Title: The Solar Protection Relay by BCJ Controls | Comap IntelliPro


1
Solar Protection Relay
  • Subtitle

2
Title and Content Layout with List
  • ABB REG630 Solar Protection Relay
  • Schneider Easergy Micom p341
  • Fanox SIL-G Protection Relay
  • Zero Export Controls CEC2000
  • Zero Export Controls CEC3000
  • Zero Export Devices ZED 1, 2, 3, 4 GNT
    Engineering
  • MFR300 Multi-function Relay

3
ABB REG630 Solar Protection Relay
  • The ABB REG630 Protection Relay is a zero export
    protection relay often used for solar PV embedded
    generation.
  • REG630 is a comprehensive generator management
    relay for protection, control, measurement and
    supervision of small and medium-sized power
    generators and generator-transformer units in
    utility and power distribution systems.
  • REG630 is a member of ABBs Relion product family
    and a part of its 630 product series. The 630
    series relays are characterized by functional
    scalability and flexible configurability. REG630
    has been designed to be the main protection for
    synchronous generators, offering full protection
    during start-up and normal run for both the
    generator and the prime mover. REG630 is
    typically used in small and medium-sized diesel,
    hydroelectric, combined heat and power (CHP), and
    steam power plants.

4
ABB REG630 Solar Protection Relay
  • The pre-defined configuration is intended for
    directly connected generator sets and can either
    be used as such or easily tailored to
    application-specific requirements with freely
    selectable functions.
  • REG630 can be used in either single or
    double-busbar applications with one or two
    breakers and numerous switching devices. It also
    supports a substantial number of both manually
    and motor-operated disconnectors and earthing
    switches. REG630 can therefore be used to control
    various types of switchgears.
  • REG630 fully supports the IEC 61850 standard for
    communication in substations and covers both
    vertical and horizontal communication, including
    GOOSE messaging with both binary and analog
    signals. REG630 also supports the DNP3 (TCP/IP)
    and IEC 60870-5-103 (serial) communication
    protocols. The supported communication protocols,
    including IEC 61850, offer seamless connectivity
    to various station automation and SCADA systems.

5
Why ABB?
  • Flexible generator protection relay for
    synchronous generators
  • Differential protection, 3rd harmonic-based
    stator earth-fault protection, reverse power
    protection and extensive interconnection
    protection for distributed generation
  • Control of two circuit breakers and a total of
    eight disconnectors and earthing switches
  • Freely configurable functionality to meet
    application-specific requirements
  • Large, integrated or detached HMI

6
Shneider Easergy MiCom p341
  • Easergy MiCOM P341 Interconnection protection
    relays can be customized to meet the specific
    needs of the intended application. They offer
    complete, cost-effective and highly reliable
    protection for operating machines. It also
    includes Dynamic Line Rating (DLR) protection to
    optimize transmission line capacity. Gains of 50
    or more can be achieved, depending on the
    environmental conditions, enabling more
    Distributed Generation (DG) such as wind farms to
    be connected to the grid by taking into account
    the real time weather conditions to calculate the
    line rating compared to using the fixed
    summer/winter line ratings. DLR is a cost
    effective alternative to reinforcing overhead
    lines to increase capacity and there are also
    benefits to the wind farm owner in that higher
    revenues can be made with a higher line rating.

7
Shneider Easergy MiCom p341
  • Extensive multi-functions and user-friendly logic
  • Multi-function relay range ensures flexible,
    reliable integration of protection, control,
    monitoring and measurements for a wide variety of
    system applications
  • Users can create complex protection schemes by
    using Easergy MiCOMs powerful, user-friendly
    logic
  • Quality choice of industry standard protocols are
    available, facilitating integration into both new
    and existing network control systems
  • Flexible communications and cost-effective
    solutions
  • Easergy MiCOM relay familys extensive protection
    functions meet the requirements for most
    interconnection and DLR protection applications
    and provide them with cost-effective solutions
    and offers flexible communications options
  • Latest communication protocols Ethernet
    Redundancy (available now in P341)

