- PowerPoint PPT Presentation

1 / 22
About This Presentation
Title:

Description:

... H2O2 Alone vs. VTX Process Treatment of Hydrogen ... Study California Wastewater Treatment Plant Case ... 17 Slide 18 Before and After Treatment ... – PowerPoint PPT presentation

Number of Views:4
Avg rating:3.0/5.0
Slides: 23
Provided by: innrtComw
Category:

less

Transcript and Presenter's Notes

Title:


1
IRT
Innovative Remediation Technologies, Inc
The VTX Process
Liquid Incineration for a Cleaner Environment
2
IRT
  • VTX is an organic catalyst that reacts with
    various oxidizing agents to produce hydroxyl
    radicals.
  • No sludge is produced as a result of the process
    in normal use.
  • Safe and easy to apply.
  • Application of catalyst requires no materials of
    special construction.

3
Relative Oxidation Potential
IRT
  • Reactive Species Relative Oxidation
    Power
  • Fluorine 2.23
  • Hydroxyl radicals 2.06
  • Atomic oxygen (singlet) 1.78
  • Ozone 1.52
  • Persulfate 1.48
  • Hydrogen peroxide 1.31
  • Permanganate 1.24
  • Hypochlorous acid 1.10
  • Chlorine 1.00

4
Odor Corrosion Control
IRT
  • Treatment of Sulfide

5
The VTX ProcessTreatment of Sulfide
IRT
  • VTX rapidly converts sulfide (H2S, HS-, S) to
    elemental sulfur.
  • Immediate reduction of odor and corrosion due to
    H2S.
  • VTX is suited for control of sulfide in
  • Landfills
  • Food Production
  • Animal Waste
  • Municipal and Industrial Wastewater Treatment

Rapid Oxidation of Sulfide
6
IRT
Reaction Time and Dosage Comparison H2O2 Alone
vs. VTX Process Treatment of Hydrogen Sulfide
Hydrogen Peroxide Alone H2S H2O2 ?
S0 2H2O Reaction time 20-30
minutes Effective dosage (mass H2O2/mass H2S)
1.5 to 4.0 1.0 VTX Process H2S VTX /H2O2 ?
S0 2H2O salts CO2 VTX Reaction time
lt3 minutes Effective Dosage (mass VTX/mass
H2S) 1.5 to 2.5 1.0 Note VTX remaining
un-reacted VTX
7
IRT
Comparative Treatment of Sulfides in Wastewater
Hydrogen Peroxide vs. VTX Process
H2O2 only
H2O2 w/ variable VTX dosages
8
Corrosion Control
IRT
Melbourne, Florida 3 year old pipe
9
IRT
Melbourne, Florida 3 year old pipe
10
IRT
N. Brevard, Florida Headworks 7 years old
currently closed for repairs
11
Estimated Affect of S on Infrastructure Life
Expectancy
IRT
(3 Diameter Concrete Pipe in Gravity Sewer)
S (ppm) Life Expectancy (Years)
0.5 gt50 1.0
25-50 1.5 25
2.0 10-25 2.5
10 3.0 10
4.0 5-10 7.0
5 gt7.0 lt5 Varies
based on alkalinity and pH scenarios
12
Capital and Operational Savings
IRT
  • The VTX Catalytic Process can rapidly eliminate
    gt95 of the sulfides entering the headworks of a
    wastewater plant.

13
IRT
14
IRT
15
York River STPScrubber Influent H2STreatment
initiated _at_ 0645, Stopped _at_ 1445
IRT
16
IRT
17
IRT
Case Study California Wastewater Treatment Plant
18
IRT
Case Study California Wastewater Treatment Plant
19
Before and After TreatmentMelbourne, Florida
Lift Station Atmospheric H2S
IRT
20
Before and After TreatmentMelbourne, Florida
Lift StationAqueous Sulfide
IRT
21
IRT
VTX Sludge Treatment Study Total Sulfide
Destruction Springville, Utah Wastewater
Treatment Plant
VTX Calibration Period
22
VTX Facts
IRT
  • VTX for treatment of organic and selected
    inorganic chemicals is patent pending.
  • VTX as a disinfectant is also patent pending.
  • VTX is EPA TSCA approved for use in the
    environment.