Title: CSeries Presentation Feb 2002
1C Series
C - SERIES ECCENTRIC DISC PUMPS
Feb. 2002
2C Series
STAINLESS STEEL
DUCTILE IRON
3Product Features
- SEALLESS
- no mechanical seals
- no magnets
- no rubber or PTFE diaphragms
- HERMETICALLY SEALED
- NO BEARING IN LIQUID
- CAN RUN DRY for 3 to 5 minutes
- MULTIPHASE (GAS / LIQUID MIXTURES)
- HIGH VACUUM 29 Hg
- DEVELOPS 22 PSIG (DRY), 50PSIG WET
- EXTREMELY LOW SLIP, SELF- ADJUSTING
4Product Features
- EXCELLENT CLEAN IN PLACE (CIP)
- WILL PASS SOLIDS
- VERY LOW INTERNAL VELOCITY
- EXTREMELY LOW SHEAR
- 3A CERTIFIED
- MULTIPLE PORT ARRANGEMENTS
- MULTIPLE FLANGE SELECTION
- SPECIFIABLE
- AVAILABLE IN BOTH 316L SS DUCTILE IRON
DUCTILE IRON ARE ONLY AVAILABLE IN SIZES C4,
C8, C12 C18
5Performance Characteristics
Speed C1 - 1000 rpm C2 - 1000 rpm C4 - 750
rpm C8 - 750 rpm C12 - 500 rpm C18 - 500
rpm C24 - 450 rpm C36 - 450 rpm
Flow C1 - 1 m3/h (4 gpm) C2 - 2 m3/h (9
gpm) C4 - 4 m3/h (18 gpm) C8 - 8 m3/h (35
gpm) C12 - 12 m3/h (53 gpm) C18 - 18 m3/h
(80 gpm) C24 - 24 m3/h (105 gpm) C36 - 36
m3/h (158 gpm)
Maximum Working Pressure C1 - 9 Bar (130
psi) C2 - 9 Bar (130 psi) C4 - 9 Bar
(130 psi) C8 - 5 Bar (72.5 psi) C12 - 9
Bar (130 psi) C18 - 6 Bar (87 psi) C24
- 9 Bar (130 psi) C36 - 6 Bar (87
psi)
Maximum Temperature Std. Models - 800 C (1760 F)
/ HT Models - 1500 C (3020 F)
Viscosity 2000 cSt (10000 SSU) - 3000 cSt
(14000 SSU) depending on model.
6C Series
7C Series
Stainless Design Benefits
- SEALLESS - No Mechanical Seal, Magnetic Drives or
Packing. - SELF ADJUSTING - Maintains the delivery/ pressure
performance over time with automatic
disk/cylinder wear adjustment. - DRY PRIME - Self priming and able to dry-run for
up to 10 minutes. Capable of complete line
stripping of suction and discharge pipes of
residuals. - 3A APPROVED - 3A and EHEDG (European Hygienic
Equipment Design Group) certification, All wetted
parts have a 0.8 Ra finish. - CIP - Pump is designed to be flushed and cleaned
in place without disassembly and has the
capability to be completely drained. - HIGH VOLUMETRIC EFFICIENCY - Pump is able to
maintain a constant flow rate at a given
viscosity throughout its pressure range. - LOW SHEAR - Very careful handling of the product
(Ultra low agitation and shear)
8C Series
Stainless Design Benefits
- 316L Stainless Steel
- No Mechanical Seals
- No Magnets
- No rubber or PTFE diaphragms
- 3A Certified
- Self Adjusting
- High Volumetric Efficiency
- CIP
- Self-Priming Draining
- Multiple port arrangements
- Multiple flange selection
9Sanitary Approval
10C Series Stainless ina Sanitary Application
11C Series Stainless inan Industrial Application
12C Series
Ductile Iron Design Benefits
- Sealless
- No Mechanical Seals
- No Magnets
- Hermetically Sealed
- Integral Relief Valve
- (ductile iron version only)
- ANSI Compatible Flanges
- Self Adjusting
- Self-Priming Draining
- High Volumetric Efficiency
13C Series Ductile Iron onan Industrial Application
14Typical Applications
- FOOD INDUSTRY
- SAUCES DRESSINGS
- MAYONAISE
- MUSTARD
- MARGARINE
- CHOCOLATE
- JAM JELLIES
- ICE CREAM YOGARTS
- CANNED FRUITS
- GLUCOSE FRUCTOSE
- SOFT 10 JUICE DRINKS
- FLAVORINGS
- BABY FOOD
- SYRUPS HONEY
- ICINGS
- BEVERAGE PRODUCTS
- HEALTHCARE / COSMETICS
- TOOTHPASTE
- MOUTHWASH
- CREAMS
- HAIR CARE PRODUCTS
- SHAMPOO
- LOTIONS
- NAIL POLISH
- PHARMACEUTICAL
