Title: Infrared Thermography
1Infrared Thermography
A Guide For Establishing a Predictive Maintenance
Program
2How can infrared thermography impact your bottom
line?
- Evaluate equipment reliably, efficiently, and
without disruption to operations. - Ensure uninterrupted power.
- Avoid costly failures and shutdowns.
- Postpone previously scheduled maintenance of
equipment found to be in good condition. - Verify new equipment installations to establish a
baseline for future inspections.
3How can infrared thermography impact your bottom
line?
In many cases, the savings in insurance claims
due to predicted equipment failure have pushed
insurance companies to obligate their clients to
perform regular infrared inspections as a term of
their policy renewal. Many studies have shown
that the financial and safety benefits to
industrial and commercial facilities far outweigh
the costs of implementing and maintaining an
effective PdM program.
4What is Infrared Thermography?
What is Infrared Thermography?
Heat is referred to as the transfer of
electromagnetic energy, in the infrared band,
through either conduction, convection, or
radiation between two or more substances. The
measurement of the transfer of this infrared
energy is called temperature. There is no heat
or temperature without this energy transfer.
Infrared energy is invisible to the human eye but
can be felt , sensed, and measured.
5What is Infrared Thermography?
The infrared camera evaluates and converts heat
energy into meaningful temperatures. Components
in various states of failure will emit more heat
as a direct result of more energy dissipated into
the component. This extra energy is caused by
increased friction in mechanical devices, and
higher resistance in electrical devices.
6Why use infrared thermography?
Why Use Infrared Thermography?
- Just as doctors use temperature in disease
diagnosis, infrared thermography allows us to
diagnose and pinpoint problems based on the
temperature differential of areas. Temperature
provides an excellent indication of the condition
of equipment. - It is the ability of the thermal camera to "see"
these early stages of increasing temperature that
makes thermography such a valuable technology.
7Why use Delmarva Infrared Services?
8Why use Delmarva Infrared Services?
- We use a state-of-the-art database and barcode
system which allows accurate equipment tracking
and maintenance records as well as a tool for PdM
scheduling and maintenance priorities. - Field experience with not only the infrared
equipment, but also hands on experience with
electrical, HVAC and industrial equipment,
allowing not only the discovery of problems, but
accurate interpretation of exact problems, so
they can be corrected quickly and efficiently.
9What kind of equipment will be used to perform
the inspection?
- Delmarva Infrared Services uses an extremely
lightweight, high-performance, hand-held Fluke
FLIR infrared cameras.
10What kind of problems can Infrared Thermography
detect?
- Infrared Thermography has been proven to find,
- quantify, and document problems caused by
- Electrical Mechanical
Building - Faulty components Shaft misalignment
Moisture infiltration
of roof - Poor connections Worn bushings
bearings Air infiltration or
exfiltration - Corrosion Improper
tension of belts pulleys Areas of
potential mold growth - Contamination Over or under
lubrication Air circulation
and distribution - Load imbalances Gear box anomalies
Leaky or clogged
pipes - and much more Excess friction
and much more -
11Electrical Inspections
The anomaly, or hot spot, indicates a probable
problem with the disconnect.
12Electrical Inspections
Poor connection to common buss bar in circuit
breaker panel.
13Electrical Inspections
Poor fuse to fuse clip connection.
14Electrical Inspections
Probable loose or corroded connections.
15Mechanical Inspections
Infrared Image Bearing Over Lubrication
Digital Image
16Mechanical Inspections
Infrared Image Misaligned drive between motor
and pump
17Roof Inspection
Moisture build up under tar and gravel roof.
18Building Envelope
Skin temperatures on furnaces, boilers, reactors
and storage tanks of all types can be monitored
easily using infrared thermography
Missing insulation!
19Subsurface Leaks
Leak in radiant heating system under a concrete
pad.
20Structural/Refractory
Checking for missing refractory lining in an oil
refinery cat. cracker.
21What information will be provided after the
inspection is complete?
- You will receive an easy-to-understand report
that provides thermographic images, digital
images, and temperature information to help you
determine what needs corrective action and what
is operating normally. - The written report will include an inventory of
all anomalies, and follow-up documentation of
past problems. This information is presented in a
logical order so that your engineer can formulate
an effective repair plan.
22A Sample Report
- Summery Page
- States the scope of the
- inspection.
- Lists the number of
- locations inspected.
- The total number of
- items inspected.
- A breakdown by
- severity of the
- anomalies found.
- The number of
- anomalies corrected
23A Sample Report
- Inventory Page
- Provides a complete list
- of all items inspected by
- location
- Pass / fail notation
- Tested / not tested notation
- Thermographic page
- number of failed items
- Color coded for easier
- interpretation
24A Sample Report
- Prioritized List
- Ranks the anomalies
- in order of their severity
- as defined by the Delta T
- or increase of temperature
- over a like component under
- similar load and environmental
- influences.
- This is provided to aid in the
- scheduling of corrective actions.
25A Sample Report
- Thermographic Page
- Includes both the digital
- and matching thermogram.
- Provides relevant
- temperature data for the
- regions of interest.
- Provides possible causes
- and recommended actions.
- Fully describes location,
- equipment id, barcode,
- severity, and inspector id.
26What will Delmarva Infrared Services need to
inspect your facility?
- Job site preparation - Clear and safe access to
work area - Equipment preparation - Equipment to be in normal
operation - Designated Employee - To open and close equipment
panels
27- Delmarva Infrared Services has experts eager to