8
Shneider Easergy MiCom p341
  • Fully Equipped with the latest communications
    protocols (IEC61850 Ed1 Ed2 available in the
    same device, selection by setting)
  • Maximum availability and reliability of Ethernet
    communications thanks to the implementation of
    PRP/HSR standard redundancy protocols with an
    instantaneous recovery time in case of network
    failure
  • Dual IP address allows the device to be connected
    to 2 independent communication networks (e.g,
    SCADA system network Maintenance network)
  • Universal IRIG-B input (automatically detects
    modulated or unmodulated signal)
  • Major enhancement to Cybersecurity
  • Operational Cyber Security, compliant to IEC
    62351, helps protect installations with security
    based on embedded features such as Role Based
    Access Control (RBAC), Port Hardening, Security
    Logs and Access Traceability. The IED by default
    includes RBAC with different users defined and a
    Security Administrator.

9
Fanox SIL-G
  • Protection functions available in SIL-G are the
    following
  • 81R, 78, 81 U/O, 27P, 32/40, 59P, 59N, 25, 79,
    50P, 50N/G, 67P, 67N, 46, 79, 50BF, 52, 49,
    86,CLP, 49T, 74TCS, 37 and IRIG-B
  • Monitors differences in voltage magnitudes, phase
    angles, and frequencies to perform synchronism
    checks across the circuit breaker, can be
    coordinated with the auto-reclose function (up to
    five recloses)
  • Used with auxiliary power supply (110-230 Vac/
    90-300 Vdc and optionally 24-48 Vdc)
  • Two rear ports on the back for remote
    communication
  • Two communication protocols can be used
    simultaneously MODBUS RTU and IEC 60870-5-103,
    IEC 61850, DNP 3.0 or IEC 60870-5-104

10
Fanox SIL-G
  • Physical Features
  • Metallic box with high electromagnetic
    compatibility level (EMC) and wide range of
    operating temperatures
  • Direct signalling/control on both of the circuit
    breakers(52 function) and both of the reclosers
    (79 function)
  • Reduced size makes the SIL-G relay easy to
    install and its light weight helps the customer
    to save costs in transport
  • 8 configurable inputs and 7 configurable outputs
  • 2 Oscillographic records, 20 fault reports and
    non-volatile RAM memory stores 1.000 events with
    date/time even without power supply thanks to its
    internal RTC

11
CEC2000
  • Real time data interface
  • Configuration page has adjustable parameter
    settings to suit the requirements of any network
  • Zero Export to grid
  • Mechanically isolated
  • Six switching points
  • Export/Import Value Enabler
  • Anti-islanding
  • Ovevoltage and undervoltage protection
  • Under- and Over-frequency protection
  • Phase Failure Protection
  • Reverse Power Protection
  • ROCOF (rate of change of frequency)
  • Phase rotation detection
  • Error messages on faults
  • Email alerts
  • Self Calibrating
  • Real time clock
  • Internal battery backup
  • Internal watchdog

12
CEC3000
  • Real time data user interface
  • Configuration page with adjustable parameter
    settings to suit the requirements of any network
  • Zero Export to grid
  • Mechanically isolated
  • Six switching points
  • Export/Import value enabler
  • Export Allows controlled export to the grid as
    per the utility agreement (i.e. 100 kW approval
    with 20 kW allowable export)
  • Import Satisfies need of a required minimum
    import of electricity to the site that some
    systems need

13
CEC3000
  • Monitors and logs data (i.e. KVA, Voltage,
    Current, Power factor, frequency etc.)
  • Real time data mobile viewing
  • Collect and store data on off site server for 10
    years
  • Anti-islanding
  • Overvoltage and undervoltage protection
  • Under- and over-frequency protection
  • Phase Failure Protection
  • Reverse Power Protection
  • ROCOF (rate of change of frequency)
  • Phase rotation detection
  • Error messages on faults
  • Email alerts
  • Self Calibrating
  • Real time clock
  • Internal battery backup
  • Internal watchdog
  • Multi layer password protection
  • USB and lan ports
  • Used with all inverter brands

14
ZED Relays
  • Inverter Control/Solar PV Production
  • The ZED devices communicate with the inverter via
    three (3) protocols, the choice of protocol is
    dependent on specific inverter compatibility.
    These protocols are 4 or 6 bit binary and RS 485
    protocols. The 4 bit binary provides 16 levels of
    solar PV production between 0 and 100. The 6 bit
    binary provides 64 levels of solar PV production
    between 0 and 100.
  • RS 485 provides solar PV production in 1
    increments.

