
  • Distributed intelligence
  • Plug play connectivity
  • Simple installation and maintenance
  • Greater occupancy flexibility
  • Energy savings and sustainable design made easy
  • Meets local and state energy codes

44
Product Folder Review
45
The SIMPLY5 Solution
Why does this new approach make more sense?
  • Intelligence distributed throughout the system
  • No special wiring requirements and plug-in
    connections allow quick and error-free
    installation
  • No complicated commissioning required to meet
    codes all thats needed is to set the time.
  • Advanced features can be configured quickly via
    wall stations Light Energy Manager with no
    knowledge of installation details
Write a Comment