Title: HYDRAULICS_5
1HYDRAULICS_5
- Design of Irrigation Systems
- by
- László Ormos
2DESIGN OF MANIFOLD
- The manifold is a pipe with multiple outlets to
the inlets of - lateral pipes. The size of plot, the flow rate
and the number - of shifts in a complete irrigation cycle should
be taken into - consideration.
- An orchard is designed for irrigation with a
solid set system. - The manifold is laid in the center of the field.
The whole plot - is irrigated simultaneously.
- The flow rate of selected sprinklers is
qs0.11m3/h at a - pressure hs2bars. The space between the
sprinklers along - the laterals is es6m. Space between laterals is
eL8m. - What are the diameters of pipes if the local head
loss in the - manifold and laterals is 10?
3DESIGN OF MANIFOLD
- The topography of field is the following
4DESIGN OF MANIFOLD
- Design of lateral
- The maximum allowable pressure head variation is
- The number of sprinklers on every laterals is as
follows - The length of lateral is
- 4. The total outlet of a lateral is
5DESIGN OF MANIFOLD
- For 16mm PE lateral pipe
- The hydraulic gradient when Q0.88m3/h and
J1622 - 6. The head loss in the lateral pipe (including
10 local head loss) and coefficient F60.38, is - Since hfgt?h the pipe diameter has to be
increased. - The hydraulic gradient if diameter is 20mm of PE
which has - J206.5 by Q0.88m3/h. is
6DESIGN OF MANIFOLD
- The head loss in the lateral pipe (including 10
local head loss) and coefficient F80.38, is - Since hflt?h the pipe diameter is good.
- 9. The inlet pressure in the lateral is
- 10. The water pressure by the last sprinkler on
the lateral is
7DESIGN OF MANIFOLD
- Design of manifold
- 11. The number of laterals is as follows
- 12. The length of manifold is
- 13. The total flow rate is as follows
8DESIGN OF MANIFOLD
- For 63mm PE manifold pipe
- 14. The hydraulic gradient when Q21.12m3/h and
J637.2 - 15. The head loss in the manifold (including 10
local head loss) and coefficient F240.371, is - 16. The pressure by the manifold inlet is
- 17. The pressure by the inlet of last lateral is
9DESIGN OF MANIFOLD
- 18. The minimum pressure in the entire system at
the last sprinkler on the last lateral is as
follows - 19. The pressure difference between the first and
last sprinkler is -
- Since the pressure difference ?hf-l is lower
than the allowable pressure head variation ?hmax,
the system is good.
10References
Azenkot, A.(1998)Design Irrigation System.
Ministry of Agricul- ture Extension Service
(Irrigation Field service), MASHAV Israel Dr.
Avidan, A.(1995)Soil-Water-Plant Relationship.
Ministry of Agriculture Extension Service
(Irrigation Field service), CINADCO, Ministry of
Foreign Affairs, MASHAV, Israel Sapir, E.-Dr. E.
Yagev (1995)Drip Irrigation. Ministry of
Agricul- ture and Rural Development, CINADCO,
Ministry of Foreign Affairs, MASHAV,
Israel Sapir, E.-Dr. E. Yagev (2001)Sprinkler
Irrigation. Ministry of - culture and Rural
Development, CINADCO,Ministry of Foreign
Affairs, MASHAV, Israel Eng. Nathan, R.
(2002)Fertilization Combined with Irrigation
(Fertigation). Ministry of Agriculture and Rural
Development, CINADCO,Ministry of Foreign Affairs,
MASHAV, Israel