2003 Antarctic Match campaign - PowerPoint PPT Presentation

About This Presentation
Title:

2003 Antarctic Match campaign

Description:

Comparison of Observations During the First Antarctic Match ... SLIMCAT is very consistence with observations between 400-650K but gives too much O3 below 400K ... – PowerPoint PPT presentation

Number of Views:54
Avg rating:3.0/5.0
Slides: 7
Provided by: theenvi
Category:

less

Transcript and Presenter's Notes

Title: 2003 Antarctic Match campaign


1
Comparison of Observations During the First
Antarctic Match Campaign with a 3D CTM W. Feng1,
M.P. Chipperfield1 School of Earth and
Environment, University of Leeds, UK
  • 2003 Antarctic Match campaign
  • June-Oct 2003
  • nine Ozonesonde stations
  • Measure Chemical O3 loss rate
  • SLIMCAT 3D CTM
  • Ozone and loss rate comparison
  • Correction factors

Acknowledgments H.K. Roscoe2, M. Rex3, P. von
der Gathen3, M. Streibel3, F.Goutail4, G.
Konig-Langlo3, T. Deshler5, B. Johnson6, J.
Easson7, M. Yela8, P. Taalas9, K. Sato10
Supported by NERC and SCOUT-O3 project
2
SLIMCAT/TOMCAT 3D CTM
  • Off-line chemical transport model Chipperfield,
    JGR, 1999
  • Extends to surface using hybrid ?-? levels
    (SLIMCAT version). Variable horizontal/vertical
    resolution.
  • Horizontal winds and temperatures from analyses
    (e.g. UKMO, ECMWF (ERA-40 or operational)).
  • Vertical motion from diagnosed heating rates or
    divergence.
  • Tropospheric physics convection, PBL mixing
    etc.
  • Chemistry Full stratospheric chemistry scheme
    (41 species, 160 reactions) with heterogeneous
    chemistry on liquid/solid aerosols/PSCs and an
    equilibrium denitrification scheme.
  • NAT-based denitrification scheme included.
  • http//www.env.leeds.ac.
    uk/slimcat

3
Arctic Ozone loss versus VPSC
New T42 run
Obs
New T15 run
Old T15 run
Chipperfield M.P., W. Feng and M. Rex(GRL, 2005)
SLIMCAT now gives a realistic representation of
ozone and inferred ozone loss for Arctic winters
under different meteorological conditions
4
Comparison with Observation
425K
460K
495K
Good agreement between Ozonesondes measurements
and SLIMCAT
5
Ozone loss rate at 450K
Match
SLIMCAT
CLAMS
FMI
Models reproduce the observed O3 loss rate very
well
Reprobus
6
The Mean and correction factors
Correction factors
Mean ratio
  • SLIMCAT is very consistence with observations
    between 400-650K but gives too much O3 below 400K
  • SLIMCAT can be used as a transfer standard to
    expose systematic differences between
    observations from the different ozonesonde sites
    and can provide corrections between them.
Write a Comment
User Comments (0)
About PowerShow.com