Title: Cot%20SURGICAL%20SUCTION
1Cot SURGICAL SUCTION
- Sep-T-Vac Collection systems
- Yankauers
- Connecting tubes
- Suction Catheters
- Devon
2Surgical SuctionObjectives
- Operating Room To remove biological fluids and
clean the operating field during and after
surgical procedures and after - Generic Wards To continue to drain and monitor
liquids after surgical procedure and generally to
collect biological fluids
3Surgical SuctionWhat you need
- Vacuum source
- Connecting tubes (from wall collection systems
and from collection systems to the cannula - Collection systems (Sep-T-Vac)
- Suction Cannulas (Yankauers)
4Surgical suctionOperating room
Sterile Area
Non Sterile Area
Suction source
Yankauer
Pre-cutted tube
Operating table
Bubble tube
Collection Chamber
5Sep-T-VacTyco Product Range
- Product range
- 100 Disposable 0,8 l/1,2 l/2.0 l/3,0 l
- Liners 1,2 l/2,0 l/ 3,0 l
6Sep-T-VacMain Features
- Collection chamber
- Airtight cap Connections for yankauers and
suction source - Filter
7Sep-T-Vac Collection chamber
8Sep-T-Vac Cap
9Sep-T-VacFilter
- Sep-T-Vac filter
- Gore Tex Hydrophobic shut-off filter. Gore Tex is
moisture sensitive and it automatically stops
aspiration when collected liquid is at the top of
the chamber. - It is not a mechanical system an it prevents also
micro-particles and aerosol leakages
10(No Transcript)
11Sep-T-Vac Overall Features and Benefits
12Sep-T-Vac 100 DisposableFeatures and Benefits
13Sep-T-Vac LinersFeatures and Benefits
14Sep-T-Vac Accessories
15YankauersTyco Product Range
- Semirigid Yankauers
- Rigid Yankauers
- Yankauers Poole
- Yankauers Select Trol
- Yankauer set
16Surgical suctionYankauers Product range
Yankauer
Select Trol
Rigid yankauers
Poole set
Flexible yankauer
17YankauersMain Features
- Tip different shapes and distal hole section to
better fit customers needs - Fine Accurate aspirations with low quantity of
fluids (mini-invasive surgical procedures. ie
neurosurgery and oftalmic) - Regular General surgery
- Large High suction volume (to use after washing
procedures and with high volume to drain)
18YankauersMain Features
- Extra Large to suction high volume of fluids,
blood clots, bony fragments in short time - Sump tip to avoid the bony fragments and organic
residuals suction (preferred in orthopaedic
surgery) - Bulbe tipit is used as dissector and retractor
instrument - Flat tipindicated for suctioning in difficult
manoeuvrability situations and to suction in
short places
19Semirigid YankauersFeatures and Benefits
20Rigid YankauersFeatures and Benefits
21Yankauer PooleFeatures and Benefits
22Select Trol YankauersFeatures and Benefits
23COMPETITOR ANALYSIS
24Connecting tubes Tyco Product Range
Argyle conn. tube
Sure Grip
25Connecting tubes with Sure gripFeatures and
Benefits
26Universal bubble tubing Features and Benefits
27COMPETITOR ANALYSIS
28Bronchial SuctioningAnathomy
29Bronchial SuctioningObjectives
- To suction mucus from the bronchi and trachea (to
guarantee the correct lung ventilation and blood
oxygenation vs nosocomial infections and
atelectasia)
30Bronchial SuctioningWhat you need
- Vacuum source
- Connecting tubes
- Suction catheters
- Mucus trap
31SuctioningType of..
- Naso-Tracheal suctioning
- Endo-Tracheal suctioning
- Tracheostomy suctioning
32SuctioningRisks
- Damage of nasal, oral, tracheal, pharinx and
bronchial tissue - Bleeding
- Infections
33Suction cathetersMain features
- Tip It is related to the efficiency in
aspiration (speed and suctioning capacity of
viscous mucus) and tissue damage - Connector to vaccum
- With Touch Trol or Funnel or Sure Grip
34Suction catheters
- Type of suction catheter systems
- Opened systems
- Through nose/mouth
- Through endotracheal tube
- Through tracheostomy
- Closed systems
- Prevention of pulmonary infections
35Suction catheters Opened systems
36Suction cathetersTyco Product Range
- Commodities products Touch Trol
- Scotsman
- Sure Grip
- High quality and exclusive products
- Aero-Flo
- Gentle Flo
37Suction cathetersOverall Features and Benefits
38Moulded Funnel Features and Benefits
39Aero FloFeatures and Benefits
40Aero JetFeatures and Benefits
Exclusive
41Suction Catheters Closed systems
42Prevent Nosocomial Infection
43Prevent Nosocomial Infections
- ? sources of infection
- endogene germs
- ?patien-own germs
- exogene germs
- ?direct contact (hands of staff)
- ?indirect contact (equipment, med. products,
air) - ? because of these reasons there are no hospitals
without nosocomial infections !
44Prevent Nosocomial Infections
- ? most important reasons for nosocomial
infections - spreading of resistent pathogenes
- increasing disposition of the patients
- increasing exposition to bacteria with burst of
the body defense - ignoring of the hygiene measures
- non correct use of the products
- rising average age of our patients
45Prevent Nosocomial InfectionsMain NI
- Airway infections (30)
- Urinary tract infections (30)
- Surgical wound infections (15)
- Blood infections (5)
- Gastrointestinal infections (5)
- Others (15)
chart of Italian Society on prevention of
Infections
46Prevent Nosocomial Infections
- prevention of nosocomial respiratory infections
- stationary treated patients / p.a. ca.
16.000.000 - nosocomial infections / p.a. ca. 1.000.000
- number of deadly nosocomial infections ca.
30.000 - 40.000 - number of road casualties ca. 12.500
- ? annually more people die of nosocomial
infections than on our roads!
chart of Prof. Klaus Dieter Zastrow (BGA Berlin)
47Prevent Nosocomial Infections
- Infections to the respiratory tree are the
- first for patient mortality with 47
- To prevent respiratory infections it is
- really important to correctly manage
- medical devises
48Prevent Nosocomial InfectionsCosts of NI
- UTI from 200 to 1,000 US
- Wound infection from 2,000 to 4,000 US
- Airway infection from 1,200 to 8,000 US
- Blood infections from 2,500 to 27,000 US
- Italian Society studies on Nosocomial Infection
- (European panel)
49Mucus trapsObjectives
- Objective
- to collect mucus for clinical analysis
Specimen Trap for broncoscopy use
De lee/Lukens for neonatal use
50Mucus trapOverall Features and Benefits
51Mucus TrapOverall Features and Benefits
52Surgical SuctionTargets
Intensive Care
Dept.
Surgical Depts
Pneumology
Customer
Nurse