CDC ENTERPRISES, INC' TRAINING - PowerPoint PPT Presentation

1 / 49
About This Presentation
Title:

CDC ENTERPRISES, INC' TRAINING

Description:

CDC ENTERPRISES, INC' TRAINING – PowerPoint PPT presentation

Number of Views:52
Avg rating:3.0/5.0
Slides: 50
Provided by: antonio75
Category:

less

Transcript and Presenter's Notes

Title: CDC ENTERPRISES, INC' TRAINING


1
CDC ENTERPRISES, INC. TRAINING
AKDUCT INSTALLATION TRAINING
Complete Line of PE Air Distribution Ductwork
AKDUCT
2
CDCEI and NATE
Separate Training Exam
CDC Enterprises
AIR DISTRIBUTION Certification
AIT
CDCEIT Class A,M,I
4 Credit Awarded by NATE for Completion
AIT Program is a subset of the NATE Air
Distribution Certification
AKDUCT INSTALLATION TECHNICIAN (AIT)
AKDUCT INSTALLATION TRAINING
3
CDCEI TRAINING (CDCEIT)
  • CDC-AIT has 2 Training Courses
  • Associate AAIT
  • Product and Installation Overview
  • Lecture with Hands-on Exercise (Depended on
    facility)
  • NATE 4 Credits
  • Four hours of training
  • On-Line PRE-EXAM
  • Masters MAIT
  • Take Off, Quote, Materials List, Winning Bids
  • Two Hours Lecture Only

4
Training Package
  • Training Workbook
  • AKDUCT PRODUCT MANUAL
  • DVD/CD
  • AKDUCT PRODUCT MANUAL
  • Class Presentation Slides
  • Job Sites Slide Show and Videos
  • Hands-on Training (Depended on facility)
  • Cutting and attaching saddle, pipe, end caps,
  • Applying MAXSEAL, AK AIRTITE Sealants

5
Training Objectives
  • AKDUCT Products and Identify Fittings
  • Identify planning and placement for piping and
    fittings
  • Understand Pipe and Plenum Depth
  • Understanding clamping and gasket connections
  • Proper cutting techniques for saddle and pipe
  • Apply caulking techniques
  • Understand Leveling techniques
  • Understanding Pressure Testing

6
What is AKDUCT?
  • Created for underground air duct applications
  • Air tight above 1.5 water column pressure
  • Water tight, applications for Below Flood
    Elevation
  • Mold and mildew resistant, Close Cell
    Polyethylene
  • Certified ICC PMG 1023
  • Environmentally Friendly Recyclable, non-toxic
  • Light weight
  • Self Insulted tested to out perform PVC wrapped
    with R10
  • Easy to assemble
  • Easy to cut
  • Affordable
  • Modular
  • Durable
  • Available in standard sizes 3 - 20

7
Manufacturing Process
Once this is done the mold is removed from the
oven and allowed to cool for a period of time
The finished product is then removed from the
mold, clean, labeled and boxed
8
Injection Molding
9
Session 1 QUICK OVERVIEW
  • Identify Fittings
  • Identify planning and placement for piping and
    fittings
  • Understand Rough-in process

10
IDENTIFY AKDUCT FITTINGS
6 8 10 12 14 16 18 20
10 Pipe
Tee
Tee Reducer
45/ 90 Elbow
Saddle w/ 4x 12 Boot
Offset Saddle w/ 4x12 Boot
Saddle Reducer
Reducer
10 Inline Boot 4x 12
Plenum
Plenum Adapter
6 90 Boot 4x 12
6 Footer Boot 3x 14
End Cap
11
Five Register Sizes
  • 4x12 Center Saddle 6, 8, 10
  • 4x12 Offset Saddle 10,12
  • 4x12 90 Boot 6, 8
  • 4x24 Offset Saddle (fits 10, 12 pipe)
  • 6x24 Linear Diffuser
  • 6x36 Linear Diffuser
  • 6x48 Linear Diffuser
  • Every Linear Diffuser will need
  • Linear Diffuser Adapter
  • Side Saddle
  • Plenum Adapter
  • Two Clamps and Gaskets
  • Piece of Pipe to connect

