Title: Trigger detectors: ageing test at GIF


1
  • Trigger detectors ageing test at GIF

Francesca Poggio Università degli Studi di
Torino I.N.F.N. sezione di Torino
2
ageing requirements (I)
max luminosity (cm-2 s-1)
integrated hits (106/cm2)
max hit rate (Hz/cm2)
months
collision system
heavy-ion program
1027
18
3
6
Pb-Pb
0.6x1029
48
24
2
Ar-Ar
1.1x1029
30
15
2
d-Pb
integrated hits in the most irradiated zone of
the most irradiated RPCs is 100 Mhit/cm2, 10
years
3
ageing requirements (II)
very different requirements for Pb-Pb wrt p-p.
Pb-Pb
d-Pb
p-p
small Cluster size good position resolution
Rate capability Detector lifetime
Ar-Ar
2 RD lines to fullfill the different requirement
both operating modes work with the same FE
electronic
4
outline
  • ageing test in streamer mode
  • RPC1 (full size g 70x210 cm2), results
  • efficiency measurement after ageing (cosmic rays)
  • ageing test in avalanche mode
  • small prototype 1
  • results
  • efficiency measurement after ageing (m beam)
  • small prototype 23
  • efficiency measurement before ageing (m beam)
  • ongoing ageing test

5
experimental layout at GIF (side view)
g monitor the efficiency of the detection for
cosmic ray under ?-induced counting rate

NOTE effective voltage correction HVeff
HV(p0/p)(T/T0) p0970 mbar, T0
20C current, rate and efficiency continuously
monitored with source on periodical
data-taking with source off dark current rate
current rate in absence of irradiation
6
ageing in streamer mode (50.5 Ar, 41.3 C4H10,
7.2 C2H2F4, 1 SF6)
7
RPC1 ageing results
see G. Travaglia talk Dimuon Meeting 2004,
Berg-en-Dal A. Musso talk June 1
first ageing test of a full size RPC (RPC1)
differentiated custom shielding to recreate
ALICE-like conditions of irradiation 6-60
Hz/cm2
after 100 Mhit/cm2 (corresponding to 50 mC/cm2)
  • dark current 13 mA
  • dark rate lt0.4 Hz/cm2
  • slight efficiency loss with 60 Hz/cm2
    irradiation due to resistivity increase
  • efficiency without irradiation (1 Hz/cm2) stable
    at 95
  • rate condition similar to the Pb-Pb operation
  • (max 3 Hz/cm2)

RPC1 works satisfactorily up to about 100
Mhit/cm2 fulfilling the requirement for the 10
year heavy-ion program
8
RPC1 efficiency measurement
RPC1 tested in the bench test for final RPCs
see M. Gagliardi talk June 6 efficiency for
cosmic rays detection has been measured over the
whole surface of the RPC with 20x20 cm2 cells
(cosmic ray tracked with 2 RPCs)
9
RPC1 efficiency radiography
see M. Gagliardi talk June 6
efficiency map at HV8300 V (working point) in
the most irradiated area
uniform and high efficiency (94), after 100
Mhits/cm2
10
ageing in avalanche mode(88 C2H2F4, 10 C4H10,
2 SF6)
11
small prototype 1 ageing results
see G. Travaglia talk Dimuon Meeting 2004,
Berg-en-Dal A. Musso talk June 1
  • after 225 Mhit/cm2 (34 mC/cm2)
  • dark current 1 mA and dark rate lt1 Hz/cm2
  • no efficiency loss without and with g
    irradiation (120 Hz/cm2)
  • efficiency stable at 94
  • problem after a first period (100 Mhit/cm2),
    from time to time at high rates (120 Hz/cm2), we
    observe
  • a fast increase of the current that gives
    instability
  • after HV off the RPC recovers a normal behavior
  • (high efficiency, low dark current and low dark
    rate)
  • NOTE g gas mixture 88 C2H2F4, 10 C4H10 and 2
    SF6
  • working point HV10900 V