- CREAMS OINTMENTS
- BLOOD
- PETROLEUM JELLY
- GLYCERINE
- INSULIN
15 Typical Applications
- CHEMICAL INDUSTRY
- ACETATES
- ACETONE
- ACIDS
- ACRYLIC
- ADDITIVES
- ADHESIVES
- ALKALIS
- AMMONIA
- BITUMIN
- CAUSTIC
- CHEMICALS
- CLEANING SOLUTIONS
- DYES
- EMULSIONS
- ENAMELS
- FERTILIZERS
- FILM BASE
- INKS
- ISOCYANATE
- LATEX
- PAINTS COATINGS
- PAPER COATINGS
- PHOTO GELS EMULSIONS
- POLYMERS POLY URETHANE
- PVC
- RESINS
- SEALERS
- SOLVENTS
- VARNISH
- VINYL
- WAX
16C Series
How Does It Work?
17C Series
Drive shaft machined on 4 different planes
18Shaft
C Series
19Bellows
C Series
20C Series
21C Series
RADIALLY SELF-ADJUSTING
Max clearance
.04
mm
shaft
cylinder
radial spring loading
disc
Radial spring maintains close tolerance between
cylinder/disc
22C Series
AXIALLY SELF-ADJUSTING
shaft
hub
axial spring loading
Spring action pulls the disc towards the cylinder
23C Series
Radial SpringSet
Axial SpringSet
24C Series
General Disassembly
25C Series
1. Remove nuts 2. Remove bolts
26C Series
1. Remove spacer and seal rings
27C Series
Using TWO wrenches, loosen the nut
NOTE DO NOT ALLOW THE DISC TO ROTATE AS YOU
WILL DAMAGE THE BELLOWS!
28C Series
Remove the nut and seal ring
29C Series
Remove the disc and cylinder
30C Series
Remove the 2 seal rings
31C Series
Remove Suction HousingTie Bolts
Remove the nuts and bracket bolts
32C Series
1. Gently tap on the back of the bracket (104) 2.
Release the intake tube
NOTE DO NOT STRIKE THE BELLOWS AS DAMAGE WILL
OCCUR!
33C Series
General Reassemble
34C Series
1. Rotate the intake tube to desired location
NOTE DO NOT STRIKE THE BELLOWS AS DAMAGE WILL
OCCUR!
35C Series
Insure the beveled sides of the cylinder are in
alignment with the hole in the disc
36C Series
Insure the notch in the cylinder aligns with the
pin in the bracket
37C Series
(Another view)
38C Series
Install the seal ring and the nut
39C Series
Using TWO wrenches, tighten the nut
NOTE DO NOT ALLOW THE DISC TO ROTATE AS YOU
WILL DAMAGE THE BELLOWS!
40C Series
Install the first seal ring, the spacer and the
second seal ring
41C Series
Install the bolts and nuts Torque the nuts in
accordance with the IOM
42C Series
Relief Valve Iron Pump Only
43C Series
Relief Valve Function
44C Series
Adjust relief valve setting by removing cap. Turn
adjusting nut down to increase pressure
setting. Turn adjusting nut up to decrease
pressure setting.
45C Series
46C Series
Cylinder Disc Dimensions
47C Series
Minimum Dimensions
A
B
If dimensions are less than minimum, a new
assembly is required.
48C Series
Transmission Lubrication
49C Series
It is recommended the transmission lubricant be
changed every 5000 hours of operation Drain
transmission by removing drain plug and seal
washer
50C Series
Replace plug and fill will appropriate grade of
castor oil. Quantity is based on model (See IOM)
51Bearing Lubrication
Standard Oil is ISO VG 68 Castor Oil Viscosity
Range from 8 cst _at_ 110C(230F) to 5500 cst _at_ 0C
(32F) Other Lubrication Oil Can Be Provided With
Blackmer Approval
52Disk Material IsActeon NON-Galling Metal
- COMPOSITION
- Carbon 0,05 maxi
- Nickel 70
- Chrome 13
- Molybdenum 3
- Excellent CORROSION RESISTANCE
- Similar to Waukesha Alloy 88
53The General Application of C Series Pumps
54C Series
Clean In Place
55C Series
CIP Internal Action
Pressure is introduced to the back of the disc.
