Title: Common Water Treatment Problems


1
Common Water Treatment Problems
Hard Water -Calcium and Magnesium. Soap Scum, and
Scale Build-Up. Iron - Clear (Ferrous), Red
(Ferric), Bacteria Related Iron. Stains
Red Manganese -Similar concerns as Iron, but
usually stains Black. Total Dissolved Solids
(TDS) -Indicates the total amount of dissolved
minerals in the water. This would include the
Hardness, Iron and Sodium, but not Bacteria or
H2S. Bacteria -Microorganisms that multiply and
feed from the elements in water. Can be very
harmful, such as Fecal Coliform, or only an
aesthetic concern like Iron Bacteria. Arsenic
-Now considered one of the poisonous elements in
water. Must remove at very low amounts (0.01
mg/l). Tannins -Decaying vegetation in water.
Gives water a tea colour. Hydrogen Sulfide (H2S)
-In a gas form, and gives a Rotten Egg smell to
the water. Will normally dissipate when exposed
to atmosphere, but can be associated to Bacteria
concerns, and in high enough levels, could be
harmful.
2
Water Softener Tannin/Colour Remover
Iron Filter
Control Valve
Control Valve
Direction Of Flow
Brine Line
Resin Tank
Mineral Tank
Regenerate Line
Brine Tank
Drain Line
Pot. Perm. Feeder
Air Gapped Drain
3
Reverse Osmosis Systems-When and Where Does It
Fit?
  • An RO reduces TDS. The conductivity of the water
    is effected by the TDS in the water. Generally
    speaking, Low TDSLow Minerals and Salts in
    water.
  • RO systems are considered a purifier, due to the
    reduction of the TDS, thus bringing water closer
    to its original form, without the elements found
    in TDS.
  • Use RO systems when water has taste or smell
    concerns. Use RO water for an health related
    concern.
  • An RO should always be the last product in the
    treatment chain, except if an UV is used for post
    RO protection.
  • An RO should only be used, whenever possible, on
    clear Microbiological safe water.

Giardia Cryptosporidium Cysts 99.99
Sodium 95 - 99 Nitrate 90
- 99
Arsenic 5 95 -99 Lead
95 - 99
Copper 95 - 99

4
(No Transcript)
5
(No Transcript)
6
5 Stage Reverse Osmosis System
7
Ultraviolet Light (UV) Disinfection Systems
  • For the disinfection or sterilization of
    microorganisms.
  • Specifically, UV affects the DNA structure of a
    Bacteria cell. The sterilized Bacteria can not
    reproduce. Now considered harmless.
  • The flow through a UV is critical for effective
    dosage. Flow Control
  • The water quality entering the UV MUST be clear,
    or low in Turbidity.
  • A sediment cartridge rated _at_ 5 Micron, minimum,
    should always be used to pre treat the water,
    along with appropriate Filtration.
  • A UV is always installed after pretreatment
  • Often used at the point of entry (POE), a UV is
    more effective installed as close to the point of
    use (POU) as possible.

8
UV System
  • Flow GPM must be regulated to rating of UV
  • Incoming water must be clear in colour
  • Maintain constant power to unit
  • Use surge protectors

9
Chemical Feed Pump Systems
  • Two types are most common
  • Solenoid/Diaphragm ( Pulsafeeder, LMI,)
  • Peristaltic ( Stenner )
  • Both styles can be 115V or 230V.
  • Both can be on/off or remote controlled.
  • Both require attention to chemicals used, and
    sizing requirements.
  • Sizing a Pump
  • Well Pump GPM x Required Dosage PPM x 1440 /
    Solution Strength PPM Feed Rate in GPD
  • Dosage Calculations
  • 1 PPM Bleach 1 PPM Iron, 3 PPM Bleach 1 PPM
    H2S,
  • Plus add required residual to dosage. ( 0.5 to
    1 PPM)
  • Solution Strength
  • 5 Bleach 52,500PPM. 12.5 Bleach 125,000PPM.
  • Choose a pumps max. output that is twice the GPD
    required.
  • Rule of thumb for contact time is 20 Minutes.
    Actual pH and temp. of water does have an impact
    on contact time required.

10
Non-Chlorinated Outside Service Line. If Required.
Optional Chemical Pump Flow Meter
To Service Line
Contact Tank
Pressure Tank
Check Valve
Multi-Media Filter
Carbon Filter
Injection Point
Chemical Injection Pump, and Solution Tank.
Standard Chlorine Pump System C/W Non-Chlorinated
Outside Service
Well Pump
11
To Drinking Water Faucet
Usual Sequence or Placement of Common Filtration
Products
RO System
5 Micron Sediment
Water Softener
Carbon Filter
Multi-Media Filter
Iron Filter
UV
Pressure Tank
Pot.Perm. Feeder
Brine Tank
Well Pump