Crystalens HD
2
Crystalens HDIntroduction
  • Multipiece silicone posterior chamber IOL for the
    treatment of cataracts
  • Built on the heritage of success of Crystalens
    IOLs

3
  • Crystalens IOLs are the first and only
    FDA-approved accommodative IOLs

4
Crystalens HD Design Enhancement
  • Slight increase in negative spherical aberration
    over central 1.5 mm of optic helps improve
    depth-of-focus
  • Designed to improve near VA without compromising
    distance VA or contrast sensitivity

5
AccommodationMechanism
Fincham. The Mechanism of Accommodation. Br J
Ophthalmol 1937
6
AccommodationResearch Findings
  • Key studies
  • Cramer. Humans (1851)
  • Glasser et al. Primates (circa 2004)
  • Breen, Dell, Waltz et al. (circa 2005)
  • Crystalens study (2006)
  • Maximum accommodative power change is in the
    center of the crystalline lens or Crystalens
  • Power change
  • Greater in the center
  • Less in the periphery
  • Generally greater than the change in SE
    (refraction)
  • Aberration
  • Increase in negative spherical aberration
  • Increase in coma

7
Accommodation Progress in Understanding
Anatomical diagram of accommodative
arching (1937)
Wavefront mapping of accommodative
arching (2006)
8
Phakic Accommodation Early Presbyopic Adult
UCDVA 20/20 UCNVA J2
Power change 2.58 D Demand 3.00 D
Pupil size distance 4.20 Pupil size near 4.10
9
Phakic Accommodation 11-Year-Old Subject
UCDVA 20/15 UCNVA J1
Power change 1.97 D Demand 2.50 D
Pupil size distance 6.7 Pupil size near 4.8
10
Crystalens Accommodation Crystalens Vs Natural
Lens
Natural crystalline lens
Crystalens HD
crystalens
11
Crystalens Accommodation3 Years Post-Surgery,
70-Year-Old Subject
UCDVA 20/15 UCIVA 20/20 UCNA J1
Power change 4.81 D Demand 2.50 D
Pupil size distance 3.8 Pupil size near 3.1
12
Crystalens HD
Crystalens HD was designed to mimic the central
bulging of a young natural lens consistently
13
Lens Comparison
14
Crystalens HD50 Magnification
15
Crystalens HD Vs Five-O 36 Magnification
Crystalens Five-O
Crystalens HD
16
(No Transcript)
17
Image Quality
18
ONE Point of FocusSimulated Images
19
IOL Quality of Vision
? Crystalens HD100 ? Crystalens AT-50SE ?
ReSTOR SN60D3 ? ReZoom ? ReSTOR SN6AD3
NB Resolution of the human eye is between 6 and
20 cycles/mm
20
Distance Image Quality under Mesopic Conditions
21
Depth of Focus
22
Depth of Field
Crystalens HD
AT-45
Wavefront Error
P-V 0.72 RMS 0.57
P-V 0.51 RMS 0.36
Bench Test
Data from Ed Sarver
23
Through Focus Study
5 mm pupil
3 mm pupil
Image Sharpness
Image Sharpness
Diopters
Diopters
24
3-mm Pupil
Crystalens HD
ReSTOR SA60D3
ReSTOR SN60D3
-1.0 D
-0.5 D
Plano
0.5 D
1.0 D
1.5 D
2.0 D
25
5-mm Pupil
Crystalens HD
ReSTOR SA60D3
ReSTOR SN60D3
-1.0 D
-0.5 D
Plano
0.5 D
1.0 D
1.5 D
2.0 D
26
Crystalens HD Outcomes
27
Crystalens HDEvidence of Effectiveness
  • Objective
  • To assess the effectiveness of the Crystalens HD
    (HD-100) accommodating IOL in providing near,
    intermediate, and distance vision
  • Design
  • Eligible patients were screened preoperatively to
    establish a baseline
  • Patients underwent small-incision cataract
    surgery with phacoemulsification and a continuous
    circular tear intact capsulorhexis and were
    implanted with Crystalens HD-100 IOL

28
Crystalens HDPlatform
  • Clinical evaluation was performed on the AT-45
    platform
  • The HD will be commercialized on the Five-O
    platform

29
InvestigatorsFDA Clinical Trial
30
Crystalens HD TrialStudy Parameters
  • Visual Acuity (VA)
  • Uncorrected
  • Near (40 cm), intermediate (80 cm), and distance
  • Corrected
  • Near with distance correction, with and without
    the minimal reading and for the best-corrected
    near VA
  • Intermediate with distance correction
  • Distance best corrected
  • Compared with Crystalens AT-45
  • Contrast sensitivity
  • Under mesopic conditions with and without glare
  • Under photopic conditions without glare
  • Compared with Crystalens AT-45 and Five-O

31
HD-100 Uncorrected Distance VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
32
HD-100 Uncorrected Intermediate VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
33
HD-100 Uncorrected Near VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
34
Crystalens HD Outcomes
  • Comparison with Previous Generation Crystalens
    IOLs

