System Details - PowerPoint PPT Presentation

1 / 57
About This Presentation
Title:

System Details

Description:

Signature System that evolves with your needs. InfoNode ... (hard disk vs. compact flash ) ... Compact Flash (CF) memory Technology. 32M standard, 64M ... – PowerPoint PPT presentation

Number of Views:54
Avg rating:3.0/5.0
Slides: 58
Provided by: tequi
Category:

less

Transcript and Presenter's Notes

Title: System Details


1
Signature System
  • System Details

2
The Concept - from a small system
DataNode
DataNode
InfoNode
DataNode
DataNode
DataNode
3
The Concept - to the enterprise level
DataNode
DataNode
InfoNode
DataNode
DataNode
DataNode
NodeLink
InfoNode
InfoNode
DataNode
DataNode
DataNode
DataNode
4
Signature System that evolves with your needs
5
InfoNode
Signature System
  • Industrial computer or
  • PC Based Web Server

6
Signature System
  • InfoNode System Gateway
  • What is an InfoNode?
  • Data concentrator and web server.
  • Collects data from all monitoring instruments and
    stored into a database
  • Built-in Web server compatible with IE, Netscape,
    Modzilla, etc.
  • All user interactions are via a web browser via
    any computer on the network.
  • Browse the InfoNode database. Trends, event
    lists, real time, system setup
  • Available in 2 varieties
  • Reliable industrial computer. Hard disk or CF
    based
  • PC software
  • Choose whats appropriate for your application

7
Signature System
  • InfoNode Series 5500 Industrial Computer
  • 2 Models 5502 5504
  • Differences are
  • Memory Technology (hard disk vs. compact flash )?
  • Temperature Range (based upon memory technology)?
  • Common Options
  • Answer Modules
  • GPS
  • Modem
  • Mounting Brackets
  • Misc. Cables Adapters
  • DataNode Drivers

8
Signature System
  • InfoNode Model 5502
  • Compact Flash (CF) memory Technology
  • 32M standard, 64M 128M Optional
  • Extended Temperature Range
  • 0 - 65 C
  • CE, UL
  • Supports up to 5 DataNodes (with expanded
    memory)?
  • Actual number depends on Datanode type and of
    parameters recorded
  • When to use
  • Where a turn-key, drop-in solution is required.
    No software to install
  • Harsh environments. CF is more tolerant than a
    hard disk.
  • Applicable for small systems that will not grow
    larger than 5 Datanodes
  • Hacking and virus protection is a concern. Not
    Windows based, not a target

9
Signature System
  • InfoNode Model 5504
  • Hard Disk Memory Technology
  • 2G DataBase
  • Temperature Range
  • 10 - 50 C
  • CE, UL
  • Supports up to 20 DataNodes
  • Actual number depends on Datanode type and of
    param.recorded
  • When to use
  • Where a turn-key, drop-in solution is required.
    No software to install
  • Hacking and virus protection is a concern. Not
    Windows based, not a target
  • Environment is hard disk friendly

10
Signature System
  • PCInfoNode
  • PC Based. Software to convert PC into an InfoNode
  • Functionally the same as a 5502/5504 but runs on
    a PC
  • PC should be a dedicated PCInfoNode
  • Hardware key (USB HASP) software license
  • 8GB database
  • Lower cost (than 5502, 5504) solution.
  • Customer or Dranetz-BMI supplies PC
  • Supports greater than 30 DataNodes.
  • Actual number depends on Datanode type and of
    parameters recorded.
  • Choose PC InfoNode when one or more of the
    following apply
  • Large systems
  • Customer wants PC based solution
  • Lower cost
  • Environment is PC/hard disk friendly

11
Signature System
  • InfoNode Answer Modules
  • Cap Bank Switch
  • Was that Transient a Cap switch? Was it upstream
    or downstream
  • VAR Verifier add-on. Did the cap switch in
    properly. Delta VARS OK.
  • Sag Directivity
  • Did that Sag originate at the source or load
  • Distance to Radial Line Fault
  • What is the distance from the monitoring point to
    the fault
  • Energy Usage Management
  • Energy reporting, aggregation and allocation
  • UPS Verification
  • UPS I/O correlation reports
  • OneLine
  • Custom facility one line with real time
    monitoring points overlaid
  • Generic Modbus Driver
  • Map in 3rd party modbus-TCP devices

12
Heres the Data ...
13
Along with the Information ...
14
that leads to the Answer !
15
Signature System
  • InfoNode Notfication
  • Selectable Sources
  • Multiple Recipients
  • Pager
  • E-Mail
  • Contact Closure

16
Signature System
  • InfoNode Notfication
  • Interface to 3rd Party Systems
  • Building Management
  • SCADA
  • Human Machine Interface (HMI)?
  • Contact Closure E-Mail now
  • Future Software links

17
Signature System
DataNodes
  • 3 Models presently available
  • Enhanced Power Quality (EPQ)?
  • Power Flow Energy
  • 7100 Legacy
  • Choose the DataNode that is appropriate for the
    application.
  • DualNode
  • Combined EPQ DataNode/InfoNode
  • Physical Measurements
  • Option to InfoNode and DualNode

