Title: crystalens HD
1Crystalens HD
2Crystalens HDIntroduction
- Multipiece silicone posterior chamber IOL for the
treatment of cataracts - Built on the heritage of success of Crystalens
IOLs
3- Crystalens IOLs are the first and only
FDA-approved accommodative IOLs
4Crystalens HD Design Enhancement
- Slight increase in negative spherical aberration
over central 1.5 mm of optic helps improve
depth-of-focus - Designed to improve near VA without compromising
distance VA or contrast sensitivity
5AccommodationMechanism
Fincham. The Mechanism of Accommodation. Br J
Ophthalmol 1937
6AccommodationResearch Findings
- Key studies
- Cramer. Humans (1851)
- Glasser et al. Primates (circa 2004)
- Breen, Dell, Waltz et al. (circa 2005)
- Crystalens study (2006)
- Maximum accommodative power change is in the
center of the crystalline lens or Crystalens
- Power change
- Greater in the center
- Less in the periphery
- Generally greater than the change in SE
(refraction) - Aberration
- Increase in negative spherical aberration
- Increase in coma
7Accommodation Progress in Understanding
Anatomical diagram of accommodative
arching (1937)
Wavefront mapping of accommodative
arching (2006)
8Phakic Accommodation Early Presbyopic Adult
UCDVA 20/20 UCNVA J2
Power change 2.58 D Demand 3.00 D
Pupil size distance 4.20 Pupil size near 4.10
9Phakic Accommodation 11-Year-Old Subject
UCDVA 20/15 UCNVA J1
Power change 1.97 D Demand 2.50 D
Pupil size distance 6.7 Pupil size near 4.8
10Crystalens Accommodation Crystalens Vs Natural
Lens
Natural crystalline lens
Crystalens HD
crystalens
11Crystalens Accommodation3 Years Post-Surgery,
70-Year-Old Subject
UCDVA 20/15 UCIVA 20/20 UCNA J1
Power change 4.81 D Demand 2.50 D
Pupil size distance 3.8 Pupil size near 3.1
12Crystalens HD
Crystalens HD was designed to mimic the central
bulging of a young natural lens consistently
13Lens Comparison
14Crystalens HD50 Magnification
15Crystalens HD Vs Five-O 36 Magnification
Crystalens Five-O
Crystalens HD
16(No Transcript)
17Image Quality
18ONE Point of FocusSimulated Images
19IOL Quality of Vision
? Crystalens HD100 ? Crystalens AT-50SE ?
ReSTOR SN60D3 ? ReZoom ? ReSTOR SN6AD3
NB Resolution of the human eye is between 6 and
20 cycles/mm
20Distance Image Quality under Mesopic Conditions
21Depth of Focus
22Depth of Field
Crystalens HD
AT-45
Wavefront Error
P-V 0.72 RMS 0.57
P-V 0.51 RMS 0.36
Bench Test
Data from Ed Sarver
23Through Focus Study
5 mm pupil
3 mm pupil
Image Sharpness
Image Sharpness
Diopters
Diopters
243-mm Pupil
Crystalens HD
ReSTOR SA60D3
ReSTOR SN60D3
-1.0 D
-0.5 D
Plano
0.5 D
1.0 D
1.5 D
2.0 D
255-mm Pupil
Crystalens HD
ReSTOR SA60D3
ReSTOR SN60D3
-1.0 D
-0.5 D
Plano
0.5 D
1.0 D
1.5 D
2.0 D
26Crystalens HD Outcomes
27Crystalens HDEvidence of Effectiveness
- Objective
- To assess the effectiveness of the Crystalens HD
(HD-100) accommodating IOL in providing near,
intermediate, and distance vision - Design
- Eligible patients were screened preoperatively to
establish a baseline - Patients underwent small-incision cataract
surgery with phacoemulsification and a continuous
circular tear intact capsulorhexis and were
implanted with Crystalens HD-100 IOL
28Crystalens HDPlatform
- Clinical evaluation was performed on the AT-45
platform - The HD will be commercialized on the Five-O
platform
29InvestigatorsFDA Clinical Trial
30Crystalens HD TrialStudy Parameters
- Visual Acuity (VA)
- Uncorrected
- Near (40 cm), intermediate (80 cm), and distance
- Corrected
- Near with distance correction, with and without
the minimal reading and for the best-corrected
near VA - Intermediate with distance correction
- Distance best corrected
- Compared with Crystalens AT-45
- Contrast sensitivity
- Under mesopic conditions with and without glare
- Under photopic conditions without glare
- Compared with Crystalens AT-45 and Five-O
31HD-100 Uncorrected Distance VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
32HD-100 Uncorrected Intermediate VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
33HD-100 Uncorrected Near VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
34Crystalens HD Outcomes
