Title: Signals from ISTP-001
1Signals from ISTP-001 April 11-13,
2005 Preliminary Assessment C Neumeyer
298 Shots Performed for ISTP and for Magnetics
Calibration
Hold Point
Hold Point
Final Shots were 50 and 100 daily test shots
3Voltage Probes
- Same as last run except 8 channels have AB
monitoring - Allows monitoring of out-of-plane loading
- Web page developed to archive probe vs. channel
assignments (instead of reliance on notebook
records)
4Fiber Optic Temperature, Strain, and Displacement
- Flags (inner, outer/top, bottom)
- 4 flags x 3 strain/flag 12 strain
- 4 flags x 1 temp/flag 4 temp
- Hub and Flag twist angle (top, bottom)
- 2 displacement
- Flag end ?Z ?? motion (top, bottom)
- 4 displacement
- Hub (top only)
- 1 displacement
New
Total 23 transducers
8 conditioner channels
FISO Technologies, Inc.
5Top Voltage Probe Cable Tray 8 f/o extension
cables
TF Joint Inst Rack
FISO
FISO
Max 8 signals at a time from Top or bottom
Joint Res Meas System
CAMAC
Bottom Voltage Probe Cable Tray 8 f/o
extension cables
6Joint Voltage for 4.5KG TF-Only and Combined 100
Field Shots
2004
2005
21L Meas
mV
7Joint Voltage for 4.5KG TF-Only and Combined 100
Field Shots
2004
2005
21L Meas
mV
8Flag Probe Temperature During TF-Only Shots - 2004
First Evidence of Liftoff at 4.5kG
degC
21U
9Flag Probe Temperature During TF-Only Shots - 2005
degC
21U
10Flag Probe Temperature During TF-Only Shots -
2004 5
2005
2004
degC
21U
11Strain During 4.5KG TF-Only, TFOH, and Combined
100 Field Shots
21L LHS
microS
21L RHS
microS
12Strain During 4.5KG TF-Only, TFOH, and Combined
100 Field Shots
microS
21L LHS
21L RHS
microS
13Flag End Displacement During TF-Only Shots
4 mils 2005 gt 20 mils 2004
21L Vert
mil
21L Horiz
mil
14Flag End Displacement During 4.5KG TF-Only
Combined 100 Field Shots
OH
PF2
21L Vert
mil
21L Horiz
mil
15Toroidal Twist Measured by Flag End w.r.t.
Umbrella TF-Only 4.5kG TF OH, TF PF2
OH
PF2
21U
deg
21L
deg
16In-Plane Moment to Joint from PSRTC
115134
17Out-Of-Plane Moment to Joint from PSRTC
115134
18Peak Pressure at Joint from PSRTC
115134
19Hub/Box Shear Load from PSRTC
115134
20Voltage Drop Measurements vs. Model
21Voltage Drop Measurements vs. Model
22Benchmarking Procedure
- Fit Structural Coefficients to Measurements
- Identify Worst Case Joint
- Re-Run Engineering models
- Re-Assess 6kG Performance