Nitrosamine Detection in Meat
  • By Beryl Ombaso,
  • Chemistry 4101,
  • Fall 2008

2
BACKGROUND
  • Nitrite is added to meat both for preservation
  • and color enhancement.
  • Amines in the meat react with the nitrite to
  • form nitrosamines which are known
  • carcinogens.1
  • NO2 H HNO2
  • 2HNO2 N203 H20
  • N203 R2NH R2N.NO HNO2
  • (a nitrosamine)

3
Tumorgenic levels of Nitrosamines
Nitrosamine TD50, mg/kg body weight/day Expected levels in typical sample, µg/kg
Nitrosodimethylamine 0.01 1.90 2.37
Nitrosodiethylamine 0.11 0.33 0.54
Nitrosopyrrolidine 2.10 2.32 8.94
Nitrosopiperidine 1.30 0.5 1.31
Nitrosodibutylamine 0.69 0.16 0.24
  • USDA recommended exposure level-10 ppb.2

4
Methods for Nitrosamine detection
Method Limit of Detection Linear range Special notes
Spectrophotometry3 0.78ppb 25 to 2000 ppb Derivatization with Griess reagent.
Electroanalysis4 6.0 x 10-8 mol L-1 2 x 10-6 to 1.35 x 10-5 mol L-1 Determine total nitrosamines
HPLC/Fluorescence5 0.04 ppb 0.04 to 1.05 ppb. Derivatization with Dansyl chloride.
5
Proposed Method for Nitrosamine Detection
  • Gas Chromatography with tandem MS would be most
    ideal.6
  • Nitrosamines are highly volatile and thermally
    stable.
  • Limit of detection 0.01 ppb.
  • Linear range 0.01 to 10 ppb.
  • Percent recovery 70-80 .
  • Efficient separation and ease of use.

6
Instrumentation
7
SAMPLE PREPARATION
  • Interfering species amines, amino acids.
  • SPE limits amount of interfering species.
  • Blank sample consists of 0.1N NaOH.

8
Experimental conditions6
  • Combination of Extrelut-Florisil cartridge for
    SPE.
  • Column 30 m, 0.25 mm i.d, 0.25 µm film
    thickness containing 16 cyanopropylphenylmethyl
    polysiloxane.
  • Carrier gas Helium gas at 1.0 mL/min.
  • Oven initial temp. 500C, final temp. 2600C
  • Injection volume- 2.0 µl
  • Outlet pressure 54.8 kPa
  • Electrospray ionization at 70eV.
  • Reagent for chemical ionization- ammonia gas.
  • Quadrupole mass selective detectors for analysis.

9
Sample Chromatogram
10
Sample Mass Spectrum
  • Quantification accomplished by using calibration
    curve obtained from standards.
  • Standards obtained easily from manufacturer.

11
Equipment model
  • HP 5890A/5970 GC/MS
  • Cost 9,950
  • Oven temp up to 4500C
  • Compact size
  • Power supply 120V
  • Resolution 0.1amu
  • S/N 201
  • Scan speed 1500 amu/sec
  • Mass range10 800 amu
  • Gentechscientific.com

12
References
  • 1. Mirvish, S. Cancer letters, 1995, 93,
    17-48.
  • 2. Jay, J. Modern Food Microbiology, 6th Ed,
    2000, pg 261.
  • 3. Perez, E. L. Rios, A. Valcarcel, M. J
    Anal. Chem, 2001, 371, 891-895.
  • 4. Oliveira, R. T. Salazar-Banda, G. R.
    Machado, S. A. Avaca, L. A. Electroanalyis,
    2008, 20, 396-401.
  • Cardenes, L. Ayala, J. H. Venerando, G.
    Afonso, A. M. J. Liq. Chrom. Rel. Technol.,
    2002, 25, 977-984.
  • Jurtchenko, S. Tenno, T. Molder, U. Reinik,
    M. Proc. Estonian Acad. Sci. Chem., 2002, 51,
    169-184.