Title: Alarming Temperature Read-backs Status 4-August-03
1Alarming Temperature Read-backsStatus
4-August-03
- TCT Temperature Control Temperature Alarms fixed
by moving bayonet out/in - 7B5/TCT8 needs to be fixed
- Had the same problem before, bayonet was
re-inserted on May 10 - 6B5/TCT8 fixed 29-July-2003, still good
- 4B1/TCT8 fixed 15-July-2003, still good
- 8A7/TCT6 fixed 28-June-2003, still good
- NEW BIZZARE Temperature Control for 8A1
2 8A7, still good August4-2003
34B1 still good on August 4, 2003
44B1 bad in June 03
54B1
66B5, Bayonet out/in 29-July-034-Aug-03 still good
78A7, board 515
84B1 board 503
9Bayonet out/in 8A7, June-28 7AM
10Temperature read-back on 8A7 is fixed
116B5, Bayonet in/out 29-July-03
127B5
13Temperature oscillating in 7B5 module 8
- Stopped oscillating after re-inserting of bayonet
14Temperature Control Problems
Major Temperature control Alarms for 8A1. In
the morning of August 2, Major Alarm persisted on
heater voltage in module 1 of cassette to which
board 8A1 is attached CFTA_AFE_8A1/TCOV1. I
removed it by clicking first temperature control
off and next temperature control on in AFE_8A1
menu, this menu is available from
cft_gui-gtdetails(VRBCR_50)-gtAFE_8A1. However I
think that 8A1 developed temperature control
problem and it may again cause Major Alarm. You
might like to call expert or/and me when that
will happen. I see two ways of dealing with
persistent temperature control Major Alarms for
this board. First you may repeat what I did. You
will have several Major Temperature control
Alarms after clicking temperature control off but
they should disappear in a few minutes after you
clicked temperature control on. If that fails you
may set temperature control in this board to
manual by clicking temperature control manual .
In this mode heater voltages are set to constant
values. The voltages are taken from database,
they are available by right clicking on AFE_8A1
menu. tcov1 is voltage for heater for module 1.
The heater voltages may need adjustment. To see
in which direction they should be changed you
need plot cryo for VRBCR_50 and store new values
in database. For new voltages to take effect you
need click again temperature control manual.
158A1 module 8 Heater Turns itself offTemperature
Control Off/On fixes