12
beam test, setup
after the ageing test efficiency plateau
measurement for the detection of muons (m beam
from SPS-X5) scanning the whole surface of the RPC
13
small prototype 1 efficiency map
  • in all position the plateau reaches 0.95-0.97 of
    efficiency
  • the mean efficiency at HV10900 V (working point)
    is 0.95?0.001

low efficiency due to geometrical problems
14
small prototype 1 instability problem (I)
  • hp local discharge g the temperature in
    correspondence of the discharge point should
    increase appreciably
  • RPC without external
  • mechanics, with the
  • ground side fully covered
  • by thermosensitive adhesives

15
small prototype 1 instability problem (II)
mean T ?25 C over the whole surface (measured
with an IR thermometer)
RPC
16
  • the instability is given by a local discharge
  • the current trend during the instability seems to
    have a strict correlation with the high rates and
    also with the high voltage
  • NOTE g gas mixture 88 C2H2F4, 10 C4H10 and 2
    SF6
  • working point HV10900 V
  • we try to decrease the SF6 percentage to lower
    the working point
  • beam test to check the performances of RPCs with
    the gas mixture 90 C2H2F4, 10 C4H10 0.3
    SF6
  • working HV10100 V
  • performances no significant differences wrt 2
    SF6 gas mixture
  • tested 2 small prototypes

17
small prototypes 23 efficiency plateaux
small prototype 2
small prototype 3
  • in all position the plateau reaches 0.95-0.96 of
    efficiency
  • the mean efficiency at HV10100 V (working point)
    is 0.94?0.01
  • in all position the plateau reaches 0.95 of
    efficiency
  • the mean efficiency at HV10100 V (working point)
    is 0.94?0.01

18
small prototype 2 efficiency map
  • small
  • prototype 2

19
current vs int.hits small prototype 2
  • after 170 Mhit/cm2 (corresponding to 25.5
    mC/cm2)
  • dark current 6 mA
  • dark rate lt4 Hz/cm2

20
efficiency vs int.hits small prototype 2
  • after 170 Mhit/cm2 no efficiency loss, both with
    and without irradiation,
  • (HV 10050 V, effective voltage)

21
current vs int.hits small prototype 3
  • after 145 Mhit/cm2 (corresponding to 22 mC/cm2)
  • dark current 1-2 mA
  • dark rate lt1 Hz/cm2

22
efficiency vs int.hits small prototype 3
  • after 145 Mhit/cm2 no efficiency loss, both with
    and without irradiation
  • (HV 10010 V, effective voltage)

23
ageing in avalanche mode conclusions
  • small prototype 2 g after 170 Mhit/cm2
  • dark current 6 mA and dark rate lt4 Hz/cm2
  • no efficiency loss without and with g
    irradiation (100 Hz/cm2)
  • efficiency stable at 93-95
  • small prototype 3 g after 145 Mhit/cm2
  • dark current 1-2 mA and dark rate lt1 Hz/cm2
  • no efficiency loss without and with g
    irradiation (80 Hz/cm2)
  • efficiency stable at 93-95
  • the 2 prototypes work satisfactorily up to about
    145-170 Mhit/cm2
  • fulfilling the requirement
  • for 1.5 years of the p-p program for the most
    irradiated RPC
  • for 8 years of the p-p program for other RPCs
  • the test is going on

24
(No Transcript)
25
the ageing problem
  • the RD program to understand the RPCs ageing
    problems was focused on two aspects
  • effects due to flowing the RPCs with dry gas
  • g increase of bakelite resistivity
  • effects due to long-term operation of the
    detector in condition of high counting rates
  • g increase of bakelite resistivity and a surface
    damaging due to the streamer discharge

ageing proportional to integrated current per
surface unit (mC/cm2), i.e. to the integrated
hits per surface unit (Mhit/cm2) g increase of
the current drawn by the detector, a (minor)
increase of the single rate and a possible
efficiency decrease.
26
beam test small prototype 2
  • in all position the plateau reaches 0.95-0.96 of
    efficiency
  • the mean efficiency at HV10100 V (working point)
    is 0.94?0.01

27
beam test small prototype 3
  • in all position the plateau reaches 0.95 of
    efficiency
  • the mean efficiency at HV10100 V (working point)
    is 0.94?0.01

low efficiency due to geometrical problems