35
AT-45, Five-O, and HD-100 Uncorrected Near VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
n60
Monocular
Subjects
36
AT-45, Five-O, and HD-100 Distance-Corrected
Near VA
Within 0.50 D of Intended Target Refraction
4-6 Months Postoperatively
Monocular
n60
Subjects
37
Log Contrast SensitivityMesopic Illumination (3
cd/m2) Without Glare
Log contrast Sensitivity
Spatial Frequency
38
Log Contrast Sensitivity Mesopic Illumination (3
cd/m2) With Glare (3 Lux)
Log contrast Sensitivity
Spatial Frequency
39
Crystalens HD Outcomes
  • Comparisons with Multifocal IOL Clinical Trial
    Outcomes

40
FDA Labeling Monocular Distance UCVA
41
FDA Labeling Monocular Near UCVA
42
FDA Labeling Monocular Intermediate UCVA
Intermediate VA not reported for Tecnis
MF 20/25 or better UCIVA not reported for ReSTOR
MF
43
Mean Uncorrected Intermediate VA
20/20
20/25
20/32
20/40
Crystalens HD only tested at 80 cm
43
44
Distance Contrast Sensitivity Mean Photopic
without Glare
Log Contrast Sensitivity
Spatial Frequency
44
45
Distance Contrast Sensitivity Mean Mesopic
without Glare
Log Contrast Sensitivity
Spatial Frequency
45
46
Distance Contrast Sensitivity Mean Mesopic with
Glare
Log Contrast Sensitivity
Spatial Frequency
46
47
Postmarket Results with Crystalens HD
  • DataLink Registry Data

48
  • DataLink is an online registry hosted by
    SurgiVision Consultants, Inc. that is available
    to all Crystalens IOL users
  • Crystalens HD (HD) data have been added by new
    and existing Crystalens IOL surgeons
  • Includes Crystalens and other presbyopia-correctin
    g IOLs

49
Results
  • As of March 21, 2009
  • Total of 41,538 eyes in the registry
  • 4,992 are implanted with Crystalens HD
  • This following data are based on Month 1 outcomes

50
One Month Data Available
51
Refractive PredictabilityMean 1 Standard
Deviation
0.61 D
0.62D
0.55 D
0.52 D
52
UCVA Comparisons Binocular Distance UCVA
53
UCVA Comparisons Binocular Intermediate UCVA
54
UCVA Comparisons Binocular Near UCVA
55
Recommendations
56
Refractive Target
  • The optimal postop refraction is plano to plus in
    the distance eye, plano to minus in the near eye
  • IOL power selection anticipates change in
    refraction with healing
  • A target of slight plus for the distance eye
  • Pick the IOL with the Lowest Plus predicted
    outcome
  • Will result in plano or near-plano outcome,
    accounting for slight myopic change in most eyes

57
Pre-Operative
  • Pre-operative measurements critical to your
    success Accurate IOL Calculation
  • Keratometry- Immersion and IOL Master
  • Axial Length
  • If in doubt or if any of the measurements is
    questionable, take measurements again

58
Manage Astigmatism
  • Use outcome from first eye to help guide second
    eye selection
  • Plan treatment to result in residual cylinder
    amounts of 0.50 D
  • Plan refractive correction of preoperative
    cylinder
  • Treat any postoperative cylinder, as needed

59
IOL Calculation
  • Use Holladay II formula
  • If axial length is 22.0 mm
  • Manufacturers ACD 5.55 mm
  • If mean Ks are flatter than 42.00 D or steeper
    than 47.00D, independent of axial length
  • For all post-refractive eyes
  • Use SRK-T formula
  • If axial length is gt22 mm
  • A-constant 119.0

60
Intra-Operative
  • Watertight incisions a must
  • Capsulorrhexis size 5.5-6.5 mm
  • Right side up insertion of lens
  • Hinge open side should be facing the anterior
    part of the eye on implantation
  • Positioning the Crystalens HD
  • Most surgeons place the haptic at the 1200 and
    600 position at the equator inside the capsular
    bag

61
Insertion System
62
Crystalsert Insertion System
  • Easy, controlled, planar, one-handed lens
    delivery
  • Inject through sub-3 mm incision
  • Single use, disposable device

63
Loading the Crystalsert
64
Injector Pearls
  • 2.8mm incision size
  • DO NOT PUMP THE PLUNGER
  • Wound entry at about 45 degrees
  • Clear the slits

65
Crystalens HDSummary
  • First and only FDA-approved accommodating IOL
  • Mimics natural focusing action of the eye
  • Provides single focal point
  • Modified optic increases focal range
  • Provides improved near vision versus previous
    generations, without compromise to intermediate
    or distance vision
  • No compromise to contrast sensitivity

66
Crystalens HD
Thank You
Write a Comment
User Comments (0)
About PowerShow.com