Title:
1IRT
Innovative Remediation Technologies, Inc
The VTX Process
Liquid Incineration for a Cleaner Environment
2IRT
- VTX is an organic catalyst that reacts with
various oxidizing agents to produce hydroxyl
radicals. - No sludge is produced as a result of the process
in normal use. - Safe and easy to apply.
- Application of catalyst requires no materials of
special construction.
3Relative Oxidation Potential
IRT
- Reactive Species Relative Oxidation
Power - Fluorine 2.23
- Hydroxyl radicals 2.06
- Atomic oxygen (singlet) 1.78
- Ozone 1.52
- Persulfate 1.48
- Hydrogen peroxide 1.31
- Permanganate 1.24
- Hypochlorous acid 1.10
- Chlorine 1.00
4Odor Corrosion Control
IRT
5The VTX ProcessTreatment of Sulfide
IRT
- VTX rapidly converts sulfide (H2S, HS-, S) to
elemental sulfur. - Immediate reduction of odor and corrosion due to
H2S. - VTX is suited for control of sulfide in
-
- Landfills
- Food Production
- Animal Waste
- Municipal and Industrial Wastewater Treatment
Rapid Oxidation of Sulfide
6IRT
Reaction Time and Dosage Comparison H2O2 Alone
vs. VTX Process Treatment of Hydrogen Sulfide
Hydrogen Peroxide Alone H2S H2O2 ?
S0 2H2O Reaction time 20-30
minutes Effective dosage (mass H2O2/mass H2S)
1.5 to 4.0 1.0 VTX Process H2S VTX /H2O2 ?
S0 2H2O salts CO2 VTX Reaction time
lt3 minutes Effective Dosage (mass VTX/mass
H2S) 1.5 to 2.5 1.0 Note VTX remaining
un-reacted VTX
7IRT
Comparative Treatment of Sulfides in Wastewater
Hydrogen Peroxide vs. VTX Process
H2O2 only
H2O2 w/ variable VTX dosages
8Corrosion Control
IRT
Melbourne, Florida 3 year old pipe
9IRT
Melbourne, Florida 3 year old pipe
10IRT
N. Brevard, Florida Headworks 7 years old
currently closed for repairs
11Estimated Affect of S on Infrastructure Life
Expectancy
IRT
(3 Diameter Concrete Pipe in Gravity Sewer)
S (ppm) Life Expectancy (Years)
0.5 gt50 1.0
25-50 1.5 25
2.0 10-25 2.5
10 3.0 10
4.0 5-10 7.0
5 gt7.0 lt5 Varies
based on alkalinity and pH scenarios
12Capital and Operational Savings
IRT
- The VTX Catalytic Process can rapidly eliminate
gt95 of the sulfides entering the headworks of a
wastewater plant.
13IRT
14IRT
15York River STPScrubber Influent H2STreatment
initiated _at_ 0645, Stopped _at_ 1445
IRT
16IRT
17IRT
Case Study California Wastewater Treatment Plant
18IRT
Case Study California Wastewater Treatment Plant
19Before and After TreatmentMelbourne, Florida
Lift Station Atmospheric H2S
IRT
20Before and After TreatmentMelbourne, Florida
Lift StationAqueous Sulfide
IRT
21IRT
VTX Sludge Treatment Study Total Sulfide
Destruction Springville, Utah Wastewater
Treatment Plant
VTX Calibration Period
22VTX Facts
IRT
- VTX for treatment of organic and selected
inorganic chemicals is patent pending. - VTX as a disinfectant is also patent pending.
- VTX is EPA TSCA approved for use in the
environment.