TOPIC 4
  • BEHAVIORAL ASSESSMENT MEASURES

2
The Audiometer
  • Types
  • Clinical
  • Screening

3
The Audiometer
  • Components
  • Pure tone oscillator
  • Attenuator
  • Interrupter switch
  • Output transducer
  • Headphones
  • Supra-aural
  • Insert
  • Bone conduction vibrators
  • Forehead
  • Mastoid
  • Loudspeakers

4
Audiometer Components
5
Pure Tone Audiometry
  • The aim of pure tone audiometry is to establish
    hearing threshold sensitivity across the range of
    audible frequencies important for communication

6
The Audiogram
7
Air Conduction vs Bone Conduction Testing
  • Air conduction tests the entire auditory system.
    Bone conduction bypasses the conductive
    mechanism, so it tests only the inner ear.

8
Audiometric Symbols
  • Unmasked air conduction
  • Left ear
  • Right ear
  • Unmasked bone conduction
  • Left side
  • Right side
  • Masked air conduction
  • Left ear
  • Right ear
  • Masked bone conduction
  • Left ear
  • Right ear
  • No response

9
What the Audiogram Says About the Impairment
Within normal limits
Mild
Moderate
Severe
Profound/deaf
10
What the Audiogram Says About the Impairment
  • The configuration of the hearing loss
  • Flat
  • Rising
  • Sloping

11
What the Audiogram Says About the Impairment
  • The degree of hearing loss
  • The configuration of the hearing loss
  • The type of hearing loss
  • Conductive
  • Sensorineural
  • Mixed

12
Establishing a Pure Tone Audiogram
  • Establish which is the better ear and test first
  • Start air conduction testing at 1000 Hz
  • Begin at 30 dB HL. If there is no response,
    increase intensity in 20 dB steps until you see a
    response
  • Follow the down in 10, up in 5 rule

13
ASHA Procedure
  • Hypothetical threshold search for a listener
    whose threshold is 35 dB HL. A indicates the
    listener heard the presentation, and a - shows
    the listener didnt hear the tone. Notice that
    the hearing level of a trial is raised by 5 dB
    following a - and is lowered by 10 dB following a
    .

14
Establishing a Pure Tone Audiogram
  • After several crossings of the same intensity,
    pick threshold as an intensity where 50 of the
    time the listener responds correctly
  • Move to 2000 Hz, 3000 Hz, 4000 Hz, and 8000 Hz
    (as a minimum)
  • Pick up the low frequency (500 and 250 Hz) tones
  • Repeat for the other ear

15
Speech Audiometry
  • Uses
  • Sensitivity for speech
  • Speech awareness threshold
  • Speech reception threshold
  • Pure tone cross check
  • Speech recognition
  • Differential diagnosis
  • Central auditory processing
  • Estimate of communicative function

16
Speech Audiometry
  • Materials
  • Types
  • Nonsense syllables
  • Monosyllabic words
  • Spondaic words
  • Sentence tests

17
Speech Audiometry
  • Relationship of redundancy of informational
    content and sensitivity to the effects of hearing
    loss on three types of speech recognition
    materials

18
Speech Audiometry
  • Intrinsic redundancy
  • Extrinsic redundancy
  • Frequency--low pass filtering
  • Time--time compression
  • Intensity--high presentation levels
  • Competition--speech in noise
  • Binaural--dichotic measures

19
Speech Audiometry
  • Relationship of intrinsic and extrinsic
    redundancy to speech recognition ability in
    normal listeners

20
Speech AudiometryClinical Methods
  • Speech thresholds
  • Speech Reception threshold
  • Start audible
  • Present four spondees
  • Calculate percent-correct response
  • Follow down in 10, up in 5 rule
  • Stop at an intensity that provides 50

21
Speech AudiometryClinical Methods
  • Speech thresholds
  • Speech Reception threshold
  • Speech Awareness threshold
  • Word recognition testing

22
Word Recognition Testing
  • Things to consider
  • Materials
  • Goals?
  • Amount of extrinsic redundancy you need?
  • Language level?
  • Other special needs or considerations?

23
Word Recognition Testing
  • Things to consider
  • Materials
  • Presentation
  • Monaural?
  • Binaural?
  • Headphones?
  • Sound field?

24
Word Recognition Testing
  • Things to consider
  • Materials
  • Presentation
  • Presentation Level
  • Maximal ability
  • Normal conversational level

25
Speech Audiometry
  • Interpreting speech discrimination results.
    Typical results based on disorder site

26
Other Behavioral Measures
  • Uses
  • To determine a functional or exaggerated hearing
    loss
  • To provide additional information necessary to
    fit amplification
  • To determine the presence of recruitment and
    adaptation