18
Signature System
Enhanced Power Quality (EPQ) DataNode
  • Next Generation of PQ Monitoring
  • 4 V 4 I RMS and Transients
  • 600VAC, 5A CT Secondary
  • 1/2 Cycle RMS
  • IEC Harmonics, Interharmonics
  • Up to 16 pre/post cycle capture
  • Ethernet Communications to InfoNode
  • CE, UL

19
Signature System
EPQ Triggering Mechanisms
  • Voltage Current
  • 1/2 Cycle RMS
  • Voltage Current transients
  • Waveshape
  • Harmonics
  • Power W, VA, VAR, PF. Forward Reverse
  • Symmetrical Components
  • Positive, Negative, Zero Sequence
  • Per IEC Std.

20
Signature System
Enhanced Power Quality (EPQ) DataNode
  • 3 Versions
  • 5530T External voltage current pods, screw
    terminals for circuit connections
  • 5520T Screw terminals on instrument
  • 5513T Safety connectors similar to the PX5.
    Clamp-on CTs
  • Differences are...
  • How they connect to the circuit
  • Otherwise the same

21
Signature System
EPQ DataNode Applications
  • Applications requiring Power Quality Analysis
  • Demand/Energy PQ
  • Mission Critical
  • Internet
  • Utility
  • More ...

22
Signature System
EPQ Models 5530T, /TR, /BNC
EPQ Model 5520
23
Signature System
Ethernet RJ-45 Normal Cross
COM 1 Administration
AUI
On/Off
(Model 5520)?
Fuses
Power Cord
Current (4)? Terminals
Voltage (4)? Terminals
24
Signature System
EPQ Model 5530T
  • Voltage Current connections via pods (see next
    slide)?
  • Voltage Pods (new design, May 2002)
  • 4 Channels A, B, C, Neutral.
  • Differential inputs (ch, ch-).
  • Each channel can have a separately derived
    reference.
  • Direct Delta connections A-B, B-C, C-A.
  • DC Coupled, can measure DC
  • Safe termination at pod allows removal of
    instrument
  • Current pods
  • 4 Channels A, B, C, Neutral.
  • Inductively measure 5A or 1A secondaries.
  • CTs safely terminated at pod to allow removal of
    instrument

25
Signature System
EPQ Model 5530T Pods
Voltage Pod
Current Pod
26
Signature System
EPQ Model 5530T/TR, 5530T/BNC
  • Voltage connections via pods
  • Current cable adapter to CTs
  • 5530T/TR 4300 TR type CTs
  • 5530T/BNC LEMFlex or DC CTs
  • Cable adapters in place in current pod
  • AC or DC CTs.

27
Signature System
EPQ Models 5530T, /TR, /BNC
  • Options
  • ANSI C12.1 Revenue Calibration
  • 1A current pod (5530T)?
  • Mounting Brackets
  • Horizontal, vertical, rack
  • NEMA enclosures.

28
Signature System
EPQ Model 5520
  • Voltage Current Connections Via Screw Terminals
    On Rear Panel
  • Cycle by Cycle RMS, Harmonics standard
  • Options
  • Transients Optional (T Version) (Not field
    installable)?
  • ANSI C12.1 Revenue Calibration
  • Mounting Brackets (same as InfoNode and 5530T)?
  • Misc. Cabling Adapters

29
Signature System
EPQ Model 5520
30
Signature System
DualNode
31
Signature System
DualNode
  • Combined 5502 and EPQ DataNode
  • 5590T External Voltage Current pods
  • 5592T Screw terminals on instrument
  • 5593T Safety connectors (like PX5). Clamp-on
    CTs
  • Same InfoNode options as 5502
  • Expanded Memory, modem, Answer Modules, etc.
  • Add more DataNodes. Same capacity of 5502
  • Complete portable monitoring instrument
  • Requires no PC software.

32
Signature System
DualNode
  • Applications
  • Single PQ point application
  • Starter for a small system
  • Service entrance monitoring
  • Utility key account monitoring
  • Portable or transportable monitoring
  • More memory than 4300
  • Remote communications (Ethernet or modem)

33
Signature System
DualNode Model 5593T
34
DataNode Series 5540
Signature System
  • 32 Demand Energy type Parameters
  • Local Display
  • Bright 3 Line LED
  • Panel Mount
  • Screw Terminals Voltage
  • Feed through for Current
  • 2 wire RS485 Coms
  • Ethernet available using external adapters

35
DataNode Series 5540
Signature System
36
DataNode Series 5540
Signature System
  • Ethernet communications optional
  • 4 Versions, Differences are
  • Operating Voltage
  • CT secondary
  • Model 5546 5A, 115VAC
  • Model 5547 5A, 230VAC
  • model 5548 1A, 115VAC
  • Model 5549 1A, 230VAC

37
Signature System
DataNode Series 5540 Applications
  • Remote Demand/Energy Usage
  • Cost Allocations
  • Power Curtailment
  • Power Cost Determination
  • Sub metering

