1
Calorimeter Parameters and Choices
  • Peter Nemethy
  • MECO Collaboration Meeting
  • Irvine - February 6-7, 2005

2
Present Configuration (new) REF DESIGN
  • 135cm LONG (down fr.150cm)
  • LEAD TUNGSTATE
  • At Temp 24deg C
  • 4 VANES of
  • 8 x 36 288 crystals
  • Total 1152 CRYSTALS
  • PWO crystal size
  • 3.75 x 3.75 x 12 cm3 13.5 RL
  • 2 APD/Crystal 13 x 13 mm2
  • Preamps at Detector
  • Shaper Amps outside.

3

PRESENT COST (k) CONTING () COST w CONT
CRYSTALS 1,215 26 1,530
APDs 1,800 32 2,376
PREAMP SHAPER SYST 288 20 345
POWER SUPPLY 480 20 576
CABLES w CONN 211 20 253
CALIB MON 55 25 69
MECH HOUSING 80 20 96
COOLING 40 20 48
TOTAL 4,168 27 5,292 (102)
4
PARAMETERS and CHOICES
  • LENGTH in Z (Scales ALL , exc. Mech. and
    cooling)?
  • gt ACCEPTANCE, EDGE EFFECTS.
  • CALORIMETER DEPTH (Scales XTAL Volume )?
  • gt ACCEPTANCE, RESOL, EDGE EFFECTS,
    PUNCHTHRU
  • HV POWER SUPPLY GANGING (scales HV )?
  • CRYSTAL Transverse Dimension(?) used
  • APD choice ?
  • 2 APD / Crystal to 1 (?) N.

5
ACCEPANCE vs CAL LENGTH
  • For 2 different
    Crystal depths

6
(No Transcript)
7
COST (w. CONT) vs ACCEPTANCE
  • Previous 150cm -gt 135cm Lose 2 Acceptance
  • 12 cm deep, 135cm -gt 120cm
  • LOSE 3 ACCEPTANCEsave 572K
  • 12 cm deep, 135cm -gt 112.5cm
  • LOSE 8 ACCEPTANCEsave 858K
  • 12 cm deep, 135cm -gt 105cm
  • LOSE 13 ACCEPTANCEsave 1144K
  • 10 cm deep, 135cm -gt 120cm
  • LOSE 7 ACCEPANCEsave 799K

8
Calorimeter Depth 12cm to 10cm
  • Save 225K. Edge, Punchthru and APD Nuclear
    Counter worse.
  • Ratio of FWHH(10cm)/FWHH(12cm) 5.6MeV / 3.1MeV
    1.8
  • Punchthru and Nuclear Counter Effect needs
    detailed sim.

9
(more) CHOICES
  • GANGING HV 2 APDs per CHANNEL. save 240K
  • Hardship and convenience
  • gain balancing harder Level-0 trigger?
  • 5V gt 20 Gain Change (at 1700V)
  • CRYSTAL TRANSVERSE SIZE CHANGE
  • Scaled already (3.75cm -gt 3.0cm) Channels
    scaled by 1.5
  • Matches manufacturing capability and Moliere
    radius 2cm
  • Light Collection Loss under study.

10
(no more) CHOICES
  • APD CHOICE and smaller AREA DEGRADE S/N and
    resolution.
  • Complicated, studies and info needed, if
  • vs area scaling? 3 sources. need budgetary
    quotes.
  • Physics gtresolution now est. 7.9
    (5.6) trigger rate?
  • Elec noise scales with light coll,
    photostatistics w. sqrt of.
  • Light Collection scales w. area (or somewhat
    better),
  • Measuring at NYU now.
  • Detector Capacitance varies widely, not area
    scaling
  • ex. Hamamatsu 1x1cm 300puff -- RMD
    1.3x1.3cm 150puff.
  • 2 APD/ XTAL to 1 ? DONT! Of course big save
    900K.
  • But lose control of APD nuclear counter
    effect (NCE).
  • No trustable reconstructed energy (infinite
    tail)
  • Increased trigger rate, NCE probab/event low
  • but base is all gt50MeV DIO showers, much
    higher rate.
  • Needs detailed MC study

11
CONCLUSIONS for DISCUSSION
  • SHORTER CALORIMETER yes. and physics scaling
  • understood. 120cm for sure, 112.5cm maybe,
    105cm hurts.
  • Depth Change 12cm to 10cm, not as favorable as
    shorter cal.
  • HV ganging doable though not convenient.
  • APD choices prefer not to degrade. No offer on
    BLing timescale.
  • 1 APD/CRYSTAL dont.