When pressure overcomes the spring the disc moves
away from the cylinder
56C Series
This allows cleaning solutions to pass through
the pumping chamber
disc movement due to flush pressure
57Clean In Place
Self Cleaning Or Cleaned by an External
Circulation Pump
The C Series Has a Low Pressure Drop Through the
Pump and May Not Need to Be Bypassed to CIP
Unlike Our Competitors The C Series has No Close
Clearances Smallest Clearance is 1/16 inch
58CIP Continued
- The disk and cylinder react as a semi-open valve
and allows a large flow to pass through the pump. - CIP Example Flow at 40 GPM (10 m3/hr) with a
pressure at suction side of 14 psi (1 bar)
pressure loss in the pump 11.6 psi (.8 bar).
Blackmer will provide pump pressure drop data
for CIP Applications
59C Series Application Criteria
Max. Operating Conditions
60C Series Application Criteria
Suction Conditions
Important when NPSHA NPSHR Suction Pressure in
Normal Operation should not exceed 14.5 Psig and
should not exceed 43 Psig during CIP Viscosity
Limits of 3000 cst. (Higher with Factory
Approval) Particle Size, Lubricity or Abrasive
Nature of Liquid Need to be Considered when
Sizing Pump
61Suction PressureLimitations
CIP Mode Maximum 43 Psig (3 bar)
Normal Operation Maximum 14.5 Psig (1
bar)Suction
Bellows acts asa pressureretaining element
62Pump Life Expectancy
Blackmer has C Series Pumps running for MORE
THAN 24,000 HOURS CONTINUOUSLY at maximum
pressure and temperature and they are still
operating to date!
63Extremely Low Slip
C Series
Gear
C Series 2 Slip Gear 5 Slip
Slip is basedon 10 cst
PSI
64Low Slip
Low Slip Between the Disk and CylinderGives the
C the Ability to Create High Vacuumand Excellent
Gas Compression
Discharge Pressure on the Disk Causes Low Slip
65The Sizing Program
Vacuumand Compression
66Self Compensating Holds Efficiency
Blackmer
Gear
Blackmer Will Stay On The Job
67C Series
15 TiO2 Disk 1,000 hours
68C Series
15 TiO2 Disk 1,000 hours
69Motion of the Cylinder and DiskCauses Very Low
Internal Velocity
70Velocities Within Pumps
71Eccentricity of a C Series
C1 / C2 e 4.5 mm (.177 inches) C4 / C8
e 6 mm (.236 inches) C12 / C18 e 10 mm
(.394 inches) C24 / C36 e 13.5 mm (.531
inches)
72Velocity Example
10 GPM _at_ 100 PSIViscosity 1000 cps
C Series Size 4 Turning 420 RPM Velocity of Disk
.87 ft/sec
Waukesha Size 18 Turning 340 RPM Velocity of
Rotor 3.15 ft/sec Based of a rotor diameter of
4.25 inches
Viking Gear Pump Size K4124A Turning 220
RPM Velocity of Main Gear 3.84 ft/sec Based of
a gear diameter of 4 inches
Blackmer Progressing Cavity Pumps 2TL6 Turning
280 RPM Velocity of Rotor .32 ft/sec Based of
a rotor diameter of 2.78 inches
Blackmer NP 1.5 Turning 138 RPM Velocity of Rotor
2.76 ft/sec Based of a rotor diameter of 4.6
inches
73C Series
Viscosity Limit is 3,000 cst
Disk Centersin CylinderPump ActionIs Reduced
Greater Viscosity Can Be Pumped WithBlackmer
Approval
74Extremely Low Shear
Shear Rate For All C Series
Lower Than Circumferential Piston Lower Than
Lobe Lower Than Gear
75System Viscosity
Piping Shear RateMetric
76System Viscosity
Piping Shear RateEnglish Units
77Product Shear Rate Curve
78C Series Selection
79System Viscosity Changes With Shear
C12-I rated 35 GPM (8 m³/hr) _at_ 45 PSI (3 Bar) See
Shear Rate Curve
10000 cps
1000 cps
2 in. (DN50)
3.15 in. (DN80)
4000 cps
2000 cps
80Actual Net Inlet Pressure RequiredBy a C Series
C4 Pump Pressure (psi) 30.00 30.00 Speed
(rpm) 304 304 Flow rate (gpm) 30.00 30.00 Pow
er (HP) 1.78 1.95 Viscosity (cst) 1 1000
NPSH (psiA) 1.24 16.69 Dry vacuum
(psi) -10.79 -10.80 Wet vacuum
(psi) -13.51 -13.51 Dry Compressor
(psi) 29.55 29.58 Wet Compressor
(psi) 52.08 52.13
81Maximum Particle Sizes
C1 / C2 1 mm C4 / C8 2 mm C12 / C18 3 mm C24
/ C36 3 mm
82Heating Jacket Is Part of the Casting It is
machined and sealed as an option.
