HYDRAULICS_5
  • Design of Irrigation Systems
  • by
  • László Ormos

2
DESIGN OF MANIFOLD
  • The manifold is a pipe with multiple outlets to
    the inlets of
  • lateral pipes. The size of plot, the flow rate
    and the number
  • of shifts in a complete irrigation cycle should
    be taken into
  • consideration.
  • An orchard is designed for irrigation with a
    solid set system.
  • The manifold is laid in the center of the field.
    The whole plot
  • is irrigated simultaneously.
  • The flow rate of selected sprinklers is
    qs0.11m3/h at a
  • pressure hs2bars. The space between the
    sprinklers along
  • the laterals is es6m. Space between laterals is
    eL8m.
  • What are the diameters of pipes if the local head
    loss in the
  • manifold and laterals is 10?

3
DESIGN OF MANIFOLD
  • The topography of field is the following

4
DESIGN OF MANIFOLD
  • Design of lateral
  • The maximum allowable pressure head variation is
  • The number of sprinklers on every laterals is as
    follows
  • The length of lateral is
  • 4. The total outlet of a lateral is

5
DESIGN OF MANIFOLD
  • For 16mm PE lateral pipe
  • The hydraulic gradient when Q0.88m3/h and
    J1622
  • 6. The head loss in the lateral pipe (including
    10 local head loss) and coefficient F60.38, is
  • Since hfgt?h the pipe diameter has to be
    increased.
  • The hydraulic gradient if diameter is 20mm of PE
    which has
  • J206.5 by Q0.88m3/h. is

6
DESIGN OF MANIFOLD
  • The head loss in the lateral pipe (including 10
    local head loss) and coefficient F80.38, is
  • Since hflt?h the pipe diameter is good.
  • 9. The inlet pressure in the lateral is
  • 10. The water pressure by the last sprinkler on
    the lateral is

7
DESIGN OF MANIFOLD
  • Design of manifold
  • 11. The number of laterals is as follows
  • 12. The length of manifold is
  • 13. The total flow rate is as follows

8
DESIGN OF MANIFOLD
  • For 63mm PE manifold pipe
  • 14. The hydraulic gradient when Q21.12m3/h and
    J637.2
  • 15. The head loss in the manifold (including 10
    local head loss) and coefficient F240.371, is
  • 16. The pressure by the manifold inlet is
  • 17. The pressure by the inlet of last lateral is

9
DESIGN OF MANIFOLD
  • 18. The minimum pressure in the entire system at
    the last sprinkler on the last lateral is as
    follows
  • 19. The pressure difference between the first and
    last sprinkler is
  • Since the pressure difference ?hf-l is lower
    than the allowable pressure head variation ?hmax,
    the system is good.

10
References
Azenkot, A.(1998)Design Irrigation System.
Ministry of Agricul- ture Extension Service
(Irrigation Field service), MASHAV Israel Dr.
Avidan, A.(1995)Soil-Water-Plant Relationship.
Ministry of Agriculture Extension Service
(Irrigation Field service), CINADCO, Ministry of
Foreign Affairs, MASHAV, Israel Sapir, E.-Dr. E.
Yagev (1995)Drip Irrigation. Ministry of
Agricul- ture and Rural Development, CINADCO,
Ministry of Foreign Affairs, MASHAV,
Israel Sapir, E.-Dr. E. Yagev (2001)Sprinkler
Irrigation. Ministry of - culture and Rural
Development, CINADCO,Ministry of Foreign
Affairs, MASHAV, Israel Eng. Nathan, R.
(2002)Fertilization Combined with Irrigation
(Fertigation). Ministry of Agriculture and Rural
Development, CINADCO,Ministry of Foreign Affairs,
MASHAV, Israel
Write a Comment