PEC Controller Tests - PowerPoint PPT Presentation

1 / 20
About This Presentation
Title:

PEC Controller Tests

Description:

OSU Tests on 10 HP Imperial. Rated Load. OSU Tests on 15 HP GE. Rated Load ... Goodwin Hotel Elevator. 1=idle, 2=empty car, 3=500#, 4=1000#, 5=1500 ... – PowerPoint PPT presentation

Number of Views:23
Avg rating:3.0/5.0
Slides: 21
Provided by: CEEP9
Category:
Tags: pec | controller | tests

less

Transcript and Presenter's Notes

Title: PEC Controller Tests


1
PEC Controller Tests
  • Excerpts

2
OSU Tests on 15 HP GE
Rated Load
3
OSU Tests on 10 HP Imperial
Rated Load
4
OSU Tests on 15 HP GE
Rated Load
5
OSU Tests on 10 HP Imperial
Rated Load
6
OSU Tests on 15 HP GE
--
--
7
OSU Tests on 15 HP GEOperating range of greatest
expected savings.
--
--
Escalator operating range based on HIA data.
8
OSU Tests on 10 HP Imperial
--
--
9
OSU Tests on 10 HP ImperialOperating range of
greatest expected savings.
10
ORNL Tests on 10 HP Lincoln
11
ORNL Tests on 10 HP LincolnOperating range of
greatest expected savings.
12
ORNL Tests on 50 HP Lincoln
13
ORNL Tests on 50 HP LincolnOperating range of
greatest expected savings.
14
Goodwin Hotel Elevator
1idle, 2empty car, 3500, 41000, 51500
15
Four Motors Idle Losses at Three Voltages From
OSU MSRF
16
Four Motors Efficiency at 25 Load at Three
Voltages From OSU MSRF
17
New 900 RPM Motor Stats
. sum eff_fl eff_25 if speed900 hp15
eff_25.

Variable Obs Mean
Std. Dev. Min Max
------------------------------------------------
-------------- eff_fl
14 88.59286 1.993629 86.3 91
eff_25 14 83.93571
3.522588 79.2 88.5

. sum eff_fl eff_25
if speed900 hp20 eff_25.


Variable Obs Mean Std. Dev.
Min Max -----------------
---------------------------------------------
eff_fl 17 89.58235
1.576085 86.5 91
eff_25 17 85.35294 3.229961
81.5 89

. sum eff_fl eff_25 if speed900
hp25 eff_25.

Variable Obs
Mean Std. Dev. Min Max
------------------------------------------
-------------------- eff_fl
16 89.88125 1.16974 87.5
91 eff_25 16
85.8125 3.597198 80 89.8
18
New 900 RPM Motor Stats
  • . sum eff_fl eff_25 if speed900 hp30
    eff_25.

  • Variable Obs Mean Std. Dev.
    Min Max
  • -------------------------------------------------
    -------------
  • eff_fl 15 91.66 1.383475
    89 93
  • eff_25 15 87.69333 2.363552
    82.3 89.9

  • . sum eff_fl eff_25 if speed900 hp40
    eff_25.

  • Variable Obs Mean Std. Dev.
    Min Max
  • -------------------------------------------------
    -------------
  • eff_fl 16 91.91875 1.35313
    89.4 93
  • eff_25 16 88.2375 2.009269
    83.3 90.2

  • . sum eff_fl eff_25 if speed900 hp50
    eff_25.

  • Variable Obs Mean Std. Dev.
    Min Max
  • -------------------------------------------------
    -------------
  • eff_fl 16 92.56875 .7656969
    91 93.6

19
New 900 RPM Motor Stats
  • . sum eff_fl eff_25 if speed900 hp75
    eff_25.

  • Variable Obs Mean Std. Dev.
    Min Max
  • -------------------------------------------------
    -------------
  • eff_fl 14 93.75 .6903173
    92.4 94.5
  • eff_25 14 90.62143 1.820472
    87.5 92.1

  • . sum eff_fl eff_25 if speed900 hp100
    eff_25.

  • Variable Obs Mean Std. Dev.
    Min Max
  • -------------------------------------------------
    -------------
  • eff_fl 14 94.07143 .3539423
    93.6 94.5
  • eff_25 14 90.80714 1.611719
    88.5 92.6

20
(No Transcript)