Title: MTU CoCell
1MTU CoCell
CoCell Combination of MCFC and PEFC Optimisation
of the heat balance of a MCFC to produce
hydrogen for a PEFC
Lars Adamek MTU CFC Solutions GmbH Ottobrunn
2MTU CoCellQuestions to be answered
What do we do today ? What is the CoCell ? What
benefits do we expect ? Does it work ? Is it
sensible for any application ?
3MTU CoCellMCFC today
HotModule
Production of non-storable energies on demand
- Electrical energy (250 kW)
Utilisation of fuel 75
Electrical efficiency 45
Thermal efficiency 32
4MTU CoCellDisadvantages HotModule
- bad dynamic behaviour
- energy is not storable
- Hydrogen utilisation can not exceed 75
- ? excess Hydrogen is burned
Idea Why not using this Hydrogen electrically ?
5MTU CoCellMCFC as reformer
System border
Gasflow ? ? utilisation ? ? el. efficiency ?
6MTU CoCellChanges in MCFC
Anode
7MTU CoCellChanges in MCFC
Cathode
8MTU CoCellChanges in MCFC
9MTU CoCellAdvantages of configuration
Better suitable for load variations, due to lower
utilisation ? heat gradient in cell is smoothed
10MTU CoCelllimiting factors
Energy balance
11MTU CoCellAutothermal utilisation
QFC f (ut, ?, iMC)
QRef f (nCH4)
QSys f(ut)
QSys 0 f(ATU)
To determine ATU thermodynamic model of plant is
needed !
12MTU CoCellProducing or using H2?
H2 is fed to PEFC directly to increase el.
utilisation
H2 is stored and supplied to cars
CoCell
H2Fill
- Changes in mode of operation
- System has to be heated sufficiently
Cleaning of H2 is necessary
13MTU CoCellWhy use in PEFC ?
- high electrical efficiency
- increased electrical utilisation of hydrogen
- power density of PEFC is high
? increased overall efficiency by CoCell ?
14MTU CoCellThermodynamic Modell CoCell
15MTU CoCellThermodynamic Modell H2Fill
16MTU CoCellIncreasing heat supply
4 Methods to increase heat supply to increase
hydrogen production
S1 Nitrogen in Feed as heat carrier
S2 Prereforming of fuel
S3 Increase of current density im MCFC
S4 Increase of preheated air supply
17MTU CoCellStudy results
18MTU CoCellExperimental results
Maximum current density limited by
TCX lt 680C
UA lt 137 mV
19MTU CoCellExperimental results
H2-Filling Station
ut 40
The HotModule fuel cell enables a clean,
reliable and efficient conversion
20MTU CoCellPossible applications
Ships
21MTU CoCellAim of CoCell in ships
(neglecting parasitic losses)
22MTU CoCellPerformance of CoCell system
iMC,max 280 mA/cm² iPE,max 520 mA/cm²
23MTU CoCellenergy density
24MTU CoCellConclusion
Increase Energy density by factor 3
1/3 of Volume or Weight
Increasing efficiency
Increasing capital cost
Opening new market segment for big propulsion
systems
Making Fuel cells available for ship propulsion