Iron VersionOnly
Heating Jacket
83C Series
Applications
84C Series
APPLICATION 1
APPLICATION 1
-
C12-I
pump
Pumped product
Mayonnaise,
Ketchup,
Sauces
speed
140 rpm
-
15 to 1200
cps
( 70 to 5500 ssu)
Viscosity
2.
2 Kw (2.95 hp)
power
-
Flowrate
.4 to 4.5 m
3
/h (1
.76
to
19.8 gal/
min)
-
Working pressure
3.0 bar
(43
.5
psi)
SAUCE
KETCHUP
MAYONNAISE
FILLING
MACHINE
C12I
Why do they use
C12I
-
Excellent
volumetric efficiency
regardless of
viscosity.
- Good
self draining.
-
All
wetted parts
are
stainless
steel.
-Ability to Clean
85C Series
APPLICATION
2
APPLICATION
2
-
2-C4s
pumps
Pumped
product
Méthacrylonitrile
(dangerous solvent)
speed
700 rpm
-
cps
(
ssu)
Viscosity
1.5
Kw (2.0 hp)
power
-
Flowrate
3.8 m
3
/h (16
.7 gal/
min)
-
Working pressure
3.0 bar (43
.5
psi)
PRESSURE
GAUGE SWITCH
FOR
SERVO
CONTROL STARTING
2
- C4 PUMP
WITH
BYPASS
FEED
TO
FACTORY
Why do they use C4
- Replaced magnetic driven
pump
(major damage
occurred to the magnetically driven pump when
it was
run dry
).
- Required sealess pump as the product is
sensitive
to
contact with
Air (crystal formations).
86C Series
APPLICATION
3
APPLICATION
3
-
Pumped
product
Sulfonic acid
C12-I
Pump
-
Viscosity
1
cst (30 ssu)
speed
260 rpm
power
1.5
Kw (2.0 hp)
-
6.0 m
/h
26
.4 gal/
min)
Flowrate
3
(
-
6.0 bar (87
psi)
Working pressure
-
Ambient temperature
SULFONIC ACID
C12I
Why do they use
C12I
- Replace gear pump.
- Problem
with
pump leaking.
- Hazardous
maintenance
with
gear
pump.
87C Series
APPLICATION
4
APPLICATION
4
C12-I
pump
-
Pumped product
Varnish UV, Solvent
speed
100
to
300 rpm
-
Viscosity
1
to
3000
cst (30 to 14000 ssu)
power
1.5
Kw (2.0 hp)
-
Flowrate
3 to 7.9 m
3
/h (13
.2
to
35 gal/
min)
-
Working pressure
2.0 bar (29
psi)
containers
-
122
F
to
158
F
Temperature
0
0
Filling
Area
(50
C to 70
C)
0
0
REACTOR
C12I
Why do they use C12I
Replaced
lobe
pump.
-
- Polymerization
of
the varnish
occurred between the
seal
faces.
- Product is
very sensitive
to contact with
air.
Drums
- Product
hardened with overheating
Galling Sticking ( between end-plate, front
cover lobes
).
- The
liquid must be constantly
renewed.
Therefore,
it is necessary to
avoid
slip
dead
zone.
88C Series
APPLICATION
5
APPLICATION
5
C4-A
pump
-
Pumped product
ink
( before pulverizing)
speed
80
to
200 rpm
power
1
.5
Kw (2.0 hp)
-
Viscosity
300
to
1000
cps (1400 to 4800 ssu)
-
.5 to 2.0 m
/h (2
.2
to
8.8 gal/
min)
Flowrate
3
-
3.0 bar (43
.5
psi)
Working pressure
-
Ambient temperature
PULVERIZER
INK
C4A
Why do they use C4A
-
Replaced
hose
pump.
