Title: System Details
1Signature System
2The Concept - from a small system
DataNode
DataNode
InfoNode
DataNode
DataNode
DataNode
3The Concept - to the enterprise level
DataNode
DataNode
InfoNode
DataNode
DataNode
DataNode
NodeLink
InfoNode
InfoNode
DataNode
DataNode
DataNode
DataNode
4Signature System that evolves with your needs
5InfoNode
Signature System
- Industrial computer or
- PC Based Web Server
6Signature System
- InfoNode System Gateway
- What is an InfoNode?
- Data concentrator and web server.
- Collects data from all monitoring instruments and
stored into a database - Built-in Web server compatible with IE, Netscape,
Modzilla, etc. - All user interactions are via a web browser via
any computer on the network. - Browse the InfoNode database. Trends, event
lists, real time, system setup - Available in 2 varieties
- Reliable industrial computer. Hard disk or CF
based - PC software
- Choose whats appropriate for your application
7Signature System
- InfoNode Series 5500 Industrial Computer
- 2 Models 5502 5504
- Differences are
- Memory Technology (hard disk vs. compact flash )?
- Temperature Range (based upon memory technology)?
- Common Options
- Answer Modules
- GPS
- Modem
- Mounting Brackets
- Misc. Cables Adapters
- DataNode Drivers
8Signature System
- InfoNode Model 5502
- Compact Flash (CF) memory Technology
- 32M standard, 64M 128M Optional
- Extended Temperature Range
- 0 - 65 C
- CE, UL
- Supports up to 5 DataNodes (with expanded
memory)? - Actual number depends on Datanode type and of
parameters recorded - When to use
- Where a turn-key, drop-in solution is required.
No software to install - Harsh environments. CF is more tolerant than a
hard disk. - Applicable for small systems that will not grow
larger than 5 Datanodes - Hacking and virus protection is a concern. Not
Windows based, not a target
9Signature System
- InfoNode Model 5504
- Hard Disk Memory Technology
- 2G DataBase
- Temperature Range
- 10 - 50 C
- CE, UL
- Supports up to 20 DataNodes
- Actual number depends on Datanode type and of
param.recorded - When to use
- Where a turn-key, drop-in solution is required.
No software to install - Hacking and virus protection is a concern. Not
Windows based, not a target - Environment is hard disk friendly
10Signature System
- PCInfoNode
- PC Based. Software to convert PC into an InfoNode
- Functionally the same as a 5502/5504 but runs on
a PC - PC should be a dedicated PCInfoNode
- Hardware key (USB HASP) software license
- 8GB database
- Lower cost (than 5502, 5504) solution.
- Customer or Dranetz-BMI supplies PC
- Supports greater than 30 DataNodes.
- Actual number depends on Datanode type and of
parameters recorded. - Choose PC InfoNode when one or more of the
following apply - Large systems
- Customer wants PC based solution
- Lower cost
- Environment is PC/hard disk friendly
11Signature System
- InfoNode Answer Modules
- Cap Bank Switch
- Was that Transient a Cap switch? Was it upstream
or downstream - VAR Verifier add-on. Did the cap switch in
properly. Delta VARS OK. - Sag Directivity
- Did that Sag originate at the source or load
- Distance to Radial Line Fault
- What is the distance from the monitoring point to
the fault - Energy Usage Management
- Energy reporting, aggregation and allocation
- UPS Verification
- UPS I/O correlation reports
- OneLine
- Custom facility one line with real time
monitoring points overlaid - Generic Modbus Driver
- Map in 3rd party modbus-TCP devices
12Heres the Data ...
13Along with the Information ...
14 that leads to the Answer !
15Signature System
- InfoNode Notfication
- Selectable Sources
- Multiple Recipients
- Pager
- E-Mail
- Contact Closure
16Signature System
- InfoNode Notfication
- Interface to 3rd Party Systems
- Building Management
- SCADA
- Human Machine Interface (HMI)?
- Contact Closure E-Mail now
- Future Software links
17Signature System
DataNodes
- 3 Models presently available
- Enhanced Power Quality (EPQ)?
- Power Flow Energy
- 7100 Legacy
- Choose the DataNode that is appropriate for the
application. - DualNode
- Combined EPQ DataNode/InfoNode
- Physical Measurements
- Option to InfoNode and DualNode
18Signature System
Enhanced Power Quality (EPQ) DataNode
- Next Generation of PQ Monitoring
- 4 V 4 I RMS and Transients
- 600VAC, 5A CT Secondary
- 1/2 Cycle RMS
- IEC Harmonics, Interharmonics
- Up to 16 pre/post cycle capture
- Ethernet Communications to InfoNode
- CE, UL
19Signature System
EPQ Triggering Mechanisms
- Voltage Current
- 1/2 Cycle RMS
- Voltage Current transients
- Waveshape
- Harmonics
- Power W, VA, VAR, PF. Forward Reverse
- Symmetrical Components
- Positive, Negative, Zero Sequence
- Per IEC Std.