15
ZED Relays
  • 2.1 Compatible Inverters
  • There is a range of inverters that are compatible
    with the ZED family of devices can manage Solar
    PV production and deliver Zero Export.Inverters
    which can be controlled via 4 or 6 bit binary
    will require a management card supplied by the
    manufacturer of the inverter these are often
    referred to as Power Control Modules, Power
    Management Units, Data Managers or
    controllers.Inverters that have RS 485/Modbus
    connection are managed via inverter specific
    protocols.Inverter performance and compatibility
    with the ZED family has been validated by GNT
    Engineering.
  • To date a number of inverters have been validated
    by GNT Engineering and are managing Zero Export
    solutions for 3 phase and single phase
    installations.

16
ZED Relays
  • 2.2 Inverter List
  • 4 Bit Binary  Fronius, SMA, Solar Edge, ABB
    ZeverSolar6 Bit Binary FroniusMODBUS RS485
    ABB, Schneider, Fronius,GoodWe, Delta, Omnik,
    Samil ZeverSolarUnder Development

17
MFR 300
  • Other Solar Protection Relays are available here
  • The MFR 300 is a measuring transducer for
    monitoring single-phase and three-phase power
    systems. With both voltage and current inputs in
    order to allow this relay to measure an
    electrical power source. A digital processor
    carefully measures true RMS values, despite
    harmonics, transients, or disturbing pulses. Both
    the primary measured and the calculated values
    may be transmitted using the CAN open interface
    to a managerial control system. The MFR 300 looks
    at mains decoupling with various monitoring
    functions that include two time-dependent, freely
    configurable, undervoltage tracking functions for
    FRT and STI. The real, reactive, and apparent
    power and the power factor values are calculated
    using the primary measured values of voltage and
    current.

18
MFR 300 Features
  • Three true RMS voltage inputs Three true RMS
    current inputs Class 0.5 accuracy for voltage,
    frequency, and current Class 1 accuracy for
    real and reactive power or energy Configurable
    trip/control set points Configurable delay
    timers for individual alarms (0.02 to 99.99 s)
    Four configurable relays (change-over)
    Ready-for-operation relay 2 kWh counters (max.
    1012 kWh) 2 kVARh counters (max. 1012 kvarh)
    Programmable relay outputs to annunciate alarms
    CANopen communication Configurable via CAN
    bus 24 VDC power supply

19
MFR 300 Protections
  • Over- and under-voltage Over- and
    under-frequency Voltage asymmetry Overload
    Rev/red power Unbalanced load Phase shift
    Rate of change of frequency Freely configurable
    time-dependent undervoltage monitoring for FRT
    (fault ride-through) and STI (short-time
    interruption)

20
BCJ Controls
  • BCJ Controls - commercial solar network
    protection unit - switchboard manufacturing
    including protection relay anti-islanding and
    zero export devices. BCJ Controls is a solar
    technology company set up by ex-utility
    industrial sparkies. Between them they have a
    large amount of experience in electrical grid
    protection, as well as dealing with utilities on
    a day-to-day basis.
  • At BCJ Controls we produce Secondary Protection
    Switchboards with solar protection relays for
    Commercial Solar over 30kW grid connections.
  • We offers installation, testing, commissioning,
    also we have a different protection relays. Call
    us (02) 9534 8465.

21
BCJ Controls
  • 2,17 Lorraine St, Peakhurst NSW 2210
  • http//bcjcontrols.com.au/