Ethernet Cables - PowerPoint PPT Presentation

1 / 47
About This Presentation
Title:

Ethernet Cables

Description:

The twisted-pair or fiber-optic media connecting workstations and wiring closets ... The additional closets are called intermediate distribution facilities (IDFs) ... – PowerPoint PPT presentation

Number of Views:351
Avg rating:3.0/5.0
Slides: 48
Provided by: garybr4
Category:

less

Transcript and Presenter's Notes

Title: Ethernet Cables


1
Ethernet Cables
R
R
Sw
Straight-Through
Cross-Over
PC
PC
2
Twisted-Pair Cabling
  • Common traits of all twisted-pair cabling types
    and categories
  • The wires are copper
  • The wires come in pairs
  • The pairs of wires are twisted around each other
  • The pairs of wires are usually enclosed in a
    cable sheath individually and as a group of wires

3
Twisted-Pair Cabling
  • Crosstalk
  • Signal bleed from one cable to another
  • Usually occurs in poorly wired media
  • Cancellation
  • Insulates the signal from the effects of signal
    bleeding

4
Unshielded Twisted-Pair (UTP)
  • Cabling used for a variety of electronic
    communications

CAT 5e Designed to correct shortcomings of CAT
5, particularly for Gigabit Ethernet and
full-duplex operation. Signaling rate 100MHz
like CAT 5. CAT 6 Recommended cabling for
Ethernet over copper at speeds up to 1 Gigabit.
Signaling rate up to 200MHz.
5
Unshielded Twisted-Pair (UTP)
  • UTP advantages
  • Thin flexible cable that is easy to string
    between walls
  • Most modern buildings come with CAT 5e or CAT 6
    UTP already wired into the wall outlets or at
    least run between the floors
  • Because UTP is small, it does not quickly fill up
    wiring ducts
  • Costs less per foot than other type of LAN cable

6
Unshielded Twisted-Pair (UTP)
  • UTP disadvantages
  • Somewhat susceptible to interference
  • Pair twisting does help, but it does not make the
    cable impervious to electrical noise
  • Its unrepeated length limit is 100 meters

7
RJ-45 Connectors
  • Registered Jacks (RJ)
  • Type of telecommunication connector used for
    twisted-pair cabling
  • Typically RJ-45 connectors resemble the typical
    RJ-11 connectors that connect the phone to the
    wall
  • Difference between RJ-45 connectors and RJ-11
    connectors is that the former has eight wires
    (four-pair) and the latter four (two-pair)
  • Some RJ-11 connectors are used with three-pair
    (six-wire) UTP

8
Terminology
  • The RJ-45 jack is the receptacle
  • And the RJ-45 plug is the connector at the end of
    the patch cable

9
Horizontal Cabling Standards
  • Horizontal cabling
  • The twisted-pair or fiber-optic media connecting
    workstations and wiring closets
  • Electronics Industries Alliance and
    Telecommunications Industry Association (EIA/TIA)
  • Define a set of specifications which covers
    outlets near the workstation, mechanical
    terminations in wiring closets, and all cable
    running along the horizontal path between wiring
    closet and workstation (EIA/TIA 568A cabling
    standards, EIA/TIA 569 pathways and spaces)

10
Horizontal Cabling Standards
11
Horizontal Cabling Standards
  • EIA/TIA-568A
  • Specifies that the maximum distance for a UTP
    horizontal cable run is 90 meters (295 feet)
  • Total of 10 meters is allowed for patch cables
    (a.k.a. patch cords)
  • In addition to UTP, the following cable types may
    be used for horizontal pathways
  • STP Shielded Twisted Pair
  • Fiber-optic

12
Wiring Closets
  • Contain the wiring and wiring equipment for
    connecting network devices, such as routers,
    switches, patch panels, and hubs
  • EIA/TIA-568 and EIA/TIA-569 standards apply to
    the physical layout of media and wiring closets,
    with the latter stating there must be a minimum
    of one wiring closet per floor
  • Furthermore, when a given floor area (catchment
    area) exceeds 1,000 square meters, or the
    horizontal cabling more than 90 meters,
    additional wiring closets are needed

13
Wiring Closets
  • The main distribution facility (MDF) is the
    central junction point for wiring of a star
    topology
  • The additional closets are called intermediate
    distribution facilities (IDFs)
  • IDFs are required when
  • Catchment area of MDF is not large enough to
    capture all nodes
  • The LAN is in a multistory facility
  • The LAN encompasses multiple buildings

14
Proximity to the POP
  • Ensure that main wiring closet is close to the
    point of presence (POP) to a wider network, e.g.,
    to the Internet.