12
LINEAR DIFFUSERS
  • Three Industry Standard Sized Linear Diffusers
  • 24x6
  • 36x6
  • 48x6

13
Linear Diffuser Adapter Connection
14
Linear Diffuser Adapter Connection
1
3
Flip right-side up
2
Pipe (duct) hole
6 to 14 hole (optional Plenum adapter)
15
Two Linear Diffuser Adapters
16
PLENUM, BOOT, SADDLE
  • Sealed Plenum Box
  • Sealed 4x12 90 Boot
  • Sealed 4x12 Center and Offset Saddles

17
SEALANTS
  • Quick intro I will talk more about this later
  • Sealing products
  • MAXSEAL gasket material
  • Tested to withstand 42 of water column pressure
    before leaking
  • AIRTITE SEALANT
  • Caulk for Saddle Plenum Adapter \
  • Tested to withstand 42 of water column pressure
    before leaking

18
MAXSEAL
  • Zero VOC
  • Instant tack
  • UV Resistant
  • BUTYL Rubber Base
  • Forms to irregular surfaces
  • Non-staining
  • Solids 100
  • Service Temperature -35F to 250F0
  • Application Temperature 35F to 110F
  • After bonding time a water tight seal
  • A full bond in 24 hrs
  • Shelf Life is 12 Months
  • Peel Strength 15 pounds per linear inch.
  • Water Resistance Excellent
  • U.S.D.A. Acceptability Product meets the U.S.D.A.
    requirements for the use in
  • meat and poultry processing areas under U.S.D.A.
    inspection.
  • F.D.A. Acceptability Meets 21 CRF175.105
  • requirements
  • ASTM-E84 Flame Spread Index 5 and Smoke
    Developed Index 5

19
Putting the System TogetherMAXSEAL Clamps and
Gaskets
  • One Clamp and Gasket per
  • Plenum Adapter
  • End Cap
  • 90º 4x12 Boot
  • 8 Section of Pipe
  • Two Clamps and Gaskets per
  • 90º Elbow
  • Reducer (one per size, larger and smaller)
  • Three Clamps and Gaskets per
  • Tee
  • Wye
  • There is no need to caulk the overlap of MAXSEAL
    gasket material.

20
AIRTITE SEALANT
  • There are 6 fittings in the AKDUCT system that
    require caulk to be connected
  • Plenum Adapter
  • Between 15 (6) and 7 (18) per tube
  • Reducing Side Saddle
  • About 5 per tube
  • 4x12 Center and Offset saddles
  • About 5 per tube
  • 4x24 Offset Saddle
  • About 3 per tube
  • Linear Diffusers
  • About 3 per tube
  • Boot Extensions
  • About 5 per tube

21
Reducers in the AKDUCT System
Four Types of Reducers, Each of these Reducers
can be cut in-between the lines
Concentric Reducer
Tee Reducer
12x 10x 8x 6 / 16x 14 x12 10
8 x 8 x 8 x 6
Saddle Reducer
Eccentric Reducer
18 x16 x 14 x 12
10 8 x 6 12 x 10 14 x 12 16 x 14 18
x 16 NOTE Fits on all pipe
22
Break for 15 minutes
QA starts at 500
23
Session 2
  • Plenum and Pipe Installation
  • Setting Plenum Depth
  • Plenum Size
  • Plenum adapter placement
  • Trench depth
  • Plenum Adapter
  • Clamp and Gasket
  • Pressure Testing

24
Plenum System
25
Placement of Plenum
SIZES - 20wx24lx36h / 25wx30lx48h
  • Subtract 12 from the height of either plenum as
    that portion will be above finished floor. (8
    above finished floor and 4 in SLAB)
  • Dig the hole, depending on which size plenum
    width, length, and height -12 deep
  • Set initial piece of pipe in the pre-dug trench
    and butt up to plenum
  • Mark the top and bottom of the pipe on the
    workable area of the plenum
  • Remove plenum from 20x24x24 or 25x30x36
    hole and use the plenum adapter to complete the
    outline of the pipe on the face of the plenum.

