Title: Workpackage 3: Thermal System
1Workpackage 3 Thermal System
Meeting, February 2, 2006 at EPFL
NMW
A. Bolleter, P. Müller
2Outline Presentation
First Version of test set-up Comparing
measurements and simulation Thermal System
Demonstrator Summary
3Measurement Setup
Tested insulation Dummy-Stack with heat
source Known insulation material
(MicroTherm) Positions of the measured
temperatures Wire of the thermocouple Wire for
the heat source Used sensors Thermocouple Type K
Setup only to test different insulations.
43D Model
Aerogel
Viewpoint A
Wire
Stack
MicroTherm
Viewpoint A
Wire
5Simulated Temperature Distribution
Viewpoint A
Viewpoint A
6Improved Measurement Setup
Tested insulation Dummy-Stack with heat
source Known insulation material Positions of the
measured temperatures Smaller diameter of wires
to reduce heat losses along wires
Setup only to test different insulations.
7Thermal System Demonstrator
..for measurement with and without flow with
different insulation
8Dummy Stack and Heat Exchanger
- Open issues
- Connection MICA Foturan
- Adhesion conductor / heating element
- Connection conductor path to heating element
- Dimension
9First test connection MICA Foturan
MICA
Foturan
- .failed
- Something happened with MICA !?
- Only one test strip survived
- Possible improvements
- Crystallizing Foturan
- Lower temperature
- Etching step
1 hour _at_ 900C
Mechanical hand load
10Summary
- Summary
- Wires have great impact on the system
- Measurement Setup needs to be improved
- Design of demonstrator is done
- Tackling open issues
- Ongoing Tests
11Next Steps
- Next steps
- To improve measurements
- To design demonstrator Test open issues
- To fix dimensions of demonstrator
12Questions ?