20Signature System
Enhanced Power Quality (EPQ) DataNode
- 3 Versions
- 5530T External voltage current pods, screw
terminals for circuit connections - 5520T Screw terminals on instrument
- 5513T Safety connectors similar to the PX5.
Clamp-on CTs - Differences are...
- How they connect to the circuit
- Otherwise the same
21Signature System
EPQ DataNode Applications
- Applications requiring Power Quality Analysis
- Demand/Energy PQ
- Mission Critical
- Internet
- Utility
- More ...
22Signature System
EPQ Models 5530T, /TR, /BNC
EPQ Model 5520
23Signature System
Ethernet RJ-45 Normal Cross
COM 1 Administration
AUI
On/Off
(Model 5520)?
Fuses
Power Cord
Current (4)? Terminals
Voltage (4)? Terminals
24Signature System
EPQ Model 5530T
- Voltage Current connections via pods (see next
slide)? - Voltage Pods (new design, May 2002)
- 4 Channels A, B, C, Neutral.
- Differential inputs (ch, ch-).
- Each channel can have a separately derived
reference. - Direct Delta connections A-B, B-C, C-A.
- DC Coupled, can measure DC
- Safe termination at pod allows removal of
instrument - Current pods
- 4 Channels A, B, C, Neutral.
- Inductively measure 5A or 1A secondaries.
- CTs safely terminated at pod to allow removal of
instrument -
25Signature System
EPQ Model 5530T Pods
Voltage Pod
Current Pod
26Signature System
EPQ Model 5530T/TR, 5530T/BNC
- Voltage connections via pods
- Current cable adapter to CTs
- 5530T/TR 4300 TR type CTs
- 5530T/BNC LEMFlex or DC CTs
- Cable adapters in place in current pod
- AC or DC CTs.
27Signature System
EPQ Models 5530T, /TR, /BNC
- Options
- ANSI C12.1 Revenue Calibration
- 1A current pod (5530T)?
- Mounting Brackets
- Horizontal, vertical, rack
- NEMA enclosures.
28Signature System
EPQ Model 5520
- Voltage Current Connections Via Screw Terminals
On Rear Panel - Cycle by Cycle RMS, Harmonics standard
- Options
- Transients Optional (T Version) (Not field
installable)? - ANSI C12.1 Revenue Calibration
- Mounting Brackets (same as InfoNode and 5530T)?
- Misc. Cabling Adapters
29Signature System
EPQ Model 5520
30Signature System
DualNode
31Signature System
DualNode
- Combined 5502 and EPQ DataNode
- 5590T External Voltage Current pods
- 5592T Screw terminals on instrument
- 5593T Safety connectors (like PX5). Clamp-on
CTs - Same InfoNode options as 5502
- Expanded Memory, modem, Answer Modules, etc.
- Add more DataNodes. Same capacity of 5502
- Complete portable monitoring instrument
- Requires no PC software.
32Signature System
DualNode
- Applications
- Single PQ point application
- Starter for a small system
- Service entrance monitoring
- Utility key account monitoring
- Portable or transportable monitoring
- More memory than 4300
- Remote communications (Ethernet or modem)
33Signature System
DualNode Model 5593T
34DataNode Series 5540
Signature System
- 32 Demand Energy type Parameters
- Local Display
- Bright 3 Line LED
- Panel Mount
- Screw Terminals Voltage
- Feed through for Current
- 2 wire RS485 Coms
- Ethernet available using external adapters
35DataNode Series 5540
Signature System
36DataNode Series 5540
Signature System
- Ethernet communications optional
- 4 Versions, Differences are
- Operating Voltage
- CT secondary
- Model 5546 5A, 115VAC
- Model 5547 5A, 230VAC
- model 5548 1A, 115VAC
- Model 5549 1A, 230VAC
37Signature System
DataNode Series 5540 Applications
- Remote Demand/Energy Usage
- Cost Allocations
- Power Curtailment
- Power Cost Determination
- Sub metering
38Signature System
39Signature System
Enterprise SW on PC
(Optional)?
Network LAN, WAN, Internet Ethernet, Fiber,
Wireless, etc.