38
Signature System
  • Enterprise Software

39
Signature System
Enterprise SW on PC
(Optional)?
Network LAN, WAN, Internet Ethernet, Fiber,
Wireless, etc.
Modem link
InfoNode
InfoNode
DataNode
DataNode
DataNode
DataNode
DataNode
40
Enterprise Software, Why?
Signature System
  • Small Systems
  • Archive Data View later
  • Historical viewing
  • Compare to portable data
  • Large System
  • Archive Data View Later
  • Aggregation of Data
  • Larger System Integration
  • With D-BM or other systems

41
Signature System
DranView/Electrotek Services
System Analysis Management Tools
Data Downloader
NodeLink PQView
InfoNode
Webserver
Data Acquisition
DataNode
42
Enterprise PC Tools
Signature System
  • Downloaders
  • NodeLink
  • PQView
  • Visualization
  • DranView 5.0
  • PQVIEW, etc...
  • Electrotek customization services

43
NodeLink
Signature System
  • Like DranLink for Signature System
  • Automatic or Manual Downloads
  • Autopoll download schedule
  • InfoNode still primary User Interface
  • PQDIF File Format
  • View Data in
  • DranView 5.0
  • PQVIEW, Other ETK

44
PQView
Signature System
  • Download InfoNodes New Feature!
  • Automatic or manual downloading
  • View event or trended data
  • Advanced data analysis
  • Aggregation
  • Supports very large systems and databases
  • Data Manager supports many instruments from
    Dranetz-BMI and other manufacturers

45
DranView 5.0
Signature System
  • Reads PQDIF Files saved by NodeLink
  • View Archived Data
  • Advanced Analysis
  • Compare Signature data with Portables

46
Dranetz-BMI Software
Signature System
Web Browser
Key
InfoNode
Communications
Instrumentation
Visualization
DataBase
5540
5571
EPQ
47
Dranetz-BMI Software
DV 5.0
Enterprise Software
PQDIF Files
Signature System
PQVIEW DB
PQVIEW
NodeLink
Web Browser
New Feature! PQView InfoNode Downloads
Key
InfoNode
Communications
Instrumentation
Visualization
DataBase
5540
5571
EPQ
48
Dranetz-BMI Software
Existing Products
Existing Systems
4300
3100
PES DB
DV 5.0
PES
PP1
7100
658
90x0
4400/PX5
80x0
PQDIF Files
Signature System
PQVIEW DB
PASS
PQVIEW
NodeLink
Web Browser
Key
InfoNode
Communications
Instrumentation
Visualization
DataBase
5540
5571
EPQ
49
Signature System
  • 3rd Party DataNodes

50
ADAM DataNodes
Signature System
  • Adds physical measurement capabilities to
    Signature System
  • Correlate physical parameters to power
  • Analog - Ex Temperature, pressure, RPM
  • Digital - Ex Breaker position, 3rd party alarms
  • Correlate various utilities within one system
  • Electricity, water, gas, waste water, etc via
    pulse counting
  • Uses Advantech ADAM Data Acquisition and
    Control Modules
  • Many types available and supported by the
    InfoNode

51
ADAM DataNodes
Signature System
  • How does it work?
  • RS485 modbus interface from InfoNode to one or
    more ADAM modules
  • Similar to 5540
  • Polling rate of about 1 2 seconds
  • At setup desired ADAM module type is selected
  • Each channel is labeled and given a parameter
    type, unit of measurement, and scale
  • Trended triggered like any parameter

52
ADAM DataNodes
Signature System
  • Support for ADAM Module Series 4000 5000
  • ADAM 4000 Series Remote DAC Modules
  • RS485 Daisy chained devices
  • Supports multiple modules of different types
  • ADAM 5000 Series Distributed DAC
  • Back plane for plug in modules
  • Supports multiple plug in modules of different
    types
  • RS485 to InfoNode

53
ADAM DataNodes
Signature System
ADAM 5000 Series
ADAM 4000 Series
54
Generic Modbus Driver New!
Signature System
  • Answer Module that allows users to map 3rd party
    instruments into the InfoNode
  • Applicable to Modbus-RTU devices
  • User maps device variables into the InfoNode
  • Works like the ADAM interface but provides custom
    mapping
  • Parameters are assigned labels, scaling, etc upon
    setup.

55
GE KV Meter
Signature System
  • Provides InfoNode support for GE KV utility meter
  • Developed for our DG business
  • RS232 or RS485 Interface to InfoNode
  • In parallel with other DataNodes

56
GE KV Meter
Signature System
  • Parameters provided
  • V, I, W, PF, VA, VAR, more
  • 5540 like parameters but in a meter socket
  • Polled at a rate of 1 2 seconds
  • Various mounting sockets and PT/CTs

57
GE KV Meter
Signature System
  • Why would I use it?
  • Utilize existing KV Meter data by incorporating
    as a DataNode into Signature System
  • Best utilization of existing assets by
    incorporating existing metering in parallel
    with PQ of other DataNode
  • Where a socket type meter is required along
    with PQ provided by other DataNodes
  • Where there is a need for remote web access to
    the GE meter
Write a Comment
User Comments (0)
About PowerShow.com