Network spanning multiple buildings
15
Proximity to the POP
Network spanning multiple floors
16
Backbone
  • Backbone cable (sometimes called vertical
    cabling) connects wiring closets to each other in
    an extended star topology
  • EIA/TIA-568A specifies four different options for
    backbone cabling
  • 100-ohm UTP
  • 150-ohm STP
  • 62.5/125-micron optical fiber (multi-mode)
  • Single-mode optical fiber

17
Installing Connectors
RJ-45 connector
18
Installing Connectors
UTP wires
19
Installing Connectors
Jack wiring (T568B)
20
Installing Connectors
  • EIA/TIA-T568B
  • Wiring method used to indicate which colors are
    assigned to which pin for UTP cable
  • T568A is sometimes used (different color
    termination sequence)
  • Punch tool
  • Used to punch down cable at the patch panel or
    wall plate
  • Crimp tool
  • Used to terminate RJ-45 plug on cable

21
Patch Panel
Patch panel (back) pins
22
Patch Panel Punch Tool
Patch panel ports
Punch tool used to terminate horizontal cable at
back of patch panel
23
Crimp Tool
Used to attach plug to patch cable
24
Color Scheme
  • Association of pair number with color
  • Originally used by the telephone industry
  • Pair 1 - White with blue strips (W-Bl)
  • Blue with white strips (Bl)
  • Pair 2 - White with orange strips (W-O)
  • Orange with white strips (O)
  • Pair 3 - White with green strips (W-G)
  • Green with white strips (G)
  • Pair 4 - White with brown strips (W-Br)
  • Brown with white strips (Br)

25
Termination Sequence
  • EIA/TIA
  • T568B termination standard
  • Most widely used for data communication
  • Defines the order in which incoming pairs are
    terminated into plug pins

26
T568B Standard
  • Each end wired the same, i.e., straight through
  • Plug receptacle end with locking tab at bottom
  • Yellow pairs/pins used for 10BaseT 100BaseT

27
Cross-Over Cable
  • Also called an uplink cable
  • Cross transmit and receive at one end
  • That is, use T568A at one end T568B at other

28
Cross-Over Cable
29
Straight-Through Cross-Over
Standard Cross-Over
30
Pin Numbers
Locking tab on back
31
Making Patch Cable
  • Cut a about 1½ to 2 of cable off the roll, or
    cut the plugs off an old cable.
  • Cut about 2 of the jacket from the end.
  • Cut away the ripcord and discard it.
  • Untwist the pairs and arrange them in the T568B
    color sequence.
  • Cut all eight wires squarely ½
  • from the jacket with the wire
  • cutter.

32
Making Patch Cable
All the way to end
  • Insert wires into the plug and push them all the
    way to the end.
  • Insert the plug into the crimping tool. Press
    the handles together firmly. Remove plug from
    tool.

33
Making Patch Cable
  • Inspect plug to be sure the termination is
    correct
  • Conductors should all be touching the end of the
    plug.
  • All 8 pins should be fully depressed.
  • The pins feet should be fully inserted into the
    wire.
  • The flange should be fully
  • depressed against the jacket,
  • and the end of the jacket should
  • be beyond the flange.

34
Cable Testers Wire Map
  • Important measurement a cable tester makes to
    check wiring sequence

Wire map error detection
35
Cable Testers Wire Map
Crossed pairs
Split pairs
36
Cable Testers Attenuation
  • Attenuation is the loss of signal power over the
    distance of a cable
  • Signal injector
  • Puts traffic on a wire so that a cable tester can
    measure attenuation and crosstalk
  • The lower the attenuation, the better

37
Cable Testers Noise
  • Alternating current (AC) signal noises are called
    oscillations and can alter the digital signals
    that computers receive on the wire
  • The motherboard and other internal integrated
    circuits of a computer use the chassis as their
    ground
  • Faulty AC wiring can also cause problems with
    transmissions because the signal reference ground
    is the computer chassis and grounding plate

38
Cable Testers NEXT
  • Near end crosstalk (NEXT)
  • Measure of interference from other wire pairs
  • Causes of NEXT include
  • Split pairs
  • Too much wire untwisted at the patch panel, jack,
    or connectors
  • Bends, kinks, or stretches in the cabling

39
Cable Testers NEXT
NEXT test on a cable analyzer
40
Cable Testers Distance Measure
  • EIA/TIA-568A specifies maximum cable lengths for
    network media
  • Cables that are too long can cause delays in
    transmission and network errors
  • Time-domain reflectometer (TDR)
  • Cable tester that can detect the overall length
    of a cable or the distance to a cable break

41
Three-Layer Network Model
  • Divides a network into three connectivity layers
  • Consists of
  • Core layer
  • WAN technology to interconnect sites
  • Forms the higher-level backbone
  • Distribution layer
  • Backbone network used to interconnect buildings
  • Forms the campus network
  • Access layer
  • LAN or group of LANs providing connectivity for
    end-stations (servers, workstations, printers)
  • Technology closest to users

42
Three-Layer Network Model
Three-layer hierarchical network model
43
Two One-Layer Network Models
  • Two-layer network model
  • Divides a network into two connectivity layers
  • Core
  • Access
  • One-layer network model
  • Smaller networks
  • Includes WAN connectivity equipment and LAN
    connectivity equipment in same layer
  • May be adapted to the two-layer and three-layer
    design models in the future
  • Note that the difference between the three models
    is the number of levels of routers

44
Two-Layer Network Model
Two-layer hierarchical network model
45
One-Layer Network Model
One-layer network model
46
Summary
  • UTP cabling
  • Nomenclature EIA/TIA, wiring closet, MDF, IDF,
    POP, horizontal cable, vertical (backbone) cable
  • Installing connectors
  • Cable testers
  • Network hierarchy models

47
End
Write a Comment