Data center Tiers (I-IV) Explained - PowerPoint PPT Presentation

About This Presentation
Title:

Data center Tiers (I-IV) Explained

Description:

Tier classifications in a data center signify a standardized methodology used to describe site level infrastructure required to sustain data center infrastructure analyzing its expected availability (performance), functionality and capacity. – PowerPoint PPT presentation

Number of Views:1049

less

Transcript and Presenter's Notes

Title: Data center Tiers (I-IV) Explained


1
Data center Tiers (I-IV) Explained
  • Data Center Tiers (I-IV) Classification as per
    Uptime Institute

2
What do Data center Tiers signify?
  • Tier classifications in a data center signify a
    standardized methodology used to describe site
    level infrastructure required to sustain data
    center infrastructure analyzing its expected
    availability (performance), functionality and
    capacity.

3
The 4 Data Center Tiers
  • Tier 1- Basic Data center Site Infrastructure
  • Tier 2 - Redundant Site Infrastructure Capacity
    Components
  • Tier 3- Concurrently Maintainable Site
    Infrastructure
  • Tier 4- Fault Tolerant Site Infrastructure

4
Evaluation Parameters of Data Center Tiers
  • The Tier number designation to any data center is
    based on the evaluation of following parameters
  • Investment
  • ROI (return on investment)
  • Infrastructure

5
Tier 1- Data center Site Basic Infrastructure
  • Expected Availability- 99.671 Uptime/year
  • No redundancy
  • 28.8 hrs of downtime/year
  • Susceptible to operational human errors
  • Demands annual maintenance requiring site-wide
    shutdown

6
Tier 2 - Redundant Site Infrastructure Capacity
Components
  • Expected Uptime- 99.749 Uptime/year
  • Partial redundancy in power and cooling
  • Experiences 22 hours of downtime/year
  • Susceptible to operational human errors
  • Demands annual maintenance requiring site-wide
    shutdown
  • Component removal doesnt impacts computer
    equipment

7
Tier 3- Concurrently Maintainable Site
Infrastructure
  • Expected availability- 99.982 Uptime/year
  • Max 1.6 hrs of downtime/year
  • N1 fault tolerant providing at least 72 hours
    power outage protection
  • Facility to manage maintenance periods without
    affecting the continuity of service on the
    servers
  • Less susceptible to operational human errors
  • Annual maintenance without operational shutdowns

8
Tier 4- Fault Tolerant Site Infrastructure
  • Expected availability- 99.995 Uptime/year
  • 2N1 fully redundant fault tolerant
    infrastructure
  • 26.3 minutes downtime/year
  • Not susceptible to operational human errors
  • Annual maintenance without operational shutdowns

9
Data Center Tiers Summed Up
  • Tier 1 Non-redundant capacity components
    (single uplink and servers).
  • Tier 2 Tier 1 Redundant capacity components
  • Tier 3 Tier 1 Tier 2 Dual-powered equipment
    and multiple uplinks.
  • Tier 4 Tier 1 Tier 2 Tier 3 all
    components are fully fault-tolerant including
    uplinks, storage, chillers, HVAC systems, servers
    etc.

10
Thank You
  • Want further insights related to data center?
  • Just visit our official blog here-
  • www.rackbank.com/blog
  • Website www.rackbank.com
Write a Comment
User Comments (0)
About PowerShow.com