- Hose rupture
due to accidental
over-pressure.
- Protection
of C4A with
internal
bypass.
89C Series
APPLICATION
6
APPLICATION
6
-
C4-A
pump
ink
Pumped product
( after pulverizing)
speed
150
to
450 rpm
-
100
to
2000
cps (480 to 9600 ssu)
Viscosity
power
1.5
Kw (2.0 hp)
-
Flowrate
1.0 to 3.0 m
/h
(
4
.4
to
13.2 gal/
min)
3
-
Working pressure
3.0 bar (43
.5
psi)
-
Ambient temperature
CONTAINERS
INK
C4A
FILTER
Why do they use C4A
- Replaced
gear
pump.
- Lower maintenance
costs
(dont need
to change mechanical seal
).
- More efficient pump and system
cleaning.
.
- Less unscheduled downtime (don t need to change
mechanical seal)
90C Series
APPLICATION
7
APPLICATION
7
-
Pumped
product
vinegar
C12-I
pump
400 rpm
speed
-
1
cps (30 ssu)
Viscosity
power
4
Kw (5.36 hp)
-
Flowrate
10 m
3
/h (44
gal/
min)
-
Working pressure
3.0 bar (43
.5
psi)
-
Ambient temperature
Buffer zone before
conditioning
VINEGAR
Filter
Tank
Length 25m
C12I
Why do they use C12I
-
Replaces
lobes
pump.
- Regular
flowrate
due to low pump slip (regardless of
filter pressure).
- Excellent pump suction on long inlet
piping
.
91C Series
APPLICATION
8
APPLICATION
8
-
Pumped
product
Liquid Cake mix
C4-I
pump
speed
390 rpm
-
Viscosity
3000
cps (14000 ssu)
power
1.5
Kw (2.0 hp)
-
1.5 m
/h (6
.6 gal/
min)
Flowrate
3
-
Working pressure
6.0 bar (87
psi)
-
Temperature
63.3
C (146
F)
0
0
O 50
ICE CREAM CAKE MANUFACTURER
O 50
C4I
Cooling system
Why do they use C4I
-
Replaced
lobe
pump.
- No mechanical seal.
92C Series
APPLICATION
9
APPLICATION
9
-
Pumped product
resin
, paint ( water base), varnish
C4-I
pump
speed
420 rpm
-
Viscosity
100 up to 4000
cps (480 to 19000 ssu)
3
Kw (4.0 hp)
power
-
Flowrate
3.0 m
3
/h (13
.2 gal/
min)
-
5.0 bar (72
.5
psi)
Working pressure
-
Ambient
temperature
PAINT
MANUFACTURER
FOR
AUTOMOTIVE
FILTER
C4I
DRUMS
Why do they use C4I
-
Replaced Mouvex
A
Series (not sealless).
- All
stainless
steel.
- Improved self
-
priming.
93C Series
APPLICATION
10
APPLICATION
10
C12-I
pump
-
Pumped product
Acrylic
base
speed
420 rpm
power
3
Kw (4.0 hp)
-
Viscosity
600
cps (2900 ssu)
-
Flowrate
10 m
3
/h (44
gal/
min)
-
Working pressure
3.0 bar (43
.5
psi)
-
temperature
40
C
(
104
F)
0
0
REACTOR
C12I
Why do they use C12I
-
Replaced
centrifugal
pump.
- Problems
with mechanical
seal.
94C Series
APPLICATION 11
Pumped product Molasses and Honey
Pump C4-I
Viscosity 3000 to 7000 cps
Flowrate 2 - 7 GPM With VFD
Working pressure 50-75 psi
Temperature Ambient
Other Ingredients
Honey
Molasses
Mix Tank
Why do they use C4I No Mechanical Seal Able
to Clean
95C-Series Support Literature
- Installation, Operation Maintenance Manual
- Dimensional Pages
- Price Page
- Curves
- Materials of Construction Pages
- Parts Pages
- Applications Form
- Brochure
- CD with Flash, Brochure, Applications, Selection
Program
96Blackmer 1809 Century Avenue, S.W. Grand Rapids,
Michigan, USA 49503 Phone (616) 475-9362 Fax
(616) 248-9203 E-mail blackmer_at_blackmer.com web
www.blackmer.com