EXERGY
  • Real-time Efficiency Analysis for Power Stations

2
The issue
  • You need the ability to detect and diagnose
    efficiency problems in a thermal power station.
  • You need your operators to be able to react to
    the diagnoses and restore the unit to a higher
    efficiency.
  • This can add significantly to the operational
    profits of the station and result in lower CO2
    emissions.

3
EXERGY Real-time Efficiency analysis
  • Less Fuel Less CO2 More profit

4
What is EXERGY?
  • EXERGY is a tool for detecting and diagnosing
    efficiency problems in thermodynamic processes
  • EXERGY saves operating costs. It has a unique
    ability to detect problems, diagnose causes and
    recommend remedial actions. It also allows
    operators to prioritise problems by providing an
    estimated cost per hour of the problem.

5
What is EXERGY?
  • EXERGY is the ONLY software available for
    continuous efficiency monitoring that is based on
    sound physics.
  • EXERGY gives you continuous online efficiency
    monitoring
  • EXERGY lets you pinpoint efficiency losses
  • EXERGY delivers instant reporting and diagnostics
  • EXERGY finds the root cause of problems,
    automatically
  • EXERGY is the only software that calculates 2nd
    Law efficiency for your power station processes.
    It allows trending of component efficiencies and
    drill-downs to locate sources of problems .

6
How EXERGY works Background
  • Plant efficiency management in the first instance
    is concerned with the Heat Rate, a 1st Law
    measure of efficiency.
  • Ultimately a plant wants to produce as much
    output for the least expenditure of fuel.
  • When plant efficiency deteriorates, either
    through incorrect operation, sudden failure in a
    component or through gradual loss of condition,
    the challenge is to find the cause and then cost
    the value of repairs.
  • 1st Law measures of component efficiency are not
    useful for this analysis.

7
How EXERGY works Background
  • In contrast, 2nd efficiency measures are ideally
    suited for this task.
  • Exergy (availability) losses are additive (i.e.
    the total exergy loss for the plant is the sum of
    all the component losses), enabling attribution
    of the losses to plant components.
  • The plant is modelled as a hierarchy of
    components, starting with entire plant. Losses
    can be tracked from top level of the plant to
    individual components.

8
How EXERGY works Background
  • Entropy is additive
  • Entropy (and Exergy) is not a conserved quantity
  • Unit heatrate trend correlates exactly with
    Exergy loss trend
  • These properties enable a quantitative method for
    determining the root cause of heat rate
    excursions.
  • The resultant diagnostics procedure is valid both
    for short term ( real time) and long term.

9
Thermal Plant Efficiency
  • The plant state at commissioning should be
    optimal
  • Variance from optimal due to
  • Gradual deterioration of components
  • Failure of components
  • Sub-optimal/incorrect operation
  • EXERGY detects the root cause of any efficiency
    loss.
  • Alarms when efficiency excursions occur with
    operating recommendations

10
EXERGY alarms
  • Efficiency excursions result in alarms
  • Alarms go to
  • Email if desired.
  • Client PCs
  • A central database

11
Example Exergy alarm
12
Exergy Alarm Analysis
13
An example EXERGY audit Bayeswater Station, NSW
14
EXERGY audit as it happened, Bayeswater
15
Exergy audit as it happened, Bayeswater
16
Real Measurements, Bayeswater
17
Overview of Exergy Components
18
EXERGY installation
  • Installs on MS Windows Server
  • Interfaces with OsiSoft PI
  • But custom interfaces can be used instead
  • Reads instrumentation writes back results
  • Communicates with clients over TCP/IP network