26
Installation of Plenum, Steps 6-8
25wx30lx48h
20wx24lx36h
  • Cut out marked outline
  • Attach plenum adapter per installation guidelines
  • Place plenum back in trench

27
Components
  • Pipe trench depth
  • Plenum and Pipe depth details
  • Solving for pipe size and trench depth

28
Pipe Depth
29
Installing Plenum Adapter
  • Once the plenum hole is dug along with the trench
    for the system set your plenum in the hole
    butting directly up to your initial run trench
  • Place a foam block in trench about an inch away
    from the plenum
  • Place your plenum adaptor flange pushed snuggly
    against the plenum and the throat resting on the
    foam block
  • Set plenum w/ attached adaptor back in trench,
    level, and youre ready for your first 8 piece
    of pipe

30
Plenum Depth
Plenum Depth PD
Plenum - 12 PD
Above floor is 8
SLAB 4
At lease 2 of fill below slab
Plenum
Clamp Gasket
Pipe Trench Depth
PD
example If Plenum Adapter is 10, then 2
10 2 14 (Pipe Trench Depth)
Foam Block Plenum Adapter (OD) Fill Pipe
Trench Depth
31
Setting Pipe Depth
PD Plenum Depth
Pipe Size
PLENUM
18 16 14 12 10 8 6
24
36
36
48
22 20 18 16
14 12 10
Pipe Trench Depth PD
32
Step 5 Attaching Air Test
  • Put end cap on end of pipe that was cut 1
  • Attach steel plate to opposite end with AAS
  • Attach valve
  • Apply pressure to system via hand pump or
    compressor
  • Attach manometer and open valve
  • Observe

33
PRESSURE TESTING
  • Overview of static pressure measurements
  • Inclined manometer
  • Diaphragm type differential pressure gauge
  • U-tube manometer
  • Electronic manometer / pressure measurement
  • Gauge / meter calibration
  • Absolute vs. Gauge Pressure
  • Static pressure
  • Air pressure measurement terminology
  • Velocity pressure
  • Total pressure

34
Break for 15 minutes
QA starts at 500
35
Session 3 - INSTALLATION
  • AKDUCT and Installation techniques
  • VIDEO
  • AIRTITE MAXSEAL
  • JOB SITES
  • CASE STUDIES
  • SLIDE SHOW Link here
  • INDUSTRY STANDARDS

36
13 Minutes
Click above or here to start
37
Weather conditions for application.
  • AKDUCT AIRTITE SEALANT
  • Apply above 40F
  • Service Temperature -40F to 250F
  • Service life over 100 years
  • Low VOC 187 gt LEED points
  • SPEC SHEET
  • MAXSEAL
  • Apply above 40F
  • Service Temperature -40ºF to 250ºF
  • Service life over 100 years
  • No VOC gt LEED Points
  • SPEC SHEET

38
Case Study 1
39
Case Study 2
40
California
41
California
42
New Mexico
43
Wisconsin
44
INDUSTRY STANDARDS
  • INSTALL DESIGN CONSIDERATIONS
  • LIGHT COMMERCIAL
  • RESIDENTIAL

45
(i) Building Codes Regulatory Compliance
  • ICC PMG 1023 Listing October, 2008
  • Code Compliant with IMC
  • Code Compliant with UMC
  • Code Compliant with IRC
  • LA Approval

46
(ii) Building Codes Regulatory Compliance
  • Future Code Compliance with 2009
  • SMACNA IECC (International Energy Conservation
    Code)
  • Ducts must be tested and must attain 2 leakage
    or less for compliance to energy code.
  • Amendment passed at ICC code Hearings in
    Minneapolis in September, 2008.

47
(iii) MN State Board of Appeals
  • Unanimous 5-0 decision by the State Board of
    Appeals comprised of 2 Architects, 2 building
    Inspectors and 1 engineer that AKDUCT meets the
    intent of the MN Energy Code of R-5 insulation
    required for underground air ducts, based upon
    tested thermal performance equivalency.

48
(iv) PVC Toxic Gas Generation
  • NIOSH states vinyl chloride is a known
    carcinogen.
  • OSHA has determined that Hydrogen Chloride is
    IDLH _at_ 50 ppm.
  • ( IDLH Immediately Dangerous to Life
    Health.)
  • PVC generates 1000 PPM of Hydrogen chloride under
    standard testing for Toxic Gas Generation.
  • 20 times the legal limit

49
EXAM Overview
  • Online Pre-Exam
  • Fill in the blank
  • Multiple choice
  • True and false
  • Match
Write a Comment
User Comments (0)
About PowerShow.com