Modem link
InfoNode
InfoNode
DataNode
DataNode
DataNode
DataNode
DataNode
40Enterprise Software, Why?
Signature System
- Small Systems
- Archive Data View later
- Historical viewing
- Compare to portable data
- Large System
- Archive Data View Later
- Aggregation of Data
- Larger System Integration
- With D-BM or other systems
41Signature System
DranView/Electrotek Services
System Analysis Management Tools
Data Downloader
NodeLink PQView
InfoNode
Webserver
Data Acquisition
DataNode
42Enterprise PC Tools
Signature System
- Downloaders
- NodeLink
- PQView
- Visualization
- DranView 5.0
- PQVIEW, etc...
- Electrotek customization services
43NodeLink
Signature System
- Like DranLink for Signature System
- Automatic or Manual Downloads
- Autopoll download schedule
- InfoNode still primary User Interface
- PQDIF File Format
- View Data in
- DranView 5.0
- PQVIEW, Other ETK
44PQView
Signature System
- Download InfoNodes New Feature!
- Automatic or manual downloading
- View event or trended data
- Advanced data analysis
- Aggregation
- Supports very large systems and databases
- Data Manager supports many instruments from
Dranetz-BMI and other manufacturers
45DranView 5.0
Signature System
- Reads PQDIF Files saved by NodeLink
- View Archived Data
- Advanced Analysis
- Compare Signature data with Portables
46Dranetz-BMI Software
Signature System
Web Browser
Key
InfoNode
Communications
Instrumentation
Visualization
DataBase
5540
5571
EPQ
47Dranetz-BMI Software
DV 5.0
Enterprise Software
PQDIF Files
Signature System
PQVIEW DB
PQVIEW
NodeLink
Web Browser
New Feature! PQView InfoNode Downloads
Key
InfoNode
Communications
Instrumentation
Visualization
DataBase
5540
5571
EPQ
48Dranetz-BMI Software
Existing Products
Existing Systems
4300
3100
PES DB
DV 5.0
PES
PP1
7100
658
90x0
4400/PX5
80x0
PQDIF Files
Signature System
PQVIEW DB
PASS
PQVIEW
NodeLink
Web Browser
Key
InfoNode
Communications
Instrumentation
Visualization
DataBase
5540
5571
EPQ
49Signature System
50ADAM DataNodes
Signature System
- Adds physical measurement capabilities to
Signature System - Correlate physical parameters to power
- Analog - Ex Temperature, pressure, RPM
- Digital - Ex Breaker position, 3rd party alarms
- Correlate various utilities within one system
- Electricity, water, gas, waste water, etc via
pulse counting - Uses Advantech ADAM Data Acquisition and
Control Modules - Many types available and supported by the
InfoNode
51ADAM DataNodes
Signature System
- How does it work?
- RS485 modbus interface from InfoNode to one or
more ADAM modules - Similar to 5540
- Polling rate of about 1 2 seconds
- At setup desired ADAM module type is selected
- Each channel is labeled and given a parameter
type, unit of measurement, and scale - Trended triggered like any parameter
52ADAM DataNodes
Signature System
- Support for ADAM Module Series 4000 5000
- ADAM 4000 Series Remote DAC Modules
- RS485 Daisy chained devices
- Supports multiple modules of different types
- ADAM 5000 Series Distributed DAC
- Back plane for plug in modules
- Supports multiple plug in modules of different
types - RS485 to InfoNode
53ADAM DataNodes
Signature System
ADAM 5000 Series
ADAM 4000 Series
54Generic Modbus Driver New!
Signature System
- Answer Module that allows users to map 3rd party
instruments into the InfoNode - Applicable to Modbus-RTU devices
- User maps device variables into the InfoNode
- Works like the ADAM interface but provides custom
mapping - Parameters are assigned labels, scaling, etc upon
setup.
55GE KV Meter
Signature System
- Provides InfoNode support for GE KV utility meter
- Developed for our DG business
- RS232 or RS485 Interface to InfoNode
- In parallel with other DataNodes
56GE KV Meter
Signature System
- Parameters provided
- V, I, W, PF, VA, VAR, more
- 5540 like parameters but in a meter socket
- Polled at a rate of 1 2 seconds
- Various mounting sockets and PT/CTs
57GE KV Meter
Signature System
- Why would I use it?
- Utilize existing KV Meter data by incorporating
as a DataNode into Signature System - Best utilization of existing assets by
incorporating existing metering in parallel
with PQ of other DataNode - Where a socket type meter is required along
with PQ provided by other DataNodes - Where there is a need for remote web access to
the GE meter