Title: high%20quality%20glass%20columns
1Kronlab Glass Columns
- high quality glass columns
- for lab scale to process scale
- solvent resistant and/or biocompatible design
- designed for low, medium and high pressure column
chromatography
2Product Lines
- Eco
- lab scale
- low / medium pressure
- ECOPLUS
- extended pressure rating up to 80 bar
- lab scale to prep
- Classic
- lab scale
- medium pressure
- conical tube
- BioCart
- lab scale to prep
- glass cartridges
- medium to high pressure
- Pilot
- pilot scale to production scale
- custom designed
- solvent resistant or for aqueous buffers
3Pilot Columns for Pilot to Production Scale
4Pilot Columns for Pilot to Production Scale
- designed for use in pilot and production scale
- designed for use with organic solvents (version
SR) or aqueous buffers (version AB) - outstanding flow distribution for a linear flow
distribution profile - high precision manufacturing of plungers and
distribution plates with CNC milling machines, no
injection moulding involved
5Pilot Columns for Pilot to Production Scale
- full documentation for validation
- full service and support for custom designed
columns - materials are in compliance with FDA regulations
CFR 21, certified if needed - precise and reliable height adjustment of the
piston with hand wheels - mounted either on castors or fixed stand or
directly into customers plant
6Pilot Columns - Wetted Materials
- column tube calibrated borosilicate glass or
stainless steel (steel quality to customers
specification) optional acrylic - piston PE, PTFE, PVDF or stainless steel
- seals EPDM or Kalrez
- frits PE, stainless steel, others on request
7Pilot Columns - Sizes
- columns from 60 mm to 600 mm ID
- length on demand
8Pilot Column -Design of Flow Distributor
flow distribution profile proofed by Bayer AG and
Kronlab GmbH
9Pilot Column -flexible inner diameters
PI 450
PI 60
PI 140
PI 100 Cooling Jacket
PI 100
Flow distribution profile proofed by Bayer AG and
Kronlab GmbH
10Pilot Column -flexible column material
stainless steel
glass or acrylic
11Pilot Column -flexible pressure ranges
50 bar
8,7 bar
10 bar
1 bar
12Pilot Column -integration of user demands
e.g. rotable frames, integrated level indicator,
brackets, selected materials, connectors .
13Pilot Columns - Custom Design
- special solutions for individual needs regarding
- materials
- design
- size
- system integration
14Pilot Columns - Custom Design
- individual feasibility studies and technical
drawings - certification
- competent guidance throughout the whole project
15Pilot AB - rotatable
column id 200 mm max. bed height 1600
mm pressure rating 7 bar specially designed
rotatable frame construction
16Pilot SR solvent resistant
technical specifications column id 200 and
300 mm max. bed height 400 mm pressure
rating 1.5 bar explosion-proof environment with
antistatic protection and wheels
17Pilot SR stainless steel
technical specifications column id 100
mm max. bed height 1000 mm min bed height 500
mm pressure rating 40 bar sealing Kalrez
18Pilot SR stainless steel
technical specifications column id 150
mm max. bed height 900 mm min bed height 700
mm pressure rating 50 bar sealing Kalrez
19Pilot AB - Reactor
- id 300 mm
- bed height 0- 500 mm
- pressure rating 1 bar
- frit 30 µm
- (SS 1.4404)
- special features
- slurry inlet
- integrated magnetic stirrer on
- cambered bottom frit
- piston with scraper
- special designed column stand
20Pilot AB -rotatable
id 240 mm bed height 0 - 270 mm volume 0-12
l pressure rating 3 bar cooling jacket 15 -
65C SS - container 15 l for slurry
waste frits 10 µm PE 5 mm thicknessspecially
designed frit fastening screwsto ensure perfect
flow distribution
21Pilot Columns - stainless steel
id 600 mm max. bed height 1000 mm (1500
mm) bed volume 282,6 l (423,9 l) pressure
rating 10 bar frits 10 µm
22Pilot Column - stainless steel
Example
id 600 mm max. bed height 1000 mm (1500
mm) bed volume 282,6 l (423,9 l) pressure
rating 10 bar frits 10 µm
designed for repeated packing and unpacking
without opening the column
23Solvent Inlet
Example
Slurry-Inlet through separate slurry pump
Slurry-Outlet through central outlet valve
Solvent Outlets
24Pilot Columns - References
- Abbott
- Aventis
- Baxter Hyland Immuno AG
- Bayer AG
- Biotest
- Clariant
- Genetics Institute
- Genzyme
- Honeywell
- Novartis AG
- Schering AG
- Roche Diagnostics
- etc