Title: Cisco Wiring Project First Baptist Church
1- Cisco Wiring Project First Baptist Church
Designed by Roy Harding
2History of First Baptist Church
- 1843 ? First Organized
- 1848 ? First church built on corner of North and
East Streets - Steady growth required a new building
3History of First Baptist Church
- 1890 ? New building dedicated with 225 members
- 1971 ? 17 acres of land dedicated on West
Maitland Lane - 1974 ? Final service in the N. E. St. building
4History of First Baptist Church
- 1974 ? May 5th 36,381sq.ft. building dedicated
cost 1.3 million accommodates 800 members - 1980 ? Mortgage burned
- 1991 ? Youth complex was dedicated
5Current Status of FBC
- 2000 ? 800 Members
- 4 Pastors
6Current Status of FBC
- 2 Services at 900 a.m. 1045 a.m.
- Live radio broadcast1100 a.m.- 1200 noon WBZY
1280
7First Baptist Churchs Vision
- Place of Hope Grow
- People Matter to God
- Personal Relationship with God
- Environment of Hope
- Growth Producing Relationships
8Projected Growth
- Proposed renovation in 2002
- Church facilities
- Youth building
- Hiring of Pastor of Young Adult Ministries
9Analysis and Assessment of Current and Projected
Resources and Needs
- 9 Personal computers
- Operating systems Windows 95 98
- 8 DeskJet printers
- 1 Shared laser printer
- 1 copier
- 8 Network cards
- Currently using sneakernet
10Identify Needs
- Projected growth in church staff
- Share data and resources
- Centralized data backup system
- Internet access
- Email
11Constraints of the Church
- Financial resources 1,000
- Computer skills
- Attitudes to networking
- Proposed renovations
12Walkthrough
- Check ceilings walls
- Check distances
13Network Design
- Ethernet IEEE 802.3 Cat 5 UTP Cable
14Estimate
- Data Comm Warehouse
- Estimate material needs
- Present estimate to Trustee Board
15Material Order YESCO
- 1 59484B24 24 Port Patch Panel 74.82
- 1 Box of 20 TSR1I6A 6ft. Raceway 102.60
- 10 410892IP 2 port surf. Box 11.69
- 15 41108RI5 C5 jacks 48.45
- 10 TSR1I25 elbo cover 7.30
- 20 TSR1I33 external cover 14.60
- 10 TSR1I14 splice cover 7.30
- 5 1000ft cat.5 24/4 blue cable 241.78
- 1 hpwwb6u18 hubbell wall mount bracket 139.00
- 1 16 port rack mount 10/100 HUB 165.00
- 6 14 ft. patch cord cat 5 19.60
- 3 7 ft patch cord cat 5 4.75
- 10 3 ft. patch cord cat 5 10.83
- Total 850.82
- Material Return
- 15 TSR1I6A raceway 76.95
- 4 410892Ip 2 port surf. Box 4.68
- 5 41108RI5 C5 jack 16.15
Material Order 850.82 Material Return
126.98 SubTotal 723.84 Proposed
Webramp 369.99 Total
1,093.83
16Wiring Closet
- Location of MDF
- MDF specifications
- EIA/TIA-569
- Central location 90 meters catchment area
- Secure location
- Walls Floors Doorway
- Lighting Ceiling
- Temp. 70 Humidity 30-50
- Power Outlet
- Mounting Bracket
- Cut sheet
-
172
6
3
5
4
1
1 Jan 154 6 Pastor Mike 169 2
Donna 129 7 Roberta 170 3 Copier 127 8 Lois
94 4 Pastor Scott149 9 Pastor Dave 198 5 Pastor
Dan 178 10 Robin 143
Catchment Area
MDF
Cut Sheet Catchment area
10
7
9
8
18Pulling Cable
- EIA/TIA-568B- Specifies horizontal cabling scheme
- Pulled 6 wires down main office hallway
- Pulled 1 wire to Robertas
- Pulled 3 wires down hallway to Pastor Daves
19Patch Panel Hub Jacks
EIA-TIA 568-B standards. We have learned that
horizontal cabling, as defined by EIA/TIA-568B,
is the networking media that connects the
telecommunications outlet to the horizontal
cross-connect.
20Cable Testing
- Fluke Cable Tester Map test Cable Distance
21Software Upgrade NIC Installation
- Clients Upgraded Donna Pastor Mike Roberta Lois
Pastor Scott ??
- Win95 to Win98
- NIC installation
- Software setup
- NIC Installation Software Setup
- 4 NICs installed
- Software setup
- Network Neighborhood
- MS network File Print sharing ID
name WorkGroup name
22Wiring Journal of FBC
Cable Run Length In Feet
1 Jan 154 6 Pastor Mike 169 2
Donna 129 7 Roberta 170 3 Copier 127 8 Lois
94 4 Pastor Scott149 9 Pastor Dave 198 5 Pastor
Dan 178 10 Robin 143
Work Group - Chruch
232
6
3
5
4
1
1 Jan 154 6 Pastor Mike 169 2
Donna 129 7 Roberta 170 3 Copier 127 8 Lois
94 4 Pastor Scott149 9 Pastor Dave 198 5 Pastor
Dan 178 10 Robin 143
Catchment Area
MDF
Journal Cable Runs Id.Clients
10
7
9
8
24