- Comparison with Previous Generation Crystalens
IOLs
35AT-45, Five-O, and HD-100 Uncorrected Near VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
n60
Monocular
Subjects
36AT-45, Five-O, and HD-100 Distance-Corrected
Near VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
n60
Subjects
37Log Contrast SensitivityMesopic Illumination (3
cd/m2) Without Glare
Log contrast Sensitivity
Spatial Frequency
38Log Contrast Sensitivity Mesopic Illumination (3
cd/m2) With Glare (3 Lux)
Log contrast Sensitivity
Spatial Frequency
39Crystalens HD Outcomes
- Comparisons with Multifocal IOL Clinical Trial
Outcomes
40FDA Labeling Monocular Distance UCVA
41FDA Labeling Monocular Near UCVA
42FDA Labeling Monocular Intermediate UCVA
Intermediate VA not reported for Tecnis
MF 20/25 or better UCIVA not reported for ReSTOR
MF
43Mean Uncorrected Intermediate VA
20/20
20/25
20/32
20/40
Crystalens HD only tested at 80 cm
43
44Distance Contrast Sensitivity Mean Photopic
without Glare
Log Contrast Sensitivity
Spatial Frequency
44
45Distance Contrast Sensitivity Mean Mesopic
without Glare
Log Contrast Sensitivity
Spatial Frequency
45
46Distance Contrast Sensitivity Mean Mesopic with
Glare
Log Contrast Sensitivity
Spatial Frequency
46
47Postmarket Results with Crystalens HD
48- DataLink is an online registry hosted by
SurgiVision Consultants, Inc. that is available
to all Crystalens IOL users - Crystalens HD (HD) data have been added by new
and existing Crystalens IOL surgeons - Includes Crystalens and other presbyopia-correctin
g IOLs
49Results
- As of March 21, 2009
- Total of 41,538 eyes in the registry
- 4,992 are implanted with Crystalens HD
- This following data are based on Month 1 outcomes
50One Month Data Available
51Refractive PredictabilityMean 1 Standard
Deviation
0.61 D
0.62D
0.55 D
0.52 D
52UCVA Comparisons Binocular Distance UCVA
53UCVA Comparisons Binocular Intermediate UCVA
54UCVA Comparisons Binocular Near UCVA
55Recommendations
56Refractive Target
- The optimal postop refraction is plano to plus in
the distance eye, plano to minus in the near eye - IOL power selection anticipates change in
refraction with healing - A target of slight plus for the distance eye
- Pick the IOL with the Lowest Plus predicted
outcome - Will result in plano or near-plano outcome,
accounting for slight myopic change in most eyes
57Pre-Operative
- Pre-operative measurements critical to your
success Accurate IOL Calculation - Keratometry- Immersion and IOL Master
- Axial Length
- If in doubt or if any of the measurements is
questionable, take measurements again
58Manage Astigmatism
- Use outcome from first eye to help guide second
eye selection - Plan treatment to result in residual cylinder
amounts of 0.50 D - Plan refractive correction of preoperative
cylinder - Treat any postoperative cylinder, as needed
59IOL Calculation
- Use Holladay II formula
- If axial length is 22.0 mm
- Manufacturers ACD 5.55 mm
- If mean Ks are flatter than 42.00 D or steeper
than 47.00D, independent of axial length - For all post-refractive eyes
- Use SRK-T formula
- If axial length is gt22 mm
- A-constant 119.0
60Intra-Operative
- Watertight incisions a must
- Capsulorrhexis size 5.5-6.5 mm
- Right side up insertion of lens
- Hinge open side should be facing the anterior
part of the eye on implantation - Positioning the Crystalens HD
- Most surgeons place the haptic at the 1200 and
600 position at the equator inside the capsular
bag
61Insertion System
62Crystalsert Insertion System
- Easy, controlled, planar, one-handed lens
delivery - Inject through sub-3 mm incision
- Single use, disposable device
63Loading the Crystalsert
64Injector Pearls
- 2.8mm incision size
- DO NOT PUMP THE PLUNGER
- Wound entry at about 45 degrees
- Clear the slits
65Crystalens HDSummary
- First and only FDA-approved accommodating IOL
- Mimics natural focusing action of the eye
- Provides single focal point
- Modified optic increases focal range
- Provides improved near vision versus previous
generations, without compromise to intermediate
or distance vision - No compromise to contrast sensitivity
66Crystalens HD
Thank You