DAYLIGHTING - PowerPoint PPT Presentation

1 / 36
About This Presentation
Title:

DAYLIGHTING

Description:

FOOT-CANDLES FOR THE TEST PERIOD. HYPOTHESIS 2: THE AVERAGE FOOT-CANDLES MEASURED ... HYPOTHESIS 3: ALL ROOMS FAILED TO AVERAGE 20-100 FOOT-CANDLES EXCEPT THE ... – PowerPoint PPT presentation

Number of Views:685
Avg rating:3.0/5.0
Slides: 37
Provided by: Kim493
Category:

less

Transcript and Presenter's Notes

Title: DAYLIGHTING


1
DAYLIGHTING
KENT STATE UNIVERSITY
  • ENVIRONMENTAL TECHNOLOGY III
  • ADIL SHARAG-ELDIN, PH.D.
  • SPRING 2004

KIM ENGELHART
2
OBJECTIVE
THE OBJECTIVE OF THIS PROJECT IS TO STUDY
DAYLIGHTING IN A RESIDENTIAL SETTING AND TO APPLY
THE KNOWLEDGE LEARNED TO CURRENT AND FUTURE
DESIGNS.
3
THE SPACE
1000 SQUARE FEET LAKE VIEW FACES EAST LOT
40x270 TREES AND VEGETATION ON SOUTH SIDE
FIRST FLOOR PLAN
4
ANALYSIS OF SPACE
RATIO SQUARE FEET OF GLAZING TO SQUARE FEET OF
FLOOR
FIRST FLOOR PLAN
5
HYPOTHESIS
HYPOTHESIS 1 THE ROOM WITH THE RATIO OF 14 WILL
PROVIDE THE LARGEST AVERAGE FOOT-CANDLES FOR THE
TEST PERIOD. HYPOTHESIS 2 THE AVERAGE
FOOT-CANDLES MEASURED IN THE HALLWAY WILL RANGE
0-5 FOR THE TEST PERIOD. HYPOTHESIS 3
DAYLIGHTING IS IN THE MODERATE RANGE OF 20-100 IN
ALL SPACES (ILLUMINATING ENGINEERING SOCIETY OF
NORTH AMERICA)
FIRST FLOOR PLAN
6
RESEARCH METHOD
.
A 3x3 GRID WAS PLACED OVER THE PLAN READINGS
WERE TAKEN AT EVERY POINT EVERY HOUR FROM 600
A.M. UNTIL 700 P.M. ON MARCH 31, 2004 ALL
READINGS WERE TAKEN AT 36 ABOVE THE FLOOR WITH
THE MINOLTA ILLUMINANCE METER ALL BLINDS WERE
OPEN AND NO ARTIFICIAL LIGHTING WAS SUPPLIED. THE
SKY WAS PARTLY TO MOSTLY CLOUDY THE ENTIRE DAY
(81 OF DAYS IN AKRON ARE PARTLY TO MOSTLY
CLOUDYWEATHER OF U.S. CITIES)
FIRST FLOOR PLAN
7
RESEARCH RESULTS
.
600 A.M.
8
RESEARCH RESULTS
.
700 A.M.
9
RESEARCH RESULTS
.
800 A.M.
10
RESEARCH RESULTS
.
900 A.M.
11
RESEARCH RESULTS
.
1000 A.M.
12
RESEARCH RESULTS
.
1100 A.M.
13
RESEARCH RESULTS
.
1200 P.M.
14
RESEARCH RESULTS
.
100 P.M.
15
RESEARCH RESULTS
.
200 P.M.
16
RESEARCH RESULTS
.
300 P.M.
17
RESEARCH RESULTS
.
400 P.M.
18
RESEARCH RESULTS
.
500 P.M.
19
RESEARCH RESULTS
.
600 P.M.
20
RESEARCH RESULTS
.
700 P.M.
21
RESEARCH RESULTS
.
INTERIOR PHOTOGRAPHS OF DAYLIGHT IN MAIN LIVING
SPACE(YELLOW 16)
FIRST FLOOR PLAN
22
RESEARCH RESULTS
.
INTERIOR PHOTOGRAPHS OF DAYLIGHT IN MAIN LIVING
SPACE(YELLOW 16)
800 A.M.
23
RESEARCH RESULTS
.
INTERIOR PHOTOGRAPHS OF DAYLIGHT IN MAIN LIVING
SPACE(YELLOW 16)
900 A.M.
24
RESEARCH RESULTS
.
INTERIOR PHOTOGRAPHS OF DAYLIGHT IN MAIN LIVING
SPACE(YELLOW 16)
1000 A.M.
25
RESEARCH RESULTS
.
INTERIOR PHOTOGRAPHS OF DAYLIGHT IN MAIN LIVING
SPACE(YELLOW 16)
1100 A.M.
26
RESEARCH RESULTS
.
INTERIOR PHOTOGRAPHS OF DAYLIGHT IN MAIN LIVING
SPACE(YELLOW 16)
1200 P.M.
27
RESEARCH RESULTS
.
INTERIOR PHOTOGRAPHS OF DAYLIGHT IN MAIN LIVING
SPACE(YELLOW 16)
100 P.M.
28
RESEARCH RESULTS
.
RATIO OF GLAZING TO FLOOR AREAS AVERAGE
FOOT-CANDLES FOR TESTING PERIOD
29
RESEARCH RESULTS

.
THE HIGHEST FOOT-CANDLES OCCURRED FROM 1100
A.M. TO 200 P.M.
1100 A.M.
1200 P.M.
100 P.M.
200 P.M.
30
CONCLUSIONS
HYPOTHESIS 1 DISPROVED THE AVERAGE FOOT-CANDELS
WAS NOT THE HIGHEST IN THE GREEN
SPACE. HYPOTHESIS 2 THE HALLWAY RANGE FOR
AVERAGE FOOT-CANDELS DID NOT REACH ABOVE 5. THE
ACTUAL RANGE IS 0-5 FOOT-CANDELS. HYPOTHESIS 3
ALL ROOMS FAILED TO AVERAGE 20-100 FOOT-CANDLES
EXCEPT THE MAIN LIVING AREA(YELLOW). THE
HIGHEST FOOT-CANDELS RECORDED OCCURRED NEAREST TO
THE TWO, THREE-SECTIONED WINDOWS.
AVERAGE FOOT-CANDLES FOR TESTING PERIOD
31
CONCLUSIONS
THE NEW PLAN WILL ELIMINATE THE INTERIOR
HALLWAYAND MOST OF THE SOUTH FACING GLAZING. A
SECOND STORY WILL BE ADDED AND WILL INCORPORATE A
MASTER SUITE AND ONE BEDROOM WITH FULL BATH.
NINE FOOT CEILINGS WILL ALLOW BETTER DISTRIBUTION
OF DAYLIGHTING.
EXSITING FLOOR PLAN PROPOSED FLOOR PLAN
32
STUDY MODEL

EAST ELEVATION
NORTH ELEVATION

WEST ELEVATION
SOUTH ELEVATION
33
STUDY MODEL


SUN PATH DIAGRAM, 40 DEGREES LATITUDE
34
STUDY MODEL


SUN PATH DIAGRAM, 40 DEGREES LATITUDE
35
STUDY MODEL

EVENING SUN-JUNE

MORNING SUN-JUNE
36
STUDY MODEL

EVENING SUN-JUNE

VIEW FROM PROPOSED SECOND FLOOR MASTER SUITE
BALCONY(TAKEN FROM ROOF